§ 53-3: Adequacy review process.
(a) Analysis required. The developer shall be required to provide public facility capacity studies for water, wastewater, and storm drainage as part of the building permit submittal. The City reserves the right to require additional studies to determine capacity to serve new development. (b) Infrastructure capacity review by public facility type. (1) Water supply, distribution and treatment. a. All proposed developments shall demonstrate the availability of water supply, distribution and treatment capacity to serve the proposed development at the time of platting or building permit, whichever is first. If no plat is necessary, the study shall be provided prior to the building permit application. The study shall document compliance with the City's Water Master Plan and evaluate existing water system available capacity to serve the proposed development as outlined in chapter 41, water and Sewer Systems, article II, Water and Sanitary Sewer Connection Regulations" of the Irving Code of Civil and Criminal Ordinances, and the Water and Wastewater Design Manual. b. Details regarding water projects incorporated into the Impact Fee Capital Improvements Plan (CIP) may be found in chapter 42 of the Irving Code of Civil and Criminal Ordinances. Developers may receive credit toward required impact fees by constructing eligible facility improvements consistent with chapter 395 of the Texas Local Government Code. c. City staff will coordinate with the City's wholesale water provider on available water supply and treatment capacity and cost, if applicable. If water demands for the development trigger the need for additional treated water above the City's contracted maximum supply, availability of the additional water capacity must be confirmed and approved by wholesale water provider prior to issuance of any permit. (2) Wastewater collection and treatment. a. All proposed developments shall demonstrate availability of wastewater collection and treatment capacity at the time of platting or building permit, whichever is first. If no plat is necessary, the study shall be provided prior to building permit application. The study shall document compliance with the City's Wastewater Master Plan and evaluate existing wastewater system available capacity to serve the proposed development as outlined in chapter 41, Water and Sewer Systems, article II, Water and Sanitary Sewer Connection Regulations, of the Irving Code of Civil and Criminal Ordinances, and the Water and Wastewater Design Manual. b. Details regarding wastewater projects incorporated into the Impact Fee Capital Improvements Plan (CIP) may be found in chapter 42, Impact Fees of the Irving Code of Civil and Criminal Ordinances. Developers may receive credit toward required impact fees by constructing eligible facility improvements consistent with chapter 395 of the Texas Local Government Code. c. City staff will coordinate with the City's wholesale wastewater on available wastewater conveyance and treatment capacity and cost, if applicable. If the hydraulic modeling indicates that the development will increase the wastewater treatment demand to the point that additional wastewater treatment above the City's contracted maximum from the wholesale wastewater treatment provider, developer will be responsible for costs associated with the additional capacity. (3) Traffic, transportation and pedestrian circulation. a. All proposed developments shall demonstrate that the street and road network can accommodate projected traffic from new development at a minimum Level of Service (LOS) as adopted in the City's Master Thoroughfare Plan and Access Management Manual, as defined in the Highway Capacity Manual. Except as otherwise prohibited by state law or this Code, a TIA may be required, as determined by the Director of Traffic and Transportation. Aside from other land uses, all multifamily and mixed-use developments may be required to provide a TIA as set forth in the City's Access Management Manual and as allowed by law. All TIAs, access management requests, and roadway improvements shall use Level of Service "D" as the minimum acceptable standard for all roadways. Where this threshold is exceeded, mitigation measures must be implemented to restore or maintain LOS "D." b. Right-of-way dedication may be necessary to provide for the roadway width of classified roadway facilities as provided in the cross sections in the adopted Master Thoroughfare Plan, if required by the City for the development. c. Driveways shall be provided on the site as identified in the Access Management Manual. Design criteria for driveways, visibility triangles, driveway spacing, driveway throat distances, turn lane designs, criteria for installation of turn lane design and TIA requirements shall be met. Required street design criteria including sidewalk design, alley design, street lighting, traffic signal requirements and traffic control plan requirements shall comply with the Transportation Engineering Design Manual. (4) Storm drainage runoff. a. All proposed developments shall demonstrate the adequacy of downstream drainage systems to accept the runoff from the proposed conditions. 1. The developer shall be responsible for all aspects of performing the analyses including engineering services and the collection of any data necessary to determine the configuration and capacity of existing systems. 2. The drainage analysis shall demonstrate that there are no adverse impacts to public and private drainage systems or other property and that the proposed development is safe from flooding consistent with the standards set forth in chapter 51 of the Land Development Code. 3. Analysis of adequate capacity shall be performed in accordance with Land Development Code, chapter 51, Stormwater Management and Drainage. b. Should downstream drainage systems be demonstrated not to have adequate capacity for the proposed conditions, the developer shall be responsible to identify, design, and construct mitigation measures which would bring the development into compliance. 1. The developer shall be responsible for all costs for implementing mitigation measures. 2. The primary means of mitigation shall be through on-site improvements such as stormwater detention. 3. Should the developer elect to, off-site mitigation measures such as regional stormwater detention or downstream capacity improvements may be implemented. 4. All mitigation measures, both on-site and off-site, shall be analyzed, designed and constructed in accordance with the Land Development Code, Chapter 51, Stormwater Management and Drainage and design criteria required by the City Engineer.
( Ordinance 2025-11146 adopted 8/28/2025 )
Ask a question about Irving law
Corpus searches the Irving sections it holds and shows the ones that match, with their citations. Free, no sign-in.