Code of Civil and Criminal Ordinances of the City of Irving, Texas (Irving Code of Civil and Criminal Ordinances, Charter and Land Development Code current through legislation adopted September 24, 2026 (eCode360 publication IR6873, scraped 2026-11-17)) · Irving Code of Civil and Criminal Ordinances § 41-50
Corpus is an independent public-information project, not the official City of Irving website. Stable reference: corpuslaw.us/code/54fd516e-b983-4f41-83a5-e2c1101b57bc
§ 41-50: Responsibilities of liquid waste generator.
(a) Waste disposal. A generator of liquid waste shall have all liquid waste material picked up from his or her premises only by a liquid waste transporter who holds a valid permit from the city and who shall transport it to an approved site for disposal. (b) Hazardous waste. A generator shall not permit or allow hazardous waste to be removed from the generator's premises except by an operator and vehicle permitted by the appropriate state and/or federal agency for removal of hazardous waste. (c) Signature required. A generator or generator representative shall legibly sign the trip ticket provided by the transporter when a load is picked up by the transporter and shall retain a copy of all trip tickets for a period of at least five years. The generator shall retain completed trip tickets on site and available for inspection during normal operating hours. The generator commits an offense if they refuse to sign a trip ticket. If a generator has a city permit, the city may revoke that permit for any violation of this chapter. (d) Grit/sand/oil trap/interceptor. Grit/sand/oil trap/interceptor shall be designed and constructed to intercept and remove petroleum-based oil, grease wastes, and solids from the wastewater generated by facilities that perform washing, cleaning, or servicing of automobiles, trucks, buses, or similar equipment which are newly proposed or constructed with floor drains in areas of operation. (1) Generators shall design, install, operate, and maintain a grit/sand/oil trap/interceptor in accordance with locally adopted plumbing codes and chapter 8, Building Standards Code, and other applicable ordinances. (2) Grit/sand/oil traps/interceptors shall be installed and inspected prior to issuance of a certificate of occupancy. (3) Grit/sand/oil trap/interceptor installation and/or replacement will be reviewed, permitted and inspected by the city. (4) Grit/sand/oil traps/interceptor shall be cleaned every six months or more often, to ensure proper function. A variance to the pumping and cleaning frequency may be granted at the discretion of the director if documentation the city has on file indicates that the current size of the trap/interceptor, or separator exceeds the current generator requirements. (5) Grit/sand/oil traps/interceptor shall be easily accessible for service and maintenance. (6) Abandoned or by-passed grit/sand/oil traps/interceptors shall: a. Be pumped and completely removed; or b. Be pumped, filled with sand, have all piping removed, the structure capped or plugged, and the lid broken as to make it unusable. (e) Grease trap/interceptor. Grease traps/interceptors shall be required for all food manufacturing facilities, food processing facilities, food service facilities, or significant fats, oils, and grease generating facilities. Substantial changes in use of the facility, or existing facilities which will be expanded or renovated to include a food manufacturing facility, food processing facility, food service facility, or significant fats, oils, and grease generating facilities, where such facility did not previously exist, shall be required to design, install, operate and maintain a grease trap/interceptor in accordance with locally adopted plumbing codes, and other applicable ordinances. Grease traps/interceptors shall be installed and inspected prior to issuance of a certificate of occupancy. Grease traps/interceptors shall be sized, installed, and maintained as follows: (1) The installation or provided grease trap/interceptor shall be of the size and type approved by the director. The proposed grease trap/interceptor shall be able to receive peak flow from the food service establishment or industry and meet the requirements as specified by International Plumbing Code, Sections 1003.3.2 through Section 1003.3.7, and International Plumbing Code Table 1003.3.5.1. a. Gravity grease interceptor size shall be measured with a meals per hour method to calculate retention time measured in gallons of capacity; b. Hydromechanical grease interceptor size shall be measured with the manufacturer's recommended sizing formula to calculate flow rates measured in gallons per minute and meet the minimum grease waste capacity as required by the International Plumbing Code. (2) All grease trap/interceptors shall be located on the exterior of the establishment, unless approved by the City of Irving and in compliance with chapter 8, Building Standards Code. Installation and/or replacement will be reviewed, permitted and inspected by the City of Irving. (3) If the director determines that the grease trap/interceptor is insufficient in size or design, the owner/operator shall install a new grease trap/interceptor as required by this section. (4) Proposal to utilize a combined grease trap/interceptor will be reviewed on a case-by-case basis. (5) Applicants shall submit to the city, pending approval, plans from a licensed plumber or engineer showing drawings, flow calculations and other information deemed necessary by the city to meet the intent of this section. (6) Grease trap/interceptor shall be easily accessible for service and maintenance. (7) Abandoned or bypassed grease traps/interceptors shall be: a. Pumped and completely removed; or b. Pumped, filled with sand, have all piping removed, the structure capped or plugged, and the lid broken as to make it unusable. (8) Applicants shall request a variance on the installation requirements if: a. The applicant reasonably demonstrates the installation of a grease trap/interceptor on the exterior of the establishment is infeasible; b. The alternate installation location shall be in compliance with chapter 8, Building Standards Code; and c. The grease trap/interceptor shall be able to receive peak flow with a plan from a licensed plumber or engineer showing drawings, flow calculations and other information deemed necessary by the city to meet the intent of this section. (f) A generator shall: (1) Maintain collection devices in continuous, proper repair and operation including, but not limited to, pumping and cleaning them at a minimum frequency of every 90 days or more frequently when: a. Twenty-five (25) percent or more of the wetted height of the grease trap or grease interceptor, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment oils or greases; b. The discharge exceeds BOD, TSS, FOG, pH, or other pollutant levels established by the Utilities Director; or c. Upon written directions of the director. (2) Request a variance to the pumping and cleaning frequency if: a. A suitable sampling port of size, location and type specified by the director, located downstream of the grease trap, interceptor, or separator demonstrates through monitoring that a reduced frequency can be justified. b. If documentation the city has on file indicates that the current size of the trap/interceptor exceeds the current generator requirements. (3) Install and maintain a suitable sampling port of the size, location, and type specified by the director downstream of the grease trap, interceptor, or separator and before the sanitary sewer, sampling, and measurement of the wastes and flows. Sampling ports shall be readily accessible for inspection at all times. At the discretion of the director, sampling ports may also be required for generators responsible for introducing excess grease into the collection system; (4) Supervise regular and proper cleaning of collection devices; (5) Report spills and accidents involving collection to director by the first city business day following the spill or accident; (6) Clean up all spills and accidents immediately and have material disposed of by a permitted transporter by proper means; and (7) Ensure that wastewater discharge meets all the standards and requirements of this chapter including BOD, TSS, FOG, and pH as established by the director; cover and securely protect from rain, insects and the emission of odors all used kitchen oils and grease containers. (8) The generator shall maintain the structural integrity and operational condition of the collection devices including: a. The walls, floors, and ceilings; b. The manhole and manhole lids; c. Inlet, outlet, crossover, and vent pipes; d. Inflow and outflow tees; e. The cleanouts and cleanout lids; and f. The flow diverters and baffles. (9) The generator shall repair the collection device with failing structural integrity and operational condition or replace the failing collection device with an equivalent collection device as approved by the director. (g) Automated self-cleaning trap. Automated self-cleaning traps are prohibited unless provided written authorization from the director. Generator that has been approved to operate with an automated self-cleaning trap must submit in the form of a sworn document the proper method of disposal of the liquid waste. Generator must supply the city with a signed quarterly report containing each time the liquid waste was removed from the automatic self-cleaning trap and location or container where the liquid waste was disposed. (h) Business closure. In the event that the establishment ceases operation, the establishment is required to clean the grease trap/interceptor before abandoning the property. If the owner of the business fails to clean the grease trap/interceptor, it shall become the responsibility of the property owner to clean the grease trap/interceptor.
( Ordinance 8140 , § 1, adopted 3/20/2003 ; Ordinance 8834 , § 3, adopted 7/19/2007 ; Ordinance 2013-9522 , § 1, adopted 11/7/2013 ; Ordinance 2020-10405 , § 4, adopted 12/10/2020 ; Ordinance 2025-11144 adopted 8/28/2025 )
Ask a question about Irving law
Corpus searches the Irving sections it holds and shows the ones that match, with their citations. Free, no sign-in.