For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12-62 — Specific standards

Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 12-62

Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/0cc93ef0-d3db-41da-909a-f40175b78fa4

Sec. 12-62. - Specific standards.

In all areas of special flood hazards where base flood elevation data has been provided as set forth in section 12-7, section 12-37(8), or section 12-63(c), the following provisions are required: (1) Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated at least two (2) feet above the base flood elevation. A Texas registered professional engineer, architect, or land surveyor shall submit a certification to the floodplain administrator that the standard of this section as proposed in section 12-39(a)(1), and the standards of the city's adopted drainage design manual is satisfied. (2) Nonresidential construction. New construction and substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor (including basement) elevated at least two (2) feet above the base flood level (confirmed by an elevation certification submitted by a Texas registered professional engineer, architect, or land surveyor) or, together with attendant utility and sanitary facilities, be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A Texas registered professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this subsection and the standards of the city's adopted drainage design manual. A record of such certification, which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed shall be maintained by the floodplain administrator. (3) Enclosures. New construction and substantial improvements, with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access or storage in an area other than a basement and are subject to flooding shall be designed to automatically equalize hydrostatic flood force on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a Texas registered professional engineer or architect, or meet or exceed the following minimum criteria: a. A minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding shall be provided. b. The bottom of all openings shall be no higher than one (1) foot above grade. c. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (4) Manufactured homes. a. Require that all manufactured homes to be placed within Zone A on a community's FHBM or FIRM shall be installed using methods and practices which minimize flood damage. For the purpose of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. b. Require that all manufactured homes that are placed or substantially improved within Zones A1-30, AH, and AE on the community's FIRM be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated two (2) feet above the base flood elevation; and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement on sites located: 1. Outside of a manufactured home park or subdivision; 2. In a new manufactured home park or subdivision; 3. In an expansion to an existing manufactured home park or subdivision; or 4. In an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as a result of a flood. c. Require that manufactured homes placed or substantially improved on sites in an existing manufactured home park or subdivision within Zones A1-30, AH, and AE on the community's FIRM that are not subject to the provisions of this section be elevated so that either: 1. The lowest floor of the manufactured home is two (2) feet above the base flood elevation or higher, or 2. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than thirty-six (36) inches in height above grade and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. (5) Recreational vehicles. Require that recreational vehicles placed on sites within Zones A1-30, AH, and AE on the community's FIRM either: a. Be on the site for fewer than 180 consecutive days; b. Be fully licensed and ready for highway use. A recreations vehicle is ready for highway use if it is on wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has had no permanently attached additions; or c. Meet the permit requirements of section 12-39 of this chapter, and the elevation and anchoring requirements for "manufactured homes" in this section.

(Code 1963, Ch. 9, art. 6, § 5(B) [Ord. No. 87-20, § I, 4-14-87; Ord. No. 87-73, § II, 10-13-87; Ord. No. 89-62, § 1, 8-8-89]; Ord. No. 08-081, § III, 9-23-08; Ord. No. 11-107, § IV, 11-8-11)

Ask a question about Killeen law

Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.