Sec. 30-166. - Types of backflow prevention required.
(a) Generally. Cross-connections vary widely in degree of potential contamination hazards. Backflow may occur under many different pressure differentials, varying from vacuum to very high pressures. The protection afforded by a backflow prevention assembly depends upon its type, the circumstances in which it is installed, and on its proper installation, maintenance and testing. Only approved assemblies shall be used (as defined in section 30-159 of this article). (b) Minimum specific backflow prevention assembly required. Specific backflow prevention assembly requirements for all affected customers and persons shall comply with this Article, TCEQ regulations as provided in title 30, chapter 290 of the Texas Administrative Code and the city's plumbing code, all as amended. In the event that a conflict exists, the most stringent requirement shall control. Only approved assemblies shall be used. The TCEQ table provided below details the types of premises and uses that are commonly subject to compliance with this article, however, notwithstanding this provision or the table below, the director shall retain final approval authority in each individual case. Table Insert: (Figure: 30 Texas Admin. Code (TAC) §290.47(I)) Assessment of Hazards and Selection of Assemblies The following table lists many common hazards. It is not an all-inclusive list of the hazards which may be found connected to public water systems. Premises Isolation - Description of Premises | Assessment of Hazard | Required Assembly Aircraft and missile plants | Health | RPBA or AG Animal feedlots | Health | RPBA or AG Automotive plants | Health | RPBA or AG Breweries | Health | RPBA or AG Canneries, packing houses and rendering plants | Health | RPBA or AG Commercial car wash facilities | Health | RPBA or AG Commercial laundries | Health | RPBA or AG Cold storage facilities | Health | RPBA or AG Connection to sewer pipe | Health | RPBA or AG Dairies | Health | RPBA or AG Docks and dockside facilities | Health | RPBA or AG Dye works | Health | RPBA or AG Food and beverage processing plants | Health | RPBA or AG Hospitals, morgues, mortuaries, medical clinics, dental clinics, veterinary clinics, autopsy facilities, sanitariums, and medical labs | Health | RPBA or AG Metal manufacturing, cleaning, processing, and fabrication plants | Health | RPBA or AG Microchip fabrication facilities | Health | RPBA or AG Paper and paper products plants | Health | RPBA or AG Petroleum processing or storage facilities | Health | RPBA or AG Photo and film processing labs | Health | RPBA or AG Plants using radioactive material | Health | RPBA or AG Plating or chemical plants | Health | RPBA or AG Pleasure-boat marinas | Health | RPBA or AG Private/Individual/Unmonitored Wells | Health | RPBA or AG Reclaimed water systems | Health | RPBA or AG Restricted, classified or other closed facilities | Health | RPBA or AG Rubber plants | Health | RPBA or AG Sewage lift stations | Health | RPBA or AG Sewage treatment plants | Health | RPBA or AG Slaughter houses | Health | RPBA or AG Steam plants | Health | RPBA or AG Tall buildings or elevation differences where the highest outlet is 80 feet or more above the meter | Nonhealth | DCVA Internal Protection - Description of Cross Connection | Assessment of Hazard | Required Assembly Aspirators | Nonhealth† | AVB Aspirator (medical) | Health | AVB or PVB Autoclaves | Health | RPBA Autopsy and mortuary equipment | Health | AVB or PVB Bedpan washers | Health | AVB or PVB Connection to industrial fluid systems | Health | RPBA Connection to plating tanks | Health | RPBA Connection to salt-water cooling systems | Health | RPBA Connection to sewer pipe | Health | AG Cooling towers with chemical additives | Health | AG Cuspidors | Health | AVB or PVB Degreasing equipment | Nonhealth† | DCVA Domestic space-heating boiler | Nonhealth† | RPBA Dye vats or machines | Health | RPBA Firefighting system (toxic liquid foam concentrates) | Health | RPBA Flexible shower heads | Nonhealth† | AVB or PVB Heating equipment Commercial Domestic | Nonhealth† Nonhealth† | RPBA DCVA Hose bibbs | Nonhealth† | AVB Irrigation systems with chemical additives without chemical additives | Health Nonhealth† | RPBA AVB or PVB Kitchen equipment - Commercial | Nonhealth† | AVB Lab bench equipment | Health or Nonhealth† | AVB or PVB Ornamental fountains | Health | AVB or PVB Swimming pools Private Public | Nonhealth† Nonhealth† | RVB or AG RPBA or AG Sewage pump | Health | AG Sewage ejectors | Health | AG Shampoo basins | Nonhealth† | AVB Specimen tanks | Health | AVB or PVB Steam generators | Nonhealth† | RPBA Steam tables | Nonhealth† | AVB Sterilizers | Health | RPBA Tank vats or other vessels containing toxic substances | Health | RPBA Trap primers | Health | AG Vending machines | Nonhealth† | RPBA or PVB Watering troughs | Health | AG or PVB NOTE: AG = air gap; AVB = atmospheric vacuum breaker; DCVA = double check valve backflow prevention assembly; PVB = pressure vacuum breaker; RPBA = reduced-pressure principle backflow prevention assembly. *AVBs and PVBs may be used to isolate health hazards under certain conditions, that is, backsiphonage situations. Additional area of premises isolation may be required. †Where a greater hazard exists (due to toxicity or other potential health impact) additional area protection with RPBAs is required. Uses not listed in this table may require backflow prevention through air gaps or backflow prevention assemblies depending on the nature of the use, the equipment and the plumbing system. These will be determined on an individual basis by the director. (c) Exceptions. A person may request approval from the director for a proposed deviation from or exception to the requirements of this article. Upon request, the director shall conduct a customer service inspection to determine what (if any) hazards are present and shall document what (if any) backflow protection is required and provide the same to the customer. The director may approve a deviation or exception if the deviation or exception does not conflict with applicable law or increase the risk of an actual or potential contamination hazard from entering into the city water system. (d) Criteria for selection of backflow prevention assemblies. The selection of an appropriate backflow prevention assembly depends upon the degree of hazard involved and will be based on the following criteria: (1) whether the assembly could ever be subject to backpressure due to the customer's internal pumping pressures or elevation differentials; (2) the nature of contaminating material under the most critical circumstances; (3) the extent to which additions may be made to the plumbing system at a later date which would affect the initial selection of the assembly; (4) the frequency with which a water supply could be exposed to a hazardous condition; and, (5) the degree of protection of the water supply required, as provided by this article, the local plumbing code and title 30, chapter 290 of the Texas Administrative Code, as enforced by the director. (e) Highly detrimental hazards. Where an actual or potential contamination hazard is determined to be highly detrimental to the general health of the city water system, the director may require a total containment backflow prevention system to provide for backflow prevention assemblies on each internal branch line. The proper backflow protection assembly shall be maintained on each service connection or separation of internal systems. At the point of delivery, an assembly must be installed on each leg or branch (i.e., industrial and domestic). The type of backflow prevention assembly required on each leg or branch shall be in accordance with the highest degree of actual or potential contamination hazard found on the premises. (f) Mobile connections. Any person connecting any part of a vehicle or other container to the city water system shall utilize an air gap method or permanently install an approved backflow prevention assembly on the vehicle or container and shall have the assembly tested in accordance with this article prior to connecting to the city water system.
(Ord. No. 08-040, § II, 5-27-08)
Ask a question about Killeen law
Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.