Code of Civil and Criminal Ordinances of the City of Irving, Texas (Irving Code of Civil and Criminal Ordinances, Charter and Land Development Code current through legislation adopted September 24, 2026 (eCode360 publication IR6873, scraped 2026-11-17)) · Irving Code of Civil and Criminal Ordinances § 41-20

Corpus is an independent public-information project, not the official City of Irving website. Stable reference: corpuslaw.us/code/9fac4eca-c11c-4c64-b81f-915c81d97c23

§ 41-20: Installation required.

(a) It is unlawful for any consumer to fail to immediately install, have tested, and maintain in proper working order, at the consumer's expense, an approved backflow prevention assembly required by the director. (b) If the consumer fails, refuses, or is unable to install, have tested, and maintain an approved backflow assembly requested by the director, the director may discontinue water service to the premises until the requirements have been satisfactorily met. Alternatively, the director may have such installation, tests, or maintenance done and add their costs to the consumer's water bill. (c) Installation requirements. To ensure proper operation and accessibility of all approved backflow prevention assemblies, the following shall apply to the installation of these assemblies: (1) Backflow prevention assemblies shall be installed in accordance with AWWA/ANSI C510, AWWA/ANSI C511, and USC Manual of Cross-Connection Control. The assembly installer shall obtain the required plumbing permits, and have the assembly tested according to section 41-21(a) of this article. (2) At those facilities where the director requires a backflow prevention assembly to be installed at the point of delivery of the water supply, such installation of the assembly shall be located within the limits of the property which the assembly is serving, and within a dedicated water easement as indicated in the most recent version of the City of Irving Water and Wastewater Standard Details. (3) All vertical installations of backflow assemblies shall have prior written approval by the director. Specific make, model, and size for installation shall be submitted for approval. (4) Bypass lines are strictly prohibited unless given prior written approval by the director. (5) No backflow prevention assembly shall be removed from use or relocated, nor may one backflow prevention assembly be substituted for another, without prior approval from the director. (6) All backflow prevention assemblies shall be installed in a manner for ease of access or no higher than five feet above grade. If a backflow prevention assembly must be installed higher than five feet above grade, a permanent platform shall be installed around the assembly. Any currently installed backflow prevention assemblies which, in the opinion of the director, are located in inaccessible locations, or where the tester is subject to physical danger, shall be relocated to an approved location. (7) All facilities that require continuous, uninterrupted water service and are required to have a backflow prevention assembly shall make provision for parallel installation of backflow prevention assemblies of the same type so that testing, repair, and maintenance can be performed. (8) The property owner assumes all responsibility for any damages resulting from the installation, operation, and/or maintenance of a backflow prevention assembly. (9) Upon completion of installation, the director shall be notified of the date of installation, manufacturer, model, type, size, serial number, location, and initial test report of the approved backflow prevention assembly. (d) Reduced pressure principle backflow prevention assemblies or RPPA. In the absence of an air gap, reduced pressure principle backflow prevention assemblies shall be utilized at premises where a substance is handled that would be hazardous to health if introduced into the potable water system. (1) All RPPAs shall be protected from freezing and other severe weather conditions with an approved enclosure. (2) No part of an RPPA shall be submerged in water or installed in a location subject to flooding. (3) All RPPAs shall be installed in a horizontal orientation. (4) Enclosures shall be designed for ready access and sized to allow for the minimum clearances. a. Assemblies two inches and smaller shall have at least six inches of clearance on both sides and on top of the assembly, and 12 inches below and behind the assembly. b. Assemblies larger than two inches shall have a minimum of 12 inches on the back side, 24 inches on the test cock side, and the relief valve opening shall be at least 12 inches above the floor or highest possible water level. (5) Any deviation from these requirements must have written approval from the director. (e) Reduced pressure principle detector backflow prevention assemblies or RPDA. Reduced pressure principle detector backflow prevention assemblies may be utilized in all installations requiring a reduced pressure principle backflow prevention assembly and detector metering. (1) All RPDAs shall comply with the protection requirements for the RPPA. (2) The line-size backflow prevention assembly and the bypass backflow prevention assembly shall be tested and maintained. (f) Double check valve backflow prevention assemblies or DCVA. Double check valve backflow prevention assemblies may utilized at premises where a substance is handled that would be objectionable but not hazardous to health if introduced into the potable water system. (1) All DCVAs shall be readily accessible with adequate room for testing and maintenance. DCVAs may be installed below grade, providing all test cocks are fitted with brass pipe plugs. All vaults shall be well-drained, constructed of suitable materials, and sized to allow for the minimum clearances. a. Assemblies two inches and smaller shall have at least six inches of clearance below and on both sides of the assembly and, if located in a vault, the bottom of the assembly shall be not more than 24 inches below grade. b. Assemblies larger than two inches shall have a minimum of 12 inches on the back side, 24 inches on the test cock side, and the relief valve opening shall be at least 12 inches above the floor or highest possible water level. (2) Any deviation from these requirements must have written approval from the director. (g) Double check detector backflow prevention assemblies or DCDA. Double check detector backflow prevention assemblies may be utilized in all installations requiring a double check valve assembly and detector metering. (1) All DCDAs shall comply with the protection requirements for the DCVA. (2) The line-size backflow prevention assembly and the bypass backflow prevention assembly shall be tested and maintained.

( Ordinance 8140 , § 1, adopted 3/20/2003 ; Ordinance 2025-11144 adopted 8/28/2025 )

Ask a question about Irving law

Corpus searches the Irving sections it holds and shows the ones that match, with their citations. Free, no sign-in.