For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-169 — Customer service inspections

Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 30-169

Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/98f1635e-1715-4fd0-a7ad-abb866721cfb

Sec. 30-169. - Customer service inspections.

(a) A customer service inspection shall be completed prior to providing continuous water service to all new facilities, for any existing facility when the director has reason to believe that potential cross-connections or other contaminant hazards exists, or after any material improvement, correction, or addition to the private distribution facilities that may affect the system's compliance with this article (Texas Admin. Code § 290.46(j)). (b) Only individuals with the following credentials shall be recognized as qualified to conduct a customer service inspection (in accordance with title 30, chapter 290.46(j) of the Texas Administrative Code): (1) Plumbing Inspectors and Water Supply Protection Specialists that have been licensed by the Texas State Board of Plumbing Examiners; or (2) Customer service inspectors who have completed a TCEQ approved course, passed an examination administered by the TCEQ, and hold current professional certification or endorsement as a customer service inspector. (c) The customer service inspection must certify that: (1) No direct connection between the city water system and a potential source of contamination exists and potential sources of contamination are isolated from the city water system by a properly installed air gap or an appropriate backflow prevention assembly; (2) No cross-connection between the city water system and a private water source exists; (3) No connection exists which would allow water to be returned to the city water system; (4) No pipe or pipe fitting containing more than 8% lead has been used for the installation or repair of plumbing at any connection that provides water for human use; and (5) No solder or flux containing more than 0.2% lead has been used for the installation or repair of plumbing at any connection that provides water for human use. A minimum of one lead test shall be performed for each inspection.

(Ord. No. 08-040, § II, 5-27-08)

Ask a question about Killeen law

Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.