§ 2.6 — Mixed-Use Districts
Code of Civil and Criminal Ordinances of the City of Irving, Texas (Irving Code of Civil and Criminal Ordinances, Charter and Land Development Code current through legislation adopted September 24, 2026 (eCode360 publication IR6873, scraped 2026-11-17)) · Irving Land Development Code § 2.6
Corpus is an independent public-information project, not the official City of Irving website. Stable reference: corpuslaw.us/code/a5e26e5c-2069-4c9f-9273-a5706554fea5
2.6: Mixed-Use Districts.
2.6.4 Planned Unit Development (PUD). a) Purposes: The purpose of a Planned Unit Development ("PUD") is to accommodate planned associations of uses developed as integral land use units such as industrial parks or industrial districts, offices, commercial uses, service centers, shopping centers, residential developments of multiple or mixed housing, including multi-family dwellings, single-family dwellings, townhouses or any appropriate combination of uses which may be planned, developed or operated as integral land use units whether by single owner or by a combination of owners. This zoning district shall be permitted for tracts of land not less than thirty (30) acres in area. b) Procedure: The stages or procedure for a Planned Unit Development shall be as follows: 1) The application for PUD zoning (Subsection c below). 2) The submission of a development plan (Subsection d below). c) Zoning of PUD districts: 1) Submission of application: Any person or corporation or group of persons having a proprietary interest in any property of thirty (30) acres or more may file an application for PUD zoning. 2) Data to accompany application: The application for PUD zoning shall include the following: a. Metes and bounds description of the overall tract with topographic information necessary to project the natural terrain and environmental character of the site. b. A written description of the existing and allowable land use surrounding the proposed PUD district. c. A written description of planning assumptions and projections relating the PUD to the overall community growth and planning goals. d. A plan indicating location of major and secondary thoroughfares, as proposed within the City Master Thoroughfare Plan. e. A categorical listing of the total acreage for each land use related to current zoning district designations or the specific purpose. The designated usage will not be assumed to establish the area requirements as established within the zoning district. All setbacks, height, and coverage will be determined by the approved final development plan. f. Indication by acreage or percentage of total development, all major areas planned for public or private common open space. g. All applications with gross land area of one hundred (100) acres or less shall submit a graphic plan of proposed land use. Applications with gross land area of more than one hundred (100) acres shall have the option of filing either a graphic plan or a perimeter plan indicating land use to a depth of three hundred (300) feet around the exterior of the total site. h. A written indication of the maximum number of residential dwelling units to be constructed within the total PUD district. 3) Staff review and recommendations: The technical staff shall, as soon as practical, issue a written report thereon to the planning and zoning commission, a copy of which shall be furnished to the applicant. 4) Planning and zoning commission hearing: The planning and zoning commission shall hold an advertised public hearing on any application for PUD zoning district prior to making its recommendation and shall report their recommendation to the city council in accordance with standard procedures for a change of zoning. 5) PUD Open space policy: All open space shall be provided at a minimum ratio of .01 acre for each residential unit. For single-family or townhouse land use, the open space may be calculated including front setback areas. Private ownership of these areas is permitted, subject to the following conditions: a. All private park areas shall have grounds and equipment maintained in an attractive manner comparable with the neighborhood. b. Private park areas must be committed to permanent open space by deed restrictions. d) Development plan: 1) Submission of development plan: After the granting of PUD zoning, and as the applicant desires to develop the PUD district, or any portion thereof, he shall submit a development plan to the department of community development. If the applicant so desires, separate development plans may be submitted at separate times for portions or sub-areas of the PUD. 2) Contents: The development plan shall contain the following information: a. A description of the area or sub-area included in the development plan by dimensions and bearings on a scaled drawing thereof, or accurate survey with topography grades of not more than five (5) feet. b. A general description of the surrounding area. c. Provisions for public or private streets, alleys, storm sewers, sanitary sewers, setbacks and utility easements. Adequate provisions shall be made for maintenance of municipal utilities on private property. All easements must be reflected on the development plan indicating the following information: location, type and size, along with the volume and page number where the easement is recorded with Dallas County Deed Records. d. Percentage or acreage of projected land uses either for the total area or sub-area consistent with the detailed land use as established in the zoning ordinance and referencing a specific zoning district and all relevant area requirements, including any variances requested for the use proposed. e. Designation and location of open space for total site or sub-area. f. Maximum number and type of residential dwelling units to be constructed in said area or sub-area. g. Anticipated development schedule. h. Protective and restrictive covenants, homeowners association charters, if any. i. Development plans must meet the following criteria to be approved: 1. The acreage of a designated land use must neither exceed the maximum acreage projected for such use in the application for PUD, nor be such that all the projected minimum acreages for all uses cannot be met. 2. Single-family detached uses will be allowed to exceed the projected maximum acreage in the application regardless of whether such use was allowed at all. Where single-family detached uses exceed the maximum acreage, such acreage shall be charged against any other usages, regardless of whether the minimum acreage requirements can be met, save and except that the minimum requirements for open space must be met. 3. Development plans for multi-family uses within the PUD districts shall be accepted and processed only in those PUD districts where such use is designated in a multi-family overlay district consistent with the future land use plan map of the comprehensive plan. The acreage and number of dwelling units shall be charged against the respective category for such use but shall not exceed the maximums set forth in the PUD zoning and further, that the minimum acreage requirement for multi-family uses need not be met. j. Applicant may elect to classify the development plan as a preliminary or final subdivision plat installment, provided all requirements of the subdivision ordinance are met. k. Upon the filing of an application for a development plan with the department of Planning and Community Development of the City of Irving, the applicant shall pay to the City of Irving a nonrefundable application fee in accordance with the most recent schedule of fees adopted by the city council to help defray the cost of the processing required by this ordinance. 3) Staff review: Upon submission of a development plan for a PUD or a sub-area thereof, the technical staff shall confer and consult with the applicant and may make recommendations to the landowner for amplification, deletion or modification thereof. After a full opportunity for consultation between applicant and the technical staff, the development plan shall be submitted to the planning and zoning commission for final action and approval. 4) Public notification of development plans: All development plans shall be advertised in the same manner as the standard procedure for a change in zoning before the planning and zoning commission. Such advertisement shall include, but not be limited to, notification of property owners within two hundred (200) feet of the development plan area no less than ten (10) days prior to the planning and zoning commission public hearing, and posting of the development plan area with signage in accordance with the timing and locational requirements of section 1.11.3 (Notice). A petition of opposition signed by the owners of property within two hundred (200) feet of the development plan area shall not mandate a three-quarter (¾) vote of the planning and zoning commission to approve the development plan. e) Appeals: In the event that the applicant or an owner or owners of twenty (20) percent of the land within the two hundred (200) feet notification area objects to any action of the planning and zoning commission in connection with a development plan, he/she may file with the zoning administrator a written objection to such action within ten (10) days of the planning and zoning commission action. An applicant or landowner who files such written objection shall have the right to present such objection to the city council. Public notice for an appeal shall be the same for the city council hearing as for the planning and zoning commission hearing. At such meeting, the city council shall review the decision of the planning and zoning commission and the objection filed, and take such action as it may deem appropriate. f) Amendment to PUD zoning: If the owner/applicant of a tract or lot within an area zoned PUD desires to change the conditions, perimeter tract designations or any other provision of the PUD, the owner/applicant may submit a request to amend the PUD regulations relative to the tract or lot. In order to protect the integrity of a PUD, changes to PUD zoning shall require additional procedural steps to ensure that all potentially affected parties are notified. The following steps are required in order to amend the PUD regulations relative to a particular property within a PUD. 1) Regardless of the land area of the tract or lot, the applicant shall submit a development plan which incorporates all the elements required by subsection 2.6.4(d) (Development Plan) of this ordinance, and a conceptual plan showing the proposed development's land uses, the approximate acreage of each land use, preliminary street and alley layout, and open space. The applicant shall also submit a detailed written description of the proposed land uses and development regulations, including other appropriate exhibits applicable to the proposed development, which may include, but not be limited to, specific land uses, lot area, setbacks and dimensional controls, lot coverage, density or floor area ratio, height restrictions, landscaping, screening, fencing and walls, building materials and colors, architectural style, open space, street and alley standards, provisions for utilities, signage, public use areas and amenities, other thematic elements, and proposed deed restrictions. Staff may request any or all of the above information, or any other information it deems necessary to assist in analyzing the request and preparing its report to the planning and zoning commission and city council. 2) For all such applications, the applicant shall also submit a written narrative which cites the specific provisions of the PUD zoning with which the proposed development plan does not comply, and how the proposed development plan will be more appropriate or compatible, or yield a higher public benefit relative to development allowed under the existing PUD requirements. 3) Staff will process and provide public notice of the request in accordance with the standard development plan application review process, except that (1) notification of the public hearings to consider the request shall be mailed to all property owners within four hundred (400) feet of the request property and all property owner associations of which the city is aware within the PUD, and (2) at least one (1) sign shall be posted at all entrances to the PUD within five hundred (500) feet of the request property, or as directed by the community development director or designee. In order to ensure compliance with (2) above, the applicant shall provide as part of the application a vicinity map showing all entrances into the PUD within five hundred (500) feet of the request property. 4) Since the proposed development plan constitutes a change in the zoning conditions of the property, the request shall be forwarded from the planning and zoning commission to the city council for final consideration. The requirements for a three-fourth (¾) affirmative vote for approval shall apply the same as for any other zoning request should twenty (20) percent or more of the property within two hundred (200) feet of the request site be represented by written opposition. 5) New development within the boundaries of such development plan must be in compliance with all requirements and standards of the approved development plan. 6) The application fee for an amendment to a PUD zoning shall be the same as for a detailed site plan (S-P-1) application for the same area. g) Disposition of previously approved project plans: 1) Project plans that were required and approved prior to July 21, 2005 shall remain in effect only in regard to the following specific provisions: a. If an approved project plan includes a specific requirement for landscaping, building materials, fencing or screening, parking, additional setback, hours of operation, lighting or any other site-specific development requirement that was established as part of the public hearing process before the planning and zoning commission and/or city council, and that exceeds the minimum standards of the approved development plan, such specific requirements shall remain in effect for the existing development and any change to the existing development. Any proposed changes to those specific requirements that exceed the minimum standards of the approved development plan that were established by the project plan are subject to the submittal and approval of a new development plan for the property covered by the previous project plan. b. If an approved project plan does not include a specific requirement for landscaping, building materials, fencing or screening, parking, additional setback, hours of operation, lighting or any other site-specific development requirement that was established as part of the public hearing process before the planning and zoning commission and/or city council, then any future development of that property including changes to the existing development need comply only with the standards established by the approved development plan. No project plan or revised/amended project plan shall be required prior to issuance of building permits for new development on such properties. 2.6.5 Transit-Oriented Development (TOD). a) Applicability: The transit oriented development district may be approved for any property within the corporate limits of the city any portion of which is generally within one-half (½) mile of any existing or proposed light rail transit line station or commuter rail transit line station. In addition, the planning and zoning commission and city council may consider on an individual basis any property within one-half (½) mile of an existing or proposed area personal transit (APT) system line station for inclusion into a transit oriented development. This district shall provide for the use of transit oriented development in accordance with the following guidelines. b) Purpose: The purposes of the transit oriented development district are to (1) provide guidelines for the development of property near rail transit line stations to maximize the transit opportunities and use of those facilities, and (2) provide an expedited approval process for developments that comply with these guidelines. c) Definition: For purposes of this section, transit oriented development shall be a development project that includes the following elements: 1) Moderate to higher density residential uses, 2) Located within a one-half (½) mile of an existing or proposed rail transit line station location, 3) Includes a mix of uses such as residential, retail, restaurant, office, hotel, entertainment, and open space, 4) Designed to encourage pedestrian activities, and 5) Shaped by transit relative to the mix and location of uses, building orientation, parking facilities, and density. d) Criteria for designation as a transit oriented development: The following criteria shall be used to determine whether a proposed development is considered to be transit oriented and thus eligible to receive transit oriented development district zoning: 1) The focus is on the overall development and the relationship to transit opportunities, not on the design of the individual components. 2) The transit station is shown to be a portal to the surrounding region, not just to the immediate area of the station. Connectivity to the surrounding area should be provided to attract others who can utilize both the transit service as well as the surrounding retail and office facilities. The streetscape going to and from the transit station is a key component. 3) The transit station should be a primary focus of the development with everything else radiating out from it, rather than pushed to the side. 4) There should be a master development plan of all the contiguous property owned by any one entity that shows both residential and nonresidential development with appropriate phasing. The master development plan should also show how the proposed transit oriented development relates and connects to adjacent properties to allow for continuation of streets, open spaces, pedestrian connections, utilities, and other features at the common property lines. 5) Every building does not need to be mixed-use - single use is acceptable as long as the overall development includes mixed-uses within short walking distances. 6) Buildings nearest the transit station and along the pedestrian access ways should have minimal setbacks and wide sidewalks which can accommodate outside dining, street vendors, public art, and sitting areas. Farther away from the transit station, traditional setbacks can be transitioned in. 7) The highest densities should be closest to the transit station, with densities gradually decreasing with more distance from the station. 8) Taller structures should be located nearest the transit station to provide the most convenience to and use of the transit options. 9) Open space, civic areas, and public amenities must be included in recognition of the higher densities which create the need for the open space. These can also serve as destination points within the development for residents. 10) Access and circulation for pedestrians as well as vehicles is provided throughout the development. The pedestrian environment should be attractive and comfortable with buildings framing public spaces, safe lighting, street trees, and awnings, canopies or other types of shade producing features. 11) Pedestrian connections and easy access to the transit station must be included and should not be overlooked when focusing on the buildings and other details. 12) Pedestrian access also includes bicycles, skaters, and small scooters. Walking and riding trails parallel to the rail should be provided whenever possible. 13) Not all pedestrian routes have to be parallel to streets - short cuts through open space or between buildings are acceptable. 14) Pedestrian underpasses and/or overpasses should be provided underneath or over all major thoroughfares to eliminate the roadway barrier separating the transit station from a nearby area such as an employment center, university, retail area, civic area, residential neighborhood, or other attraction. 15) Vehicle facilities must not dominate the pedestrian facilities. 16) Open surface parking lots are strongly discouraged. Head-in or parallel parking along internal driveways is acceptable. 17) Ground floor level garage parking within a multistory building must be behind storefronts or ground floor level residential units, and not directly adjacent to the sidewalk. 18) Bicycle parking facilities are required. e) Building design guidelines: Transit oriented residential development shall include the following requirements: 1) Residential development shall be designed as part of an area that includes a mix of commercial uses, accessible through a pedestrian oriented environment achieved by orienting buildings to the street frontage, access to public spaces, and include street trees and lighting to provide a safe, comfortable environment. 2) Residential occupancies may be allowed on the first floor of a building if retail, office, or other nonresidential uses are existing or proposed on the immediately adjacent property, or across the street. 3) All buildings shall comply with the following building design and material guidelines: a. Building massing and height: Restrictions on minimum building height are intended to assure a minimum level of urbanity and building intensity within a transit oriented development. Buildings should be designed to allow relatively simple modifications to accommodate changing uses and occupancies over time without having to be demolished or rebuilt. The following restrictions shall apply: 1. Minimum building height (predominantly residential buildings): Forty-five (45) feet above finished sidewalk grade to mid-line of roof structure or top of parapet (pertains to seventy (70) percent of each property). 2. Minimum building height (predominantly non-residential buildings): Five (5) stories, or sixty-five (65) feet above finished sidewalk grade to mid-line of roof structure or top of parapet (pertains to seventy (70) percent of each property). 3. Minimum building height (civic/public/cultural buildings, exclusive of transit uses): Thirty-five (35) feet above finished sidewalk grade to mid-line of roof structure or top of parapet (pertains to seventy (70) percent of each property). 4. Parking garage massing: Parking garages are excluded from minimum height restrictions but are encouraged to be enclosed by the development they serve, out of public view. 5. Building corner treatments: Buildings shall reinforce a strong corner condition at street intersections. Angled corner clips (or other building conditions which do not form a protruding corner) are not permitted at street intersections, but may occur up to twice within the same block (between street intersections). Buildings shall be designed in accordance with City of Irving required traffic visibility triangles without compromising the corner design. 6. Maximum building length: Buildings shall not exceed four hundred (400) feet in length unless separated by a building break twenty-four (24) feet minimum in length with any connector being a minimum of twenty-four (24) feet behind the front façade. 7. Building articulation: Building façades are encouraged to have massing changes and architectural articulation that provide visual interest and texture along the street corridor. This articulation should not be applied evenly across the building façade, but rather gathered together to create a hierarchical design impact. There shall not be more than forty-five (45) linear feet of unarticulated, blank wall facing any street or public improvement. 8. Minimum residential windowsill height: The sill of windows within ground floor residential units are encouraged to be a minimum of fifty-four (54) inches above finished sidewalk grade. Bedroom windows are also encouraged to meet this exterior sill height as long as building code requirements are met. b. Material and color requirements: The material and color requirements described herein are intended to provide a uniform character and complimentary material relationship between buildings and promote the perception of strength and permanence of each building, while maintaining appropriate variety for design flexibility. 1. Primary cladding materials: The primary cladding material on exterior façades (excluding private courtyards) shall be masonry including brick, finished concrete, stone (natural and manmade), and cementitious stucco. Concrete masonry unit products are permitted within the first two (2) floors only, but must have an architectural finish surface such as split-faced, rusticated, etc. 2. Dominant primary cladding material: No one (1) primary cladding material may comprise more than eighty (80) percent of a building's façade. Cementitious stucco may not comprise more than fifty (50) percent of a building's façade that faces a public street. 3. Primary cladding material combination: No more than two (2) primary cladding materials (excluding glass windows) may be used on a building façade, with one material being dominant. Additional materials (classified as secondary cladding materials) may be used on a special architectural feature such as a tower, corner element, primary entrance articulation, etc., with a maximum of one (1) special feature per building façade. The following materials are prohibited for use as secondary cladding: i. Architectural foam detailing. ii. EIFS. iii. Natural or simulated wood siding (concrete "hardy board" or its equivalent may be used on the fourth floor and above). iv. Exposed aluminum siding. v. Plastic and vinyl siding. vi. Wood roof shingles. 4. Windows and glass: Glass may not comprise more than sixty (60) percent of a building façade. Reflective, mirrored, and spandrel glass are not permitted. 5. Total allowable exterior material combination: No more than five (5) exterior building materials (excluding roof material, but including primary and secondary cladding, and glass) may be used on any building. 6. Material transition around corners: The dominant primary cladding material shall extend around the corner to a building massing break located not less than ten (10) feet from the building corner and then extending back a minimum of two (2) feet from the terminating face. 7. Accent features: The following accent features add detail and are encouraged in the design of building façades: i. Overhangs/eaves. ii. Pilasters. iii. Cornices. iv. String courses. v. Window sills. vi. Lintels. vii. Rustication. 8. Attachments: Railings and walls attached to buildings shall complement primary building design, materials, and colors. 9. Accent colors: Accent colors shall be selected to complement the dominant building color, and may be applied to window mullions, cornices, and other architectural elements. c. Building programming: The following building programming requirements have been designed to create buildings that are pedestrian-oriented, take advantage of mixed-use opportunities, and engage their streetscape environment. 1. Sidewalk entries: Sidewalk entries to buildings shall occur at a maximum of every three (3) ground level units or seventy-five (75) feet for retail/commercial frontages. ADA requirements shall be met by internal ramping. 2. Sidewalk entry hierarchy: Entrances into residential buildings are encouraged to follow a hierarchy of sizes and functions as follows: i. Carriage way — A centrally located twelve-foot wide entrance at sidewalk level for visual and direct access to a private courtyard. ii. Secondary entry — A six-foot wide entrance with ornamental entrance gate and defined by a stoop with low cheek walls and planters at the sidewalk. Mailboxes, bike racks, and trash receptacles should be grouped around these secondary entries. iii. Other entries — Home office and retail storefront entries which are either at grade or stooped shall be sized to accommodate specific requirements of the individual space. 3. Balconies: Balconies may be used in all types of development. Painted architectural metal railings are encouraged. 4. Retail/commercial requirement: All residential developments are encouraged to provide ground floor area for retail/commercial uses. Although these spaces may currently be used for residential units/office use, they should be designed for easy conversion to retail/commercial uses and furthermore be constructed to commercial standards. Where provided, ground floor area for nonresidential uses shall be constructed to nonresidential construction standards to a depth of a minimum of thirty (30) feet. Leasing offices, fitness centers, and related accessory uses in residential developments may count toward meeting this requirement. The retail/commercial feature may be excluded if retail/commercial uses exist or are being developed either across the street from the residential building or on the property immediately adjacent to the residential building. d. Exterior illumination: Exterior illumination discourages "dead spaces" within an urban environment. Because transit oriented development is pedestrian-oriented, illumination of buildings is encouraged to promote the safety and visual experience of all pedestrians while providing an architectural opportunity to highlight the transit oriented development area as inherently unique. Accent illumination is encouraged across all exterior building walls and for all walkways. e. Parking areas: The purpose of parking area requirements is to ensure that the parking areas themselves are not the dominant feature of the transit oriented development. These requirements severely restrict on-site surface parking (other than incidental parking in association with residential development leasing offices, or head-in or parallel spaces to support retail uses) and encourage physical consistency throughout the transit oriented development, including the appearance of parking garages. 1. Allowable parking: Parking areas shall be limited to structure or below grade with the exception of on-street parking and minimal surface parking areas to support retail uses or stand alone restaurants. On-street parking shall not be designated per individual business or occupancy but may count toward the minimum parking requirements for the entire structure along the adjacent frontage. Parallel parking, head-in parking along streets, and/or minimal surface parking is permitted subject to approval through the site plan or development plan process. 2. Parking supply: Parking areas shall be sufficient to meet all parking needs for employees, company vehicles, customers, and visitors. Nonresidential uses within one thousand (1,000) feet of the transit station may have the parking requirements reduced by twenty (20) percent from the city's standard requirements. Nonresidential uses between one thousand (1,000) feet and two thousand (2,000) feet of the transit station may have the parking requirements reduced by ten (10) percent from the city's standard requirements. These reductions do not apply toward the minimum handicapped-accessible parking requirements. 3. Shared parking: Shared parking is allowed as approved by the city to reduce the overall parking demand in the entire district and to capitalize on off-peak parking opportunities. 4. Improved pedestrian access shall be provided between structured parking facilities and public streets. 5. Bicycle parking facilities shall be located within fifty (50) feet of the entrance to the building they are intended to serve, shall be securely anchored, and shall hold bicycles securely with adequate support to prevent bicycles from falling over. 6. Façade requirements: The following requirements shall apply to parking garages: i. The narrow façade of the garage is encouraged to be the exposed side. ii. The exposed façade(s) of the parking garage shall have an architecturally finished surface that is compatible with surrounding development. iii. Street-fronting openings in parking structures shall not exceed fifty-five (55) percent of the façade area. They shall be similar in appearance to adjacent development and placed in a manner that effectively screens all parked vehicles. f. Driveways: Like parking garages, driveways are not intended to dominate the streetscape of a transit oriented development. These requirements are intended to promote pedestrian-oriented design that minimizes conflict with vehicular uses. Curb cuts shall be limited to no more than one (1) per two hundred (200) feet of development street frontage. Requests for additional curb cuts beyond this amount will be reviewed and determined based on demonstrated need and safety considerations. g. Material and delivery loading areas: Material and delivery service areas, while necessary, are to be screened as completely as possible from the adjacent streets. Placement: The placement of loading or service areas shall be subject to approval as part of the site plan or development plan. h. Signage: The purpose of signage is to ensure that tenants, residents, and visitors can quickly and easily make their way to, through, and from the transit oriented development. Signage should be designed appropriately to contribute to the overall identity and way-finding system. At a minimum, all signage is to meet the requirements of the city sign ordinance with the following two (2) exceptions: 1. Special event banners: Banners may be mounted to a vertical support, attached to a building or parking deck, or across the street. Banners which are mounted to a vertical support may be integrated onto street and pedestrian light poles. Banners may display artwork or a message that pertains to the district or a special event. 2. A-frame or "sandwich" signs: The sign shall be sufficiently weighted or anchored. A-frame signs may be placed within the public right-of-way during business hours, but must be removed whenever the business is closed. i. Fencing: To promote the street-oriented, pedestrian-friendly atmosphere of the transit oriented development, fencing needs to be regulated so as not to create barriers which interfere with the desired pedestrian street and promenade experience. 1. Fencing scope: Fencing shall not screen the entire development. Non-permanent fencing (e.g., around outdoor dining/seating areas) may encroach into the front building setback. 2. Maximum length: Except for pool safety fencing, the maximum length for a fence section shall be fifty (50) feet with a minimum twenty-foot break between sections. 3. Materials: All fencing shall be wrought iron or steel, of compatible design with the adjacent architecture. Chain link fencing is not an allowed material. 4. Maximum height: Fencing height shall not exceed current city standards. 5. Exceptions: In areas where guardrails are required by code, they shall meet those requirements while maintaining a compatible appearance to adjacent architectural and fencing components of the development. j. Screening: The purpose for screening is to mitigate visual impact into areas which exist entirely for functional purposes and not intended to be used or seen by the public. These standards are intended to ensure that these areas do not detract from the visual quality of the surrounding environment. 1. Mandatory screened elements: The following items shall be screened: i. Off-street loading spaces. ii. Service areas. iii. Garbage storage/material recycling areas. iv. Roof mechanical equipment, antennae, satellite receivers, etc. (from the public right-of-way and neighboring properties). 2. Garbage collection and material recycling areas: Garbage collection and material recycling areas must be incorporated into the building envelope or screened by a masonry wall at least six-feet in height, or one (1) foot higher than the tallest container it screens, whichever is higher, and shall be accessed through a decorative metal gate that screens the opening. It is encouraged that a continuous dense base planting of indigenous evergreen material that is a minimum of three (3) feet in height at the time of installation be placed in front of all screening walls to soften the vertical impact of the wall. 3. On-site loading/service areas: Other on-site loading and service areas shall be screened by masonry walls at least six (6) feet in height as described above, or by a continuous dense indigenous evergreen planting that is a minimum of six (6) feet in height at the time of installation. 4. Complementary design: All screening shall be complementary in appearance to adjacent building landscaping design approaches. k. Streetscape and site landscaping: A transit oriented development streetscape is highly urban in character with a density of pedestrian traffic. Therefore, plantings of shade trees, ornamental trees, shrubs, evergreen groundcovers, vines, and seasonal color set in paved surfaces are appropriate for front yard development. Plantings will promote entrance demarcation and pedestrian interest. Flexibility in design will be allowed as long as the intent of these guidelines is not violated. All developments within the transit oriented development district must comply with the landscaping requirements listed below and in so doing, are exempt from all other city landscape requirements currently in effect. 1. Responsibility: Property owners are responsible for providing landscaping and streetscape materials along all public and private streets (including on-street parallel parking islands), in addition to other on-site areas. 2. Front yards: Building entry zones and other special public or semi-public spaces are urban in character with a higher density of pedestrian traffic. Plantings of evergreen groundcovers and shrubs that provide vertical contrast to the sidewalk plane are preferred over grass or sod. In cases where home/office or retail is located on the ground level, a higher intensity of paving is allowable and plantings may be placed in pots or containers. 3. Public access easement: In order to allow continuous public flow across sidewalks throughout the transit oriented development, a series of public access easements shall be maintained along an area within twelve (12) feet from the back of curb of all streets. Non-fixed outdoor dining areas including tables, chairs, umbrellas, A-frame signs, etc., may encroach into these easements as long as a minimum six (6) foot wide continuous unobstructed pathway is maintained. 4. Street trees: Street trees shall conform to the following standards and be spaced between twenty-five (25) feet and thirty-five (35) feet on-center. Private streets are exempted from the below requirements but are strongly encouraged to provide similar treatment along their entire length. i. Major streets. (a) Primary street trees — Drake Elm, Live Oak, Shumard Red Oak, Lacebark Elm (b) Accent street trees — Cedar Elm, Little Gem Magnolia, Texas Ash (c) Preferred hedge — Foster Holly ii. Minor streets. (a) Primary street trees — Live Oak, Lacebark Elm, Shumard Red Oak (b) Accent street trees — Cedar Elm, Little Gem Magnolia, Texas Ash (c) Preferred hedge - Foster Holly l. Paving: Paving is intended to highlight or accentuate special areas along the ground plane while at the same time complementing the design of adjacent building and streetscape elements. 1. Crosswalks: All crosswalks shall be pavers or stamped concrete. Pavers shall be installed over a concrete sub-base, and meet the minimum design rating for heavy vehicular traffic loads. All crosswalk paving must be approved by the public works department. Property owners are responsible for the cost of crosswalks across private streets only. 2. Sidewalk paving: Sidewalk paving along the transit oriented development primary streets and secondary streets shall include accents areas of pavers or stamped concrete comprising a minimum of thirty (30) percent of the paved walkway surface. All sidewalk paving must be installed over a subgrade approved by the public works department and shall be maintained by the adjacent property owner. m. Utilities: Transformers, switchgear, and related utility service equipment shall not be located above ground in the pedestrian access easements referenced in subsection 2.6.5(e)(3)(k)(3) above. Building service panels are to be located on the inside of all buildings. n. Noise attenuation: Buildings located near a commuter rail line station are encouraged to include noise attenuation construction techniques. 4) Transit oriented residential units of any type shall not be restricted as to their numbers of individual units by the zoning ordinance, any zoning district, other overlay district, or other city ordinance. f) Area requirements: Area requirements such as, but not limited to, minimum lot dimensions, density, building setbacks, height, lot coverage, and building separation and landscaping shall be determined on an individual basis as part of the approval of either a site plan zoning case or in the case of property with planned unit development (PUD) zoning, a development plan. g) Open space: A transit oriented development must include improved open space for pedestrian comfort, residents' recreational needs, and to serve as a destination point within the development. Provisions for such open space must be provided as part of any site plan or development plan application proposing either residential or nonresidential development or both. Methods for providing open space may include, but are not limited to, providing it on the applicant's property or on an adjacent tract (with the owners' consent), or the applicant may provide financial support to another property owner within one-half mile of the transit station for the open space to be developed on the other property, or payment into an open space fund maintained by the city for open space construction and/or maintenance within the transit oriented development or the surrounding area, or any other manner acceptable to the city council. In any event, the application for transit oriented development district zoning must include specific provisions for how much open space is being provided, where it is being provided, and what improvements within the open space are being provided. h) Rail line right-of-way dedication: In recognition of the fact that the densities and other provisions for transit oriented development are a direct result and a direct benefit of the construction of a rail line through or near the property proposed for such development, the owner of any property requesting approval of a transit oriented development shall be required to dedicate all required right-of-way for the rail line through the applicant's property unless the required right-of-way has already been dedicated. Without such dedication, the densities and other allowances permitted by the above guidelines will not be authorized by the city. This is in addition to all other street, alley, and/or easement dedications required by the subdivision ordinance. i) Approval process: Any property owner wishing to develop under the transit oriented development district shall submit an application for a zoning change to the transit oriented development district or, in the case of property zoned planned unit development (PUD), approval of a development plan for transit oriented development district uses. 1) Along with the zoning change application or development plan application, the applicant must also submit a transit oriented development plan which shall show the proposed development in context with the transit station and the connectivity to other property both within and beyond the proposed transit oriented development. The plan shall indicate the proposed uses, area requirements, building elevations and materials, open space, pedestrian facilities, landscaping, etc. A narrative and other appropriate exhibits shall be provided which explain how all the criteria for designation as a transit oriented development listed in subsection (d) above have been addressed. 2) The transit oriented development plan required by subsection (i)(1) above for development of a parcel of less than five (5) acres shall include all the elements required for approval of a detailed site plan (S-P-1) zoning case as described in section 2.7.3(b) of this ordinance, plus elevation drawings of all proposed buildings and detailed information regarding provisions for open space. If any portion of the property included within a transit oriented development plan of less than five (5) acres includes multifamily uses, the transit oriented development plan shall also include the total number of dwelling units, the number of one (1), two (2) and/or other bedroom units and the resulting amount of parking required and provided, the density in units per acre, and the total gross floor area for each type of use. The transit oriented development plan shall also include a proposed utility layout showing proposed easements, the placement of transformers, switchgears, pedestals, light poles and other utility infrastructure and how these relate to the pedestrian environment and the streetscape. The transit oriented development site plan required by section (i)(1) above for development of a parcel of five (5) acres or more may include all the elements required for approval of a detailed site plan (S-P-1) zoning case as described in section 2.7.3(b) of this ordinance, plus elevation drawings of all proposed buildings and detailed information regarding provisions for open space, or, as a minimum, all the elements required for approval of a generalized site plan (S-P-2) zoning case as described in section 2.7.4(b) of this ordinance, plus a concept plan of the proposed development and detailed information regarding provisions for open space. However, prior to issuance of a building permit, each proposed building within an originally approved area of five (5) acres or more without a detailed transit oriented development plan as required for a parcel of less than five (5) acres must first be approved by the planning and zoning commission and city council through the submittal of another transit oriented development plan which includes all the elements required for approval of a parcel of less than five (5) acres as described above. Since the zoning of transit oriented development district is already in place on the subject property, there shall be no requirement for notification of adjacent property owners for such transit oriented development plan. 3) In order to ensure the complete coordination of each proposed development and the full provision of services, the following issues shall be addressed and submitted to the public works department for approval as part of the transit oriented development plan: (a) proposed banners and/or features intended to support banners in or over the right-of-way; (b) street lighting and illumination, purchase of fixtures and long-term maintenance of fixtures; (c) sight distance data at all street and driveway intersections; (d) design standards for sidewalk and street paving accent areas and long-term maintenance of them; and (e) coordination of immediate and future utilities. The specific intent of this additional requirement is to anticipate and resolve any conflicting requirements and to ensure the ongoing health and safety of the public. 4) As part of the building permit review and issuance process, the director of planning and development or his/her designee may approve minor variations to an approved transit oriented development plan, provided that such variations do not: (a) change the character or configuration of the development; (b) change the intent of the planning and zoning commission and city council; (c) alter the basic relationship of the development to adjacent property; (d) change the uses permitted; or (e) grant any additional variances or exceptions to this or any other city ordinance not previously approved by the city council. The director of planning and development or his/her designee shall not be required to approve a request for a minor variation, but may choose to deny a request that he/she determines to be other than a minor variation. If an applicant disagrees with the determination of the director of planning and development regarding a minor variation, the applicant may appeal the decision to the planning and zoning commission and city council by submitting a revised transit oriented development plan. The revised transit oriented development plan shall first be presented to the planning and zoning commission for a recommendation, and then forwarded to the city council for a final determination. Since the zoning of transit oriented development district is already in place, there shall be no requirement for notification of adjacent property owners for a revised transit oriented development plan. 5) Multifamily developments that comply with the guidelines of the transit oriented development district shall be considered to have satisfied the requirements for a community framework plan as required in section 3.13.1 Multifamily Development Regulations. 2.6.6 Heritage Crossing District (HCD). a) Introduction. This section provides the regulatory tools for new development and redevelopment consistent with the community vision for the Heritage Crossing area. 1) Purpose and intent. The purpose of the Heritage Crossing District is to implement the vision previously outlined in the adopted Downtown Development and Heritage Crossing Redevelopment districts. It facilitates pedestrian oriented, mixed-use, urban infill redevelopment, providing shopping, employment, housing, and business and personal services. The Heritage Crossing District supports economic development, a sustainable tax base, and job creation/retention by: a. Providing a streamlined and simplified city approval process; b. Establishing adjacency predictability in the built environment; c. Offering flexibility to changing market conditions; d. Reducing risk to private investment/development; e. Synchronizing private investment/development with public capital investment policies; and f. Calibrating zoning regulations with a vision for redevelopment within the Heritage Crossing District. 2) Goals. The goals of the Heritage Crossing District are to a. Promote a more functional and attractive community through the use of recognized urban design principles; and b. Allow property owners flexibility in land use, while prescribing a higher level of detail in building design and form. 3) Relationship the Irving Comprehensive Plan. The Heritage Crossing District seeks to implement the recommendations of the 2016 Irving Comprehensive Plan relative to Heritage Crossing, including: "Continue to enhance Irving's existing signature centers including: Heritage District." The Heritage Crossing District specifically implements the following recommendations: a. Make downtown more visible to visitors and residents through entranceways, wayfinding signage and public art; b. Capitalize on the location of the TRE station; c. Create pedestrian connections throughout the Heritage District; d. Ensure development throughout the Heritage District is compatible with existing design and supports the neighborhood as a whole; e. Design retail space as a focal point of activity, offering interesting shops, quality restaurants, and essential services in attractive buildings and settings; f. Ensure new office developments fit into the style and character already established by the community and neighborhood; and g. Develop well-designed multifamily projects and outdoor spaces that contribute to a visually pleasing environment that supports Irving's local character and promotes social interaction and pride among its residents. b) Components of this section. 1) The Regulating Plan. The Heritage Crossing District regulating plan ("Regulating Plan") (Attachment 1 included with this section) is hereby adopted as the official zoning map for the Plan Area. Within any area subject to the approved Regulating Plan, this Heritage Crossing District becomes the exclusive and mandatory regulation unless modified by SP-1, SP-2 or any other more specific plan. It shall establish the following development standards for all properties within the Plan Area: a. Establishment of character zones. The Plan Area is divided into different "character zones". Each character zone is intended to create a distinct urban form based on the illustrative vision for different sections within the Plan Area. Each character zone shall establish use and building form standards including standards for building height, width, location, functional design, and parking. The Regulating Plan classifies all lots within the Plan Area into one of the following three (3) character zones: 1. Transit Mixed-Use (TMU) - The Transit Mixed-Use Zone creates opportunities for local small scale, in-line retail and restaurant, and medium-scale urban residential (apartments, townhouses, multi-unit homes, live-work) development. This zone takes advantage of the proximity to the Trinity Railway Express by creating shared parking opportunities and focusing on urban residential, without mandating ground floor retail. 2. Corridor Mixed-Use (CMU) - The Corridor Mixed-Use Zone creates a vibrant, mixed-use area that leverages Irving Boulevard/Second Street as "context sensitive streets" supporting multimodal traffic, linking other regional destinations, and promoting economic development. The Corridor Mixed-Use area will serve as the primary neighborhood for commercial activity in the local community. 3. Neighborhood Mixed-Use (NMU) - The Neighborhood Mixed-Use Zone is intended to provide for a range of small scale residential uses (single-family, low-density apartments, live-work, townhomes, multi-unit homes, etc.) in low intensity development at key locations. It also provides for a mix of home occupation, low-impact office and neighborhood services within the zone. b. Building frontage standards. Buildings along Main Street, Irving Boulevard, and 2nd Street within the Corridor Mixed-Use Zone and west of Britain Street shall be designed to balance pedestrian-oriented building design standards while accommodating service, utility, and parking functions. Specific development applications apply within the Corridor Mixed-Use Zone requirements. 2) Development standards. The Heritage Crossing District text portion of this section 2.6.6 enumerates the development standards with text and graphics for character zones, frontage, building form, landscape and building design. c) Administration. 1) Applicability. a. The uses and buildings on all properties within the Heritage Crossing District shall conform exclusively to this section 2.6.6 unless otherwise specifically referenced herein. b. Where in conflict, numerical metrics shall take precedence over graphic metrics. 2) Development review process. a. Administrative modifications to the Heritage Crossing District. The director or the director's designee may approve administrative modifications to standards in this section per the criteria set in Table 1 below. A site plan shall be required for administrative review of proposed modifications. Table 1. Administrative Modifications Table Code Standard | Extent of Administrative Modification Permitted | Criteria a. Building Form and Development Standards 1. Build to zones/setbacks | No more than a 20% change in the maximum or minimum setback applicable or 5 feet whichever is greater. | Changes to the build-to-zones and setbacks may only occur when they are caused by one or more of the following:i. Need to accommodate existing buildings and structures on the lot that meet the overall intent and vision for redevelopment in the Plan Area; orii. Need to accommodate other required modes of transportation (transit, bike, pedestrian), storm water drainage, water quality, or low impact development (LID) elements on the site; oriii. Need to accommodate overhead or underground utilities and/or easements; oriv. Need to preserve existing heritage trees on the property, per subsection h) 1) Heritage Tree Preservation of this Section. This modification is not mandatory for tree preservation, but for the allowance for preservation; orv. Need to provide public amenities along the sidewalk (outdoor dining/seating, larger sidewalk, or other similar public amenities). 2. Required Parking Spaces | Reduction in the number of required parking spaces | Reduction in the number of parking spaces shall be based on one or more of the following:i. A shared parking plan for parking within 300 feet of the subject property; orii. A parking study for the uses proposed on the site; oriii. A combination of the above. b. Other 1. Any other numerical standard in this section | A modification up to 10% (increase or decrease) | i. A modification of a numerical standard is needed to accommodate existing conditions.ii. The proposed development still meets the intent of the section. 2. Phased Developments | Deferment of building frontage standards | i. Phased developments may defer building frontage requirements as long as they meet the build-to-zone and parking setback requirements. 3) Nonconforming uses. Nonconforming uses shall meet the standards in Chapter UDC-7, Nonconformities of this ordinance. 4) Nonconforming structures and sites. For the purposes of this section, a "nonconforming structure or site" means a structure or site that does not meet the current standards addressed in this section. A nonconforming structure or site may be altered or enlarged, provided that such alteration or enlargement neither creates any new nonconformity nor increases the degree of the existing nonconformity of all or any part of such structure or site. 2.6.6(i) provides examples of acceptable additions to nonconforming structures in the Heritage Crossing District. d) Definitions. Many terms used in this section are defined in Chapter UDC-9 of this ordinance. Definitions are only included in this section if not defined in the Irving Land Development Code, or if the definition for this section differs from the Irving Land Development Code. In case of a conflict between the definitions under this section and Chapter UDC-9, the definitions in this section shall supersede. 1) Administrative modification shall mean a requested modification to Heritage Crossing District standards that complies with the administrative modifications provisions of section 2.6.6(c)(2) - Administration. The director shall have the authority to administratively approve a request for an administrative modification in conformance with subsection (c)(2). 2) Arcade shall mean a portion of the main façade of the building that is at or near the property line and a colonnade supports the upper floors of the building. Arcades are intended for buildings with ground floor commercial or retail uses and the arcade may be one or two stories. The ground floor area within the arcade may be conditioned or non-conditioned space. Any habitable arcade space within the public right-of-way shall require legal permission from the city prior to construction. [image] Images of arcade buildings 3) Bed and breakfast shall mean a dwelling occupied as a permanent residence by an owner or renter which serves breakfast and provides or offers sleeping accommodations in not more than eight (8) rooms for transient guests for compensation. 4) Build-to zone (or "BTZ") shall mean the area between the minimum and maximum front setbacks from the property line. The principal building façade line shall be located within this area [image] | Illustration indicating the location of the build-to zone relative to the minimum and maximum setbacks and the building façade line 5) Building form and site development standards shall mean the standards established for each character zone including but not limited to building placement, building height, parking, service access, and other functional design standards. 6) Building façade line shall mean the location of the vertical plane of a building nearest a street frontage. [image] Section View - Gallery Building | Section View - Arcade Building [image] Building Façade Line Illustrations 7) Building frontage shall mean the percentage of a building's façade line that is required to be located within the Build-To Zone as a proportion of the lot's width along the fronting public street. Required driveways, stairs to access entrances, parks, plazas, squares, improved forecourts, and pedestrian breezeway frontages shall count towards the required building frontage. [image] Image showing building frontage calculation 8) Building step-back shall mean the setting back of the building façade line away from the street at a specific floor or height. [image] Illustration of a building step-back 9) Character Zone shall mean an area within the Heritage Crossing District that is intended to preserve and/or create an urban form that is distinct from other areas within the plan area. Character zones are identified in the regulating plan. 10) Commercial use or mixed-use building shall mean a building in which at least the ground floor of the building is built to commercial-ready standards and any of the floors are occupied by non-residential or residential uses. 11) Commercial ready shall mean a ground floor space constructed with appropriate building orientation, entrance and window treatment and floor-to-ceiling height in order to accommodate ground floor retail/commercial uses (including but not limited to commercial, retail, restaurant, entertainment, and lobbies for civic, hotel, or multi-family uses). Standards for commercial-ready frontage are in this section 2.6.6(g)(3). Prior to the issuance of a certificate of occupancy for a retail/commercial use in a commercial-ready space, the space must comply with all building and construction codes for commercial uses. The intent of commercial-ready space is to provide the flexibility of occupying a space in accordance with market demand and allowing the use in such space to change to retail/commercial uses accordingly. 12) Complete street shall mean a street that not only accommodates various modes of transportation such as automobiles, transit, bikes, and pedestrians, but also establishes a design context that is conducive for redevelopment along the street. 13) Director shall be the Planning and Community Development director or the director's designee. 14) Encroachments shall mean any structural or non-structural element such as a sign, awning, canopy, terrace, or balcony that breaks the plane of a vertical or horizontal regulatory limit, extending into a setback, into the public right-of-way, or above a height limit. 15) Façade area shall mean the surface area of a building's elevation (including all floors) not counting minor indentations fronting a particular street. Ground floor façade area is the surface area of a building's ground floor elevation not counting minor indentations fronting a particular street. Upper floor façade area is the surface area of a building's upper floor elevations not counting minor indentations fronting a particular street. 16) Gallery shall mean a roofed promenade or canopy, especially one extending along the wall of a building and supported by arches or columns on the outer side. The gallery space is unenclosed (non-conditioned) space and may be two (2) or more stories tall. Any habitable gallery space within the public right-of-way shall require legal permission from the city prior to construction. [image] Images of Galleries 17) Heritage crossing district shall mean the zoning designation intended to implement the vision outlined in the previous Downtown Development and Heritage Crossing Redevelopment districts. It facilitates pedestrian oriented, mixed-use, urban infill redevelopment, providing shopping, employment, housing, and business and personal services. 18) Heritage crossing regulating plan shall mean the regulating plan shall be reflected on the official zoning map of the city and in Attachment 1 of this section. The regulating plan graphically depicts development standards including character zones, street designations, and special requirement(s) applicable to properties within the Heritage Crossing District. 19) Heritage tree shall mean any Post Oak tree(s), Blackjack Oak tree(s), or any tree(s) that is 24"-caliper or greater. 20) Live-work unit shall mean a dwelling unit that is also used for work purposes, provided that the "work" component is restricted to the uses of professional office, artist's workshop, studio, or other similar uses and is located on the street level. The "live" component may be located on the street level (behind the work component) or any other level of the building. Live-work Unit is distinguished from a home occupation otherwise defined by the Irving Land Development Code, as amended, in that the work use is not required to be incidental to the dwelling unit, non-resident employees may be present on the premises, and customers may be served on site. 21) Multi-unit home shall mean a multi-unit residential building (two (2) to four (4) units) that is designed to appear as a large single-family home from the exterior, but functions as a multi-unit building on the interior. Multi-unit homes have one main front door for the building, but may also have side and rear entries. Parking (as defined in this section) is accessed from an alley or a driveway leading to the rear of the lot. Parking may not face a public right-of-way. [image] Images of multi-unit homes 22) Numerical standard shall mean any standard that has a numerical limit (minimums and maximums) or value as established within both the text and graphic standards of the Heritage Crossing District. 23) Parking setback line shall mean the distance that any surface parking lot is to be set back from either the principal building façade line or property line along any street frontage (depending on the specific standard in the character zone). Surface parking may be located anywhere behind the parking setback line on the property. [image] Illustration of a parking setback line 24) Primary entrance shall mean the main entrance located along the front of a building facing a street or sidewalk that provides access from the public sidewalk to the building. It is different from a secondary entrance which may be located at the side or rear of a building providing private-controlled access into the building from a sidewalk, parking or service area. 25) Public space shall mean publicly-accessible open space in the form of parks, courtyards, forecourts, plazas, greens, playgrounds, squares, etc. 26) Residential use building shall mean a building that is built to accommodate only residential uses on all floors of the building such as a detached single-family home, attached single-family home (i.e. townhome), two-or three-family home (i.e. duplex, triplex), multiple family (four (4) or more), apartment building (under single ownership or under multiple owners within a condominium regime). 27) Service-related uses shall mean parking access, garbage/trash collection, utility meters and equipment, loading/unloading areas, and similar uses which support the principal use on a lot. 28) Street screen shall mean a freestanding wall, living fence, or combination fence built along the frontage line or in line with the building façade along the street. It may mask a parking lot or a loading/service area from view or provide privacy to a side yard and/or strengthen the spatial definition of the public realm. e) Schedule of permitted uses. 1) Applicability. Due to the emphasis on urban form over land uses in the Heritage Crossing District, general use categories have been identified by character zone (Table 2). Table 2. Heritage Crossing District Land Use Table P = Permitted — = ProhibitedP/AC = Permitted with Additional Criteria CUP = Permitted by Conditional Use Permit Only Uses | Character Zones | Additional Criteria Transit Mixed-Use(TMU) | Corridor Mixed-Use(CMU) | Neighborhood Mixed-Use(NMU) a. Residential Uses 1. Duplex | — | P | P 2. Multi-family residential (greater than 8 units) | P/AC | P/AC | — | Ground Floors along Main Street and Irving Boulevard shall be built to Commercial Ready Standards. 3. Multi-unit home (2 to 4 units) | — | P/AC | P/AC | i. Building shall be designed to appear as one home with one front door.ii. Additional doors may be used on the side and rear to meet required access.iii. Parking shall be located in the rear of the lot and shall be accessed from an alley or by a driveway leading to the rear. 4. Multi-unit residential (5 to 8 units) | P/AC | P/AC | — 5. Single-family residential (Detached) | — | P/AC | P | Allowed adjacent to 6th Street or South of 6th Street and South of 2nd Street. 6. Townhouse | P/AC | P | P | Used for transition from existing single-family detached areas. b. Commercial uses 1. Admin and business offices | P | P | P 2. Art gallery | P | P | P 3. Art workshop | P | P | P 4. Bed & breakfast | — | P | P 5. Business or trade school | P | P | — 6. Commercial amusement - Indoor | P | P | — 7. Commercial amusement - Outdoor | P | P | — 8. Commercial off-street parking as a primary use | CUP | CUP | — | New surface parking lots shall be permitted as an interim use of property if they are part of a phased development or providing public parking pending area development. 9. Construction sales and services office (not to include equipment or materials storage yard) | P | P | — 10. Event Center/Rental Hall | P | P | — | CUP required when within 500 feet of an R Single Family District, measured property line to property line and/or the total square footage of the space is greater than 2,000. 11. Farmers' Market | P | P | — | An office or pavilion with permanent public restroom facilities shall be constructed. 12. Financial services/depository | P | P | — 13. Food preparation/catering | P | P | — 14. Funeral services | P/AC | P/AC | P/AC | i. Pick-up and drop-off lanes, storage of vehicles, service areas, and drive through facilities shall NOT have direct frontage along Main Street, Irving Boulevard or 2nd Street.ii. All such areas along other streets shall be screened with a required street screen (see subsection (h)(2) of this section for landscape screening standards). 15. General retail sales | P | P | — 16. Grocery store | P | P | — 17. Hotel/motel | P | P | — 18. Laundromat/dry cleaning | P | P | — 19. Medical offices - greater than 3,000 SF (including wellness clinics) | P | P | — 20. Medical offices — 3,000 SF or less (including wellness clinics) | P | P | P 21. Pawn shop services | P | P | — 22. Printing and publishing | P | P | — 23. Professional office | P | P | P 24. Restaurant | P | P | P 25. Short-term rental | P | P | CUP | Chapter 8, Art. XI, Short-Term Rental Registration of the Irving Code of Civil and Criminal Ordinances 26. Theater/Concert Hall | P | P 27. Vehicle rentals | CUP | CUP | — | i. Drive through lanes, service bays, and/or gas station canopies shall meet the design standards in subsection (g), Building Design Standards of this code.ii. Outdoor storage of vehicles or other products sold shall NOT have direct frontage along pedestrian frontages. Outdoor storage of vehicles and/or other products sold shall be screened with a required street screen along General Streets (see subsection (h)(2) of this section for standards). 28. Vehicle repair services | CUP | CUPP/AC (east of Britain only) 29. Vehicle sales | CUP | CUPP/AC (east of Britain only) 30. Vehicle washing (of any type) | CUP | CUPP/AC (east of Britain only) | — 31. Veterinary services | P | P | — 32. Any use with a drive through window or drive up service (including banks and financial institutions; pharmacy; dry cleaning and pressing shop; funeral homes and mortuaries; retail store; restaurant) | P/AC | P/AC | — | i. Drive through or drive-up facilities shall meet the design standards in subsection (g)(4) of this code. c. Civic uses 1. Assisted living | P | P | — 2. Club or lodge | P | P | P 3. College or University facilities | P | P | P 4. Communication service facilities | P | P | P 5. Counseling services | P | P | P 6. Day care services | P/AC | P/AC | P/AC | Drive through, driveway, stacking, loading and parking plan subject to site plan approval. 7. Governmental uses | P | P | P 8. Hospital services | P | P | — 9. Local utility service | P/AC | P/AC | P/AC | i. Outdoor storage of fleet vehicles, service areas, utility boxes and equipment shall NOT be permitted located along Main Street, Irving Boulevard or 2nd Street.ii. All such areas along other streets shall be screened with a required street screen (at least as high as the equipment being screened) (see subsection (g) of this section for standards). 10. Maintenance & service facilities | P/AC | P/AC (east of Britain only) | — 11. Major utility facilities | P/AC | P/AC (east of Britain only) | — 12. Museum, art gallery and related cultural services | P | P | P 13. Park & recreation services | P | P | P 14. Postal facilities | P | P | P 15. Private education/charter school | P/AC | P/AC | P/AC | Drop off and loading study required in site plan process 16. Public education | P/AC | P/AC | P/AC | Drop off and loading study required in site plan process 17. Community garden | P | P | P 18. Railroad facilities | P | — | — 19. Religious assembly | P | P | P 20. Telecommunication tower | P/AC | P/AC | P/AC | Subject to § 3.9 and located on top of a building or architectural component only 21. Transportation terminal | P | P | — d. Industrial Uses 1. Manufacturing | CUP | CUP | — 2. Warehousing | CUP | CUP | — 3. Outside Storage | CUP | CUP | — 4. Construction sales and services office with equipment or materials storage yard | CUP | CUP | — e. Other Uses 1. Sexually-oriented businesses | — | — | — 2. Non-depository financial institutions | — | — | — f) Building form and site development standards. 1) All parcels within the Heritage Crossing District are assigned to one (1) of three (3) character zones: a. Transit Mixed-Use (TMU) b. Corridor Mixed-Use (CMU) c. Neighborhood Mixed-Use (NMU) 2) In addition to standards that apply to all character zones, building form and site development standards applicable to each character zone are described below in subsections (f)(10), (f)(11), and (f)(12). 3) The images and graphics in the first subsection of each character zone standards are provided for illustrative purposes only. Refer to the standards in the following subsections for the specific building form and site development standards. 4) The graphics used to illustrate the building form and development standards in each character zone are not intended to indicate exact conditions within each character zone. Rather, illustrations are conceptual and standards are to be applied based on the specific frontage types designated along the subject property or site. For example, a specific site may not have frontages along all streets as indicated in the illustrations and only the standards applicable to designated building frontages on the property should be used. In addition, the illustrations may depict other site elements to establish context and only the standards regulated by the specific subsection shall apply. For example, the building placement graphics may depict sidewalks for context purposes only and the graphic should only be used to establish standards for building placement on the site. Building form graphics in this section are NOT TO SCALE . 5) Parking and service access. a. Location of parking (both structured and surface) shall be per the character zone specific building form standards found in subsections (f)(10), (f)(11), and (f)(12). b. Minimum required off-street parking spaces shall be provided per Table 3. Table 3. Parking Ratios Character Zone | TMU | CMU | NMU | Additional Criteria Min. Off-Street Vehicular Parking Requirement All Non-Residential uses and ground floor Commercial-Ready spaces | 1 space per 500 sq.ft. of building area | 1 space per 300 sq.ft. of building area | 1 space per 350 sq.ft. of building area | 1. Off-site parking may be provided per Subsection 4.4.3.2. Landscaping within surface parking lots shall meet standards in the Irving Land Development Code.3. A shared parking plan or alternative parking plan may be approved by the director as an administrative modification.4. On-street parking located along the subject block on any public street adjacent to the property may be counted towards the required off street parking.5. No off-street parking required for retail, restaurant, or office uses on Main Street between Rock Island and Third Street. Multi-Unit Residential (5 to 8 units) and Multi-Family Residential (greater than 8 units) | 1 space per dwelling unit | 1 spaces per dwelling unit | 1.5 spaces per dwelling unit Lodging | 0.5 space per lodging room Single-Family Residential, Townhouse, Multi-Unit Home (2 to 4 units) | 2 space per dwelling unit | 2 space per dwelling unit | 2 spaces per dwelling unit Min. Bicycle Parking Requirement (in Addition to Vehicular Parking) All uses | 1 space required for every 10 provided automobile spaces (Minimum of two) | 1 space required for every 10 provided automobile spaces (Minimum of two) | not required | Location of bicycle parking: For retail and commercial ready buildings, 25% of all provided bicycle parking shall be located within 50 feet of a primary building entrance. Location shall be accessible from a public sidewalk. c. Driveway and service access. 1. Along Main Street, Irving Boulevard and 2nd Street: driveway spacing shall be limited to one (1) driveway per each block face or per two hundred (200) feet of block face for blocks greater than four hundred (400) feet in length, including any existing alleys. 2. Shared driveways, joint use easements or joint access easements shall be required for adjoining properties when driveway and service access is off of Main Street, Irving Boulevard or 2nd Street. 3. Service and loading/unloading areas shall be screened per standards in subsection (g)(4). 4. Front-loaded garages on residential lots less than forty (40) feet wide shall not be allowed. Townhomes shall utilize garages with access from alleys. 5. The director may administratively grant exceptions to the provisions of this section in cases where the director determines meeting the provisions of this section are impractical or represent an unreasonable hardship. 6) Street screen requirements. Any lot frontage along Main Street, Irving Boulevard and 2nd Street with surface parking shall be defined by a Street Screen. This required Street Screen shall be located at the street edge of the Build-to Zone. Refer to the subsection (h) landscape standards in this section for other specifications. 7) Measuring heights. a. Chimneys, vents, elevators, stair enclosures, cupolas, domes, steeples, screened HVAC equipment, other mechanical enclosures, tanks, solar energy systems, and similar elements are exempt from the height limit. Mechanical and utility equipment shall be set back from the façade line in order to minimize visibility from the street. b. Internal building height shall be measured from finished floor to the bottom of the structural members of the ceiling. c. Floor-to-floor heights shall not apply to parking structures, government, educational, or religious buildings. 8) Encroachments and overhangs. a. Encroachments into public right-of-way by canopies, awnings, temporary barriers or patio dining shall require legal permission of the city and shall meet the following criteria. 1. Maximum of fifty (50) percent of the depth of the sidewalk or ten (10) feet (whichever is less). 2. Minimum vertical clearance from the finished sidewalk shall be eight (8) feet. 3. In no case shall an encroachment be located over an on-street parking or travel lane. 4. Outdoor dining may also be placed on the sidewalk as long as ADA required clear space is maintained. b. Overhangs within required setbacks: Canopies, awnings, galleries, and balconies may be within any required setback areas per standards established in each character zone as long as the vertical clearance is a minimum of eight (8) feet from the finished sidewalk elevation. 9) Phased developments. Due to the infill nature of development within the Heritage Crossing District, certain building form and site development standards may be deferred for phased development projects meeting the following criteria: a. Submission of a site plan that illustrates how development and any related private improvements will be phased over time. Each phase of the site plan shall independently comply with all applicable standards of the Heritage Crossing District unless an administrative modification is granted. b. Required private landscaping and open space amenities must also be phased with the building. 10) Corridor Mixed-Use Zone (CMU). a. Illustrations and intent. The Corridor Mixed-Use Zone creates a vibrant, mixed-use area that leverages Irving Boulevard/Second Street as "context sensitive streets" supporting multimodal traffic, linking other regional destinations and promoting economic development. The Corridor Mixed-Use area will serve as the primary neighborhood commercial activity area for the local community. (b) Building Placement [image] | [image] (i) Build-to Zones (BTZ) and Setbacks (Distance from property line to edge of the zone) 1. Front:Along Main Street, Irving Boulevard and 2nd Street | 0 foot min. setback - 25 foot max. setback | A 2. Front:Along all other streets | 0 foot min. setback - 30 foot max. setback 75 foot max setback if parking is in front | B 3. Side | 0 foot min. setback; no max. setback | C 4. Rear | 0 foot min. setback; no max. setback | D (c) Building Height [image] (i) Principal Building Standards 1. Building maximum | ● 3 stories or 45 feet (whichever is less) | A 2. First floor height | ● 12 foot min. for all buildings along Main Street, Irving Boulevard and 2nd Street● 10 foot min. for all other streets | B 3. Upper floor(s) height | ● 9 foot min. | C (ii) Accessory Building Standards 1. Accessory buildings shall meet the standards for principal building standards in the Corridor Mixed-Use Zone. (d) Parking & Service Access (i) Surface Parking Setbacks (with new buildings) [image] 1. Main Street, Irving Blvd. and 2nd Street | ● Shall be located behind the principal building along that street frontage. | A ● 3 feet behind the building façade line along that street. | B ● See subsection (h) for screening requirements. 2. All other streets | ● Shall be located behind the principal building along that street frontage. | C ● If no building is located along the street frontage; then surface parking shall be setback a minimum of 3 feet from the property line. 3. Side | ● 0 foot min. | D 4. Rear/Alley | ● 0 foot min. from property line or alley edge | E 11) Transit Mixed-Use Zone (TMU). a. Illustrations and intent. The Transit Mixed-Use Zone creates opportunities for local small scale, in-line retail and restaurant, and medium scale urban residential (apartments, townhouses, multi-unit homes, live-work) development. It also takes advantage of the proximity to the Trinity Railroad Express Station by creating shared parking opportunities and focusing on urban residential, without mandating ground floor retail. (b) Building Placement [image] | [image] (i) Build-to Zones (BTZs) and Setbacks (Distance from property line to edge of the zone) 1. Front | 5 foot min. setback - 30 foot max. setback 75 foot max setback if parking is in front | A 2. Side | 0 foot min, no max. setback | B 3. Rear | 0 foot min.; no max. setback | C (c) Building Height [image] (i) Principal Building Standards 1. Building maximum | ● 6 stories or 75 feet (whichever is less) | A 2. First floor height | ● 12 foot min. for all buildings facing a public space. | B ● 10 foot min. for all other frontages. 3. Upper floor(s) height | ● 9 foot min. | C (ii) Accessory Building Standards 1. Accessory buildings shall meet the standards for principal building standards in the Transit Mixed-Use Zone. (d) Parking & Service Access (i) Surface Parking Setbacks [image] 1. Street Frontage | ● Shall be located behind the principal building along that street frontage.; or | A ● Min. 3 feet behind the building façade line along that street | B ● See subsection (h) for screening requirements. 2. Side | ● 0 foot min. | C 3. Rear | ● 0 foot min from property line or alley edge | D (ii) Structured Parking or Below Grade Parking Setbacks [image] 1. Primary façade | ● Shall be located behind the principal building along that street frontage; or | E ● Ground floor: min. of 30 feet from the property line ● Upper floors: may be built up to the building façade line 2. Secondary Façade | ● May be built up to the building façade line; or ● If no building is located along the street frontage; then the structured parking shall meet the minimum setback standards along that façade. 3. Side | ● 0 foot min | F 4. Rear | ● 0 foot min at property line or alley edge | G (iii) Partially Below Grade Parking 1. May be built up to the building façade line along all streets 12) Neighborhood Mixed-Use Zone (NMU). a. Illustrations and intent. The Neighborhood Mixed-Use Zone is intended to provide for a range of small scale residential uses (single-family, low-density apartments, live-work, townhomes, multi-unit homes, etc.) in low intensity development at key locations. It also provides for a mix of home occupation, low-impact office and neighborhood services within the zone. (b) Building Placement [image] | [image] (i) Build-to Zones (BTZs) and Setbacks 1. Front | 10 foot min. setback; no max. setback | A 2. Side Adjacent to Single-Family detached residentially zoned lot | 5 foot min. setback; no max. setback | B 3. Rear Adjacent to Single-Family detached residentially zoned lot | 5 foot min. setback; no max. setback | C (c) Building Height [image] (i) Principal Building Standards 1. Building maximum | ● 3 stories or 45 feet (whichever is less) | A 2. First floor height | ● 10 foot min. for all frontages | B 3. Upper floor(s) height | ● 9 foot min. | C (ii) Accessory Building Standards (a) Shall be regulated per city standards for accessory buildings (d) Parking & Service Access (i) Residential Parking Setbacks [image] 1. All Frontages | ● Shall be located behind the principal building along that street frontage; or | A ● Min. 3 feet behind the building façade line along that frontage; 22 foot minimum from the property line | B 2. Side/Rear | ● 5 foot max; no parking permitted on driveway, or | C ● 22 foot min; parking permitted on driveway | D g) Building design standards. 1) Building Orientation and Entrances for Commercial Use, Mixed-use and Multi-family Buildings. a. Buildings shall be oriented towards Main Street, Irving Boulevard and 2nd Street, where the lot has frontage along those streets. If a building has no frontage along these streets, then it shall front a street or civic space. b. Primary entrances to buildings shall be located on the street along which the building is oriented. At intersections, corner buildings may have their primary entrances oriented at an angle to the intersection. All primary entrances shall be oriented to the public sidewalk for ease of pedestrian access. Secondary and service entrances may be located from parking areas or alleys. c. Primary Entrance Design: Primary building entrances along pedestrian frontage shall consist of at least two of following design elements so that the main entrance is architecturally prominent and clearly visible from that street: 1. Architectural details such as arches, friezes, awnings, canopies, arcades, tile work, murals, or moldings; or 2. Integral planters or wing walls that incorporate landscape or seating elements; or 3. Prominent three-dimensional, vertical features such as belfries, chimneys, clock towers, domes, spires, steeples, towers, or turrets; or 4. A repeating pattern of pilasters projecting from the façade wall by a minimum of eight inches or architectural or decorative columns. [image] Figure showing required building orientation and location of primary entrances [image] Examples of Primary Entrance Designs 2) Façade Composition. a. Commercial Use, Mixed-use, and Multi-family Buildings. 1. Façades greater than 60 feet in length along Main Street, Irving Boulevard and 2nd Street (West of Britain) shall meet the following façade articulation standards. i. Include façade modulation such that a portion of the façade steps back or extends forward with a depth of at least 24 inches; and ii. The distance from the inside edge of a building projection to the nearest inside edge of an adjacent projection shall not be less than 20 feet and not greater than 60 feet. [image] Images showing examples of appropriate building articulation 2. Façade Transparency Requirements. i. All façades shall meet the minimum requirement for façade transparency (percentage of doors and windows) as established in Table 4 below. Ground floor windows and doors along Main Street, Irving Boulevard, 2nd Street façades shall have a rated visible transmittance (VT) of 0.6 or higher. Table 4. Required minimum window requirement by use Use and Floor | Requirement Commercial Use or Mixed-use Buildings Ground Floor | 40% (min.) Upper Floor(s) | 20% (min) Residential Use Buildings Ground Floor | 20% (min.) Upper Floor(s) | 15% (min.) [image] Images showing appropriate transparency required along pedestrian frontages b. Single-family Residential Use Buildings. 1. At least one of the following shall be added along single-family residential use building façades to add pedestrian interest along the street: i. Porches; ii. Stoops; iii. Eaves; or iv. Balconies. 2. Windows and doors. All building façades of single-family residential use buildings shall meet the transparency requirements established in Table 4. [image] Residential buildings with porches, fencing, balconies, and stoops to add interest along the street. 3) Commercial-ready Standards for Commercial Use, Mixed-use and Multi-family Use Buildings. a. Ground floors of all buildings within Corridor Mixed-Use Zone along Main Street, Irving Boulevard and 2nd Street shall be built to commercial-ready standards. Such ground floor space shall be constructed to accommodate, at a minimum, commercial uses. In addition, the following standards shall apply: 1. An entrance that opens directly onto the sidewalk according to subsection (g)(1); 2. A height of not less than 12 feet measured from the entry level finished floor to the bottom of the structural members of the ceiling; 3. Minimum leasable width of 20 feet wide; 4. A front façade that meets the window glazing requirements; and 5. Off-street surface parking shall be prohibited between the sidewalk and the building along Main Street, Irving Boulevard and 2nd Street (west of Britain). [image] Illustration showing application of Commercial Ready Frontage Requirements 4) Design of automobile related building and site elements. a. Where permitted under subsection (e), Schedule of permitted uses, drive-through lanes, auto-service bays, and gas station canopies for commercial uses shall not be located with frontage along Main Street, Irving Boulevard and 2nd Street (west of Britain). Drive-through lanes may be permitted along all other streets or alleys. Drive-through lanes, auto-service bays, and gas station canopies shall be hidden behind a three (3) feet high street screen along all streets. b. No more than sixty (60) percent of a lot's frontage along a street may be dedicated to drive through lanes, canopies, service bays, and other auto-related site elements. There shall be no such limitation along alleys. [image] Image illustrating the appropriate design of auto-related site elements along streets other than Main Street, Irving Boulevard and 2nd Street (west of Britain) c. Any automobile-related retail sales or service use of a site or property shall have a primary building entrance along its frontage. d. Drive through access may be from a street only if the lot has no access to any alley frontage. [image] Image illustrating the appropriate design of retail/restaurant drive-throughs (Corner Lot) e. All off-street truck loading and unloading areas shall be screened using a street screen that is at least as tall as service equipment. The street screen shall be made up of (i) a living screen or (iii) a combination living and primary building material screen. 5) Design of parking structures. a. The amount of street frontage devoted to a parking structure shall be minimized by placing the shortest dimension(s) of the parking structure along the street edge(s). b. Where above ground structured parking is located at the perimeter of a building with street frontage, it shall be screened in such a way that cars on all parking levels are appropriately screened from view. Architectural screens shall be used to articulate the façade, hide parked vehicles, and shield lighting. Parking garage ramps shall not be visible from any street. [image] Illustrative Examples of Parking Garage Screening c. Garage parking in a multi-story building shall be behind storefronts or residential units facing any street frontage in order to substantially inhibit and shield views of the garage from adjacent streets. d. Ground floor façade treatment (building materials, windows, and architectural detailing) shall be continued to the second floor of a parking structure along all streets. [image] Images showing required façade treatment of parking garages along streets e. When parking structures are located at street intersections, corner emphasizing elements (such as towers, pedestrian entrances, signage, glazing, etc.) shall be incorporated. f. Parking structures and adjacent sidewalks shall be designed so pedestrians and bicyclists are clearly visible (through sight distance clearance, signage, and other warning signs) to entering and exiting automobiles. [image] Images showing appropriate design of Parking Structures h) Landscape standards. 1) Heritage tree preservation. a. Preservation of existing trees that are twenty-four (24) inch caliper or larger is a high priority and is considered essential in both new development and redevelopment. Developers will be provided a 1.5 to one (1) credit toward the landscaping requirement for new development for preservation of such trees; i.e. keeping one (1) twenty-four (24) inch caliper tree counts towards planting thirty-six (36) inches of new trees. Post Oak and Blackjack Oak trees are considered relic trees worthy of additional protection. Developers will be provided a two (2) to one (1) credit toward the landscaping requirement for new development for preservation of Post Oak and Blackjack Oak trees of at least six (6) inch caliper. b. Prior to development or redevelopment of any property, the developer shall prepare and submit to the city a detailed tree survey of the property indicating the location, size, and species of all existing trees six (6) inch caliper or larger measured twelve (12) inches above grade. The developer shall also provide a site plan showing the proposed development overlaying the tree survey indicating which trees are proposed to be removed and which trees will be preserved, along with a table indicating the number of trees and caliper inches proposed to be removed and proposed to be preserved. c. Where practical and reasonable, existing trees shall be preserved. Where it is not practical or reasonable, a tree may be removed if it is in the footprint of a new building or the driveway or parking area of the new building. Trees outside those areas shall be preserved, and if damaged during construction, or if they die within two (2) years of construction, shall be replaced in addition to the required landscaping on the site, with an equal number of caliper inches at the same location if practical or other locations within the Heritage Crossing area. If a developer attempts to preserve a tree within five (5) feet of the building, driveway or parking area, or within an easement or within five (5) feet of an easement, no credit will be given, but mitigation will not be required if the tree fails to survive. d. An existing tree that is approved for removal shall not be removed from the property until a building permit has been issued, and development of the site is imminent as evidenced by executed construction-related contracts or other documents acceptable to the director. If a protected tree is removed contrary to the provisions of this subsection (h), the owner of the property from which the tree was removed shall make a payment into a special city account to be known as the Heritage Crossing District Tree Fund. The amount of the payment required is calculated by using the formula for appraising the value of a tree, as derived by the most recent edition of the Guide for Establishing Values of Trees and Other Plants published by the Council of Tree and Landscape Appraisers, unless another publication is designated by the Director. If more than one (1) tree is removed, the values of the trees are added when calculating the payment required. The required payment diminishes equally within each inch replaced through the following alternative approach: the owner of the property from which a tree was removed may mitigate the loss of the tree by the planting of an equal number of caliper inches of new trees with a minimum caliper of six (6) inches each at a location approved by the director within the boundaries of the Heritage Crossing District. 2) Screening standards. a. Street screen requirements. Any frontage along Main Street, Irving Boulevard and 2nd Street (west of Britain) with surface parking at the Build-to Zone shall have a street screen that has a minimum height of three (3) feet and a maximum height of four (4) feet. Furthermore, along all streets (except alleys), service areas shall be screened in such a manner that the service area shall not be visible to a person standing on the property line on the far side of the adjoining street. Required street screens shall be of one of the following: 1. The same building material as the principal structure on the lot; or 2. A vegetative screen composed of shrubs planted to be opaque at maturity; or 3. A combination of the two. b. The required street screen shall be located at the minimum setback line along the corresponding frontage. c. Street screens cannot block any required sight triangles along a cross street or driveway. d. Street screens may include breaks to provide pedestrian access from any surface parking or service area to the public sidewalk. [image] Illustration showing required street screen along all frontages without a building within the BTZ e. All roof mounted mechanical equipment (except solar panels) shall be screened from view of a person standing on the property line on the far side of the adjoining street. The screening material used shall be the same as the primary exterior building material used. [image] Illustration showing required screening of roof and ground mounted equipment i) Changes to nonconforming structures. 1) The following illustrations shall provide guidance to property owners on the allowed and prohibited modifications to existing nonconforming structures and sites within the Heritage Crossing District. a. Allowable additions. The following illustrations show potential allowable additions to nonconforming structures and sites. Additions shall meet the build-to-zone standards of the character zone they are located in. [image] [image] [image] [image] b. Non-allowable additions. The following illustrations show potential non-allowable additions to nonconforming structures and sites since the additions do not comply with the build-to zone standards of the character zone. [image] [image] 2.6.7 High Intensity - Mixed-Use District (HI-MU). a) Purpose and intent. 1) It is the purpose of the High Intensity-Mixed-Use District ("HI-MU" or "District") to create an identifiable multi-use area that encourages development containing a concentrated mix of land uses in the same structure or in close proximity. The goal is to create an exciting, engaging, and successful environment that maximizes the value and location of property within the Planned Unit Development (PUD 6) zoning district. 2) The HI-MU District should include major economic generators with a regional or greater market draw such as high-end retail centers, major employers, restaurants, entertainment, hotels, and dense office development. The HI-MU District could also include a broad mix of complementary uses that encourage leisure and tourism activities, such as entertainment offerings, accommodations, high-density residential, civic and public facilities, parks, and open space. 3) The HI-MU District should be developed to the highest standards in a pedestrian-oriented form that creates quality public places with a safe and efficient sidewalk and street system. The standards of the HI-MU District should provide predictable and consistent administrative procedures that encourage high-quality, sustainable development, flexibility for creative design, and regulatory clarity for current and future property owners and businesses. b) Permitted uses. The following uses shall be permitted within the HI-MU District: 1) Amusement, indoor. 2) Arena. 3) Auto rental, if autos are stored within a building or parking garage. 4) Business service. 5) Civic/government uses, including emergency services. 6) Convention center. 7) Food truck park. 8) Gasoline sales and/or electric vehicle charging station. 9) Heliport/air taxi pad. 10) Hotel. 11) Hotel with condominiums. 12) Multifamily rental units/condominiums. 13) Museum and cultural facilities. 14) Office. 15) Personal service such as a hair salon or spa. 16) Professional service. 17) Public and open space. 18) Recreation, indoor (includes but is not limited to athletic training facility, athletic/rec club, and health club). 19) Restaurant and restaurant with the attendant accessory use of the sale of alcoholic beverages for on-premises consumption. 20) Retail. 21) Theater/concert hall. 22) Transportation facilities, including rail, bus, taxi, and rideshare. 23) Parking structures, mass transit depots/stations. 24) Utility structures and facilities. c) Prohibited uses. The following uses shall be prohibited within the HI-MU District: 1) Auto sales and service not fully enclosed within a building. 2) Businesses with drive through lanes. 3) Data center as a principal use. 4) Drilling or mining facilities or operations of any type. 5) Flea market. 6) Outside storage as a primary use. 7) Sexually Oriented Business. 8) Truck, commercial or commercial equipment and vehicle storage as a primary use. 9) Truck, commercial or commercial equipment and vehicle repair. 10) Warehousing. d) Temporary uses. Uses temporary in nature that are not expressly permitted or expressly prohibited within the HI-MU District may be requested and considered by the City Council in accordance with Unified Development Code Section 1.19, with any approval not to extend beyond six months. e) Additional unidentified uses. The City Council may authorize any additional uses that are not expressly permitted or expressly prohibited within the HI-MU District through a Conditional Use Permit in accordance with the process outlined in Section 2.3.5 of the Unified Development Code, regardless of whether such use is identified in the City's Land Use Table. f) Alcohol sales. Alcohol Sales shall be permitted within the HI-MU District consistent with Section 3.3 "Alcoholic Beverages: Sale, Serving, or Storage" of the Irving Unified Development Code. g) Definitions. Arena means an indoor climate-controlled facility designed with at least 15,000 seats for spectators for entertainment or sporting purposes. An Arena may also include accessory uses directly related to the operations of the facility including an outdoor plaza, athletic training or practice facility, retail, restaurant, hotel, food preparation facility, concession, office, museum, park, entertainment use, heliport, or automobile parking facility. h) Development standards. 1) Approval of Development Standards Required as Prerequisite. a. The Irving City Council intends to amend this section to establish additional Development Standards for the entire HI-MU District prior to the submission of any Regulating Plan application. No application for a Regulating Plan will be accepted or considered without prior adoption by the City Council of the Development Standards contemplated by this subsection. b. Development Standards shall be based on the concepts and best practices of form-based development codes and shall be consistent with the Purpose and Intent of the HI-MU District. 2) Adopted Development Standards shall provide regulations for the development of property, buildings, public and private streets and sidewalks, and civic and public spaces; and shall include but are not limited to standards for: a. Connectivity. b. Street widths/sections based on purpose of the street: such as entry/collector, side street, residential. c. Parkways: sidewalks, street trees, street furniture, landscaping. d. Pedestrian zone - fenestration/window transparency. e. Lighting: pedestrian scale, security. f. Building heights. g. Parking amount and calculation, location and frontage, and screening to publicly visible areas. h. Structured parking street frontage. i. Hotel development standards. j. Public plazas, open spaces and amenities. k. Special sign regulations. l. Other lower density/compact residential. m. Massing. i) Administration/process. 1) Regulating plan. a. Application required. Prior to the submission of any subdivision, platting or building permit application required by the City for development of the property, a Regulating Plan, delineating the intended pattern, layout, and overall expectations for the development, shall be submitted to the City for review and shall be approved by the City Council. Due to the infill nature of development within the High Intensity-Mixed-Use District and the need to retain the comprehensive review and consideration of the development, each Regulating Plan must include all previously approved Regulating Plans and must show all other areas within the zoning district that are not part of the Regulating Plan application or a previously approved Regulating Plan as "future development area." b. Fees. A non-refundable filing fee in accordance with the latest Consolidated Fee Schedule adopted by the Irving City Council shall accompany each application for a Regulating Plan. c. Contents. A Regulating Plan shall include: 1. Layout of the street grid showing connections to existing access points and streets, specifically including primary points of ingress and egress on the site. 2. Street sections including right-of-way widths appropriate for the planned intensity of the adjacent block and buildings. 3. Location of buildings, use typology, massing with planned FAR, number of hotel guest rooms, and number of residential units. 4. Location and identification of permitted land uses and estimated square feet for each use. 5. Parking study, including quantity of parking needed and locations of parking to be provided, either surface or within parking structures. 6. Location of civic uses including police substations and fire stations required to serve the area. 7. Location of public spaces and public amenities, including parks, trail system through the development, and the connections to a trail system as applicable. 8. Proposed access to utilities including locations of necessary easements and drainage structures. 9. Connections to the light rail station. 10. Phase lines, if known. 11. The following information as applicable to the servicing of the entire property in the zoning district: i. Public and private roadways including arterials and collectors and connections to adjacent roadways and highways; ii. Alignments for major water and wastewater lines; iii. Alignments for stormwater drainage facilities; and iv. Public spaces or plazas, parks and open space, if known. 12. Other information required or deemed necessary by the City to review and evaluate the application. d. Review. 1. As part of the review of the Regulating Plan, the City shall consider desirability of the proposed uses, streets, lot and building configuration, compliance with the adopted Development Standards, and consistency with the overall Purpose and Intent of the HI-MU District. 2. To assist in the review of the Regulating Plan, the City may require the submission of other documents and studies deemed necessary to evaluate the application which may include but are not limited to: traffic studies demonstrating the adequacy of the proposed street layout, rights-of-way, and connections to existing streets; and utility studies that demonstrate the adequacy of water, sewer, and drainage systems to serve the proposed development.
( Ordinance 2023-10760 , § 11, adopted 6/8/2023 ; Ordinance 2023-10829 , § 10, adopted 12/7/2023 ; Ordinance 2025-11093 adopted 3/20/2025 ; Ordinance 2026-11311 adopted 7/30/2026 )
Ask a question about Irving law
Corpus searches the Irving sections it holds and shows the ones that match, with their citations. Free, no sign-in.