For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30-77 — Installation, cleaning, maintenance, and transporter requirements

Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 30-77

Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/cccebce9-d0b0-4719-a30f-ed2c34b3dcf7

Sec. 30-77. - Installation, cleaning, maintenance, and transporter requirements.

(a) Installations. (1) New facilities. (A) Food service establishments which are newly proposed or constructed, or existing facilities which will be expanded or renovated to include a food service establishment, or to expand an existing food service establishment, shall be required to design, install, operate and maintain a grease trap in accordance with the adopted plumbing codes under chapter 8 of this Code of Ordinances and this article. The grease trap shall have adequate capacity to capture all FOG, TSS, BOD and COD in excess of that found in normal domestic wastewater. The food service establishment shall also be required to install and maintain a control point in accordance with section 30-74 of this article. Grease traps and control points shall be installed and inspected prior to issuance of a certificate of occupancy. (B) Commercial service or manufacturing facilities which are newly proposed or constructed, or existing facilities which will be expanded or renovated that generate motor oil, grease, sand, wash water or other substances that will interfere with the wastewater system shall be required to design, install, operate and maintain a grit trap in accordance with the adopted plumbing codes under chapter 8 of this Code of Ordinances and other applicable ordinances. The facility shall also be required to install and maintain a control point in accordance with this article. Grit traps and control points shall be installed and inspected prior to issuance of a certificate of occupancy. (2) Existing facilities. Existing grease or grit traps must be operated and maintained in accordance with the manufacturer's recommendations and in accordance with this division. Grease or grit traps that either do not have adequate capacity to capture all FOG, TSS, BOD or COD in excess of that found in normal domestic wastewater, or sand or other deleterious substances as designed, or that are non-functional shall be replaced at the user's expense upon notification by the director. The director may require an existing facility to install a control point, in accordance with section 30-74 of this article, at the user's sole expense, to enable the director to monitor discharges. (3) Grease Trap Capacity Sizing Criteria. Notwithstanding any conflict found in the adopted plumbing code under chapter 8 or this Code of Ordinances, grease traps shall be sized in accordance with the following minimum criteria. The director may adjust the final grease trap size as needed to protect the wastewater system. Type of Fixture Trap | Trap Arm Size | Fixture Unit Count 3 compartment sink | 1-1/2", 2" | 3, 4 2 compartment sink | 1-1/2" | 2 Dishwasher | 2" | 4 Garbage grinder | 2" | 4 Wok stove | 2" | 4 Floor drains (2",3",4") | 2", 3", 4" | 2,3,4 Floor sinks* (3", 4") | 3", 4" | 3,4 Mop sinks | 2", 3", 4" | 2,3,4 Hand sink | 1-1/2" | 0 Calculation: Grease Trap Holding Capacity (GTHC) (gallons) = GTFR in gallons/minute multiplied by 12 minutes (Applicable Retention Time), where Grease Trap Flow Rating (GTFR) = Total Fixture Unit Count multiplied by 3 gallons/minute. Example: Fixtures: (1) 3-compartment sink (2"), (1) dishwasher, and (2) 4" floor drains = 16 (Fixture Unit Count) * 3 gallons/minute = 48 gallons per minute (GTFR) * 12 minutes = 576 GTHC All facilities are required to install 2-compartment grease traps with a minimum 12-minute total retention time. All floor drains in food preparation area shall drain through the grease trap. (4) All grease and grit trap waste shall be properly disposed of at a permitted facility in accordance with federal, state, and local regulation. (5) Alternate grease removal devices or technologies. (A) An industrial user may propose the use of an alternate grease removal device (AGRD) or other technologies in lieu of a grease or grit trap in those cases where the user can demonstrate that it is impossible or impractical to install, operate, or maintain a grease or grit trap due to one or more of the following conditions: (i) Archeological or historical circumstances prevent the disturbance of the ground or structure where the grease or grit trap and/or plumbing connecting the building fixtures to the grease or grit trap must be installed; (ii) There is not adequate space or alternate locations for installing and maintaining a grease or grit trap; (iii) There is not adequate slope for gravity flow in the building sewer between plumbing fixtures in the building and the grease or grit trap and/or between the grease or grit trap and the wastewater system; (iv) Other conditions or obstacles, in the opinion of the director, prevent the installation of an adequately sized grease or grit trap and control point as required by this divisions 2, 3, 4 and 5 of this article. (B) Alternate grease removal devices or technologies may include, but are not limited to dissolved air flotation, system baffling, active devices, automated grease removal devices, electronic alarms and shut offs or any combination of devices and procedures that will generate a discharge that complies with divisions 2, 3, 4 and 5 of this article. (C) Proposals for the installation of AGRDs or technologies shall be made in writing to the director and shall contain specifications, calculations or other documentation necessary to demonstrate treatment capabilities sufficient to maintain compliance with divisions 2, 3, 4 and 5 of this article. (D) AGRDs or technologies shall be approved by the director in writing prior to the commencement of the installation. This approval by the director in no way endorses the design, device, or its performance, or relieves the user of the responsibility to comply with the requirements specified in divisions 2, 3, 4 or 5 of this article. (E) Where the user proposes AGRDs or technologies, the director may require data demonstrating that the user is able to comply with the limitations or other requirements outlined divisions 2, 3, 4. or 5 of this article. The user may also be subject to periodic monitoring to demonstrate continued compliance. (F) Installed AGRDs or technologies shall be maintained in efficient operating condition, which shall mean a condition that consistently produces an effluent in compliance with requirements divisions 2, 3, 4 or 5 of this article. Any waste generated by an AGRD shall be properly disposed of in accordance with any applicable local, state or federal regulation. (G) The decision of the director to disapprove the use of AGRDs or technologies shall be final. (b) Cleaning and maintenance. (1) Grease and grit traps shall be maintained in an efficient operating condition at all times. "Efficient operating condition" shall mean a grease or grit trap that fully complies with the provisions of divisions 2, 3, 4 and 5 of this article. (2) Each grease or grit trap pumped shall be fully evacuated unless the grease/grit trap volume is greater than the tank capacity on the vacuum truck in which case the transporter shall arrange for additional transportation capacity so that the trap is fully evacuated within a twenty-four (24) hour period, in accordance with 30 TAC § 312.143. Grease and grit trap cleaning and evacuation shall be completed by a transporter permitted under this article to operate within the city. It is a violation of this article for a user to utilize a non-permitted transporter for cleaning and maintenance. (c) Self-cleaning. (1) Grease trap self-cleaning users must apply for and receive approval from the director annually prior to removing grease from user's own grease trap(s). Applications may be obtained from the director and shall be completed and submitted to the director prior to commencing self cleaning and within thirty (30) days prior to the expiration of a previously approved application. The director may approve an application provided that the application confirms that: (A) The grease trap is no more than fifty (50) gallons in liquid/operating capacity; (B) Proper on-site material disposal methods will be implemented (e.g., absorb liquids into solid form and dispose into trash); (C) Grease trap waste will be placed in a leak proof, sealable container(s) located on the user's premises and in an area for the transporter to pump-out; and (D) Detailed records on these activities will be maintained. (2) Self-cleaners must adhere to all the requirements; procedures and detailed record keeping outlined in their approved application to comply with this division. A maintenance log shall be kept by self cleaning users that indicates, at a minimum, the following information: (A) Date the grease trap was serviced; (B) Name of the person or company servicing the grease trap; (C) Waste disposal method used; (D) Gallons of grease removed and disposed of; (E) Waste oil added to grease trap waste; and (F) Signature of the user after each cleaning that certifies that all grease was removed, disposed of in accordance with this division and an approved application, grease trap was thoroughly cleaned, and that all parts were replaced and are in operable condition. (3) Violations incurred by grease trap self-cleaners will be subject to enforcement action including, without limitation, fines and/or removal from the self-cleaner program. (d) Cleaning/inspection schedules. (1) Grease and grit traps shall be cleaned as often as necessary to ensure that sediment and floating materials do not accumulate to impair the efficiency of the grease trap; to ensure the discharge is in compliance with local discharge limits; and to ensure no visible FOG is observed in discharge. (2) Grease traps shall be completely evacuated and inspected a minimum of every ninety (90) days, or more frequently when: (A) Twenty-five (25) percent or more of the wetted height of the grease trap, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, fats, oils or greases; or (B) The discharge exceeds BOD, COD, TSS, FOG, pH, or other pollutant levels established by divisions 2, 3, 4 or 5 of this article; or (C) More frequently if there is a history of non-compliance and the user is administratively directed to do so by the director; or (D) Any time the grease trap is found to have garbage, waste or solids exceeding one-half inch (1/2") in diameter, as necessary to prevent clogs, damage and/or overflows in the wastewater system (3) Any user who owns or operates a grease trap may submit to the director a request in writing for an exception to the ninety (90) day pumping frequency and inspection of their grease trap. The director may grant an extension for required cleaning frequency on a case-by-case basis when: (A) The grease trap user has demonstrated the specific grease trap will produce an effluent, based on standard methods, in consistent compliance with established local discharge limits such as COD, BOD, TSS, and FOG, or other parameters as determined by the director without evacuation every ninety (90) days, or (B) Less than twenty-five (25) percent of the wetted height of the grease trap, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, oils or greases after ninety (90) days. (4) In any event, a grease trap shall be fully evacuated, cleaned, and inspected at least once every one hundred-eighty (180) days. (5) Grit traps shall be completely evacuated and inspected at least once every one hundred-eighty (180) days or more frequently, if required by the director, or if necessary to comply with divisions 2, 3, 4 or 5. (e) Alternative treatment. (1) A user commits an offense if the user introduces, or causes, permits, or suffers the introduction of any surfactant, solvent or emulsifier into a grease or grit trap. Surfactants, solvents, and emulsifiers are materials which allow the FOG to pass from the grease or grit trap into the wastewater system, and include but are not limited to, enzymes, soap, diesel, kerosene, terpene, and other solvents. It is an affirmative defense to an enforcement of this prohibition that the use of surfactants or soaps is incidental to, and not in excess of, normal kitchen hygiene operations. (2) Bioremediation media may be used with the director's prior approval if the user has proved to the satisfaction of the director that laboratory testing which is appropriate for the type of grease or grit trap to be used has verified that: (A) The media is a pure live bacterial product which is not inactivated by the use of domestic or commercial disinfectants and detergents, strong alkalis, acids, and/or water temperatures of one hundred-sixty degrees Fahrenheit (160° F) (seventy-one degrees Celsius, 71° C). (B) The use of the media does not reduce the buoyancy of the grease layer in the grease or grit trap and does not increase the potential for FOG to be discharged into the wastewater system. (C) The use of the bioremediation media does not cause foaming in the wastewater system. (D) The FOG, BOD, COD, and TSS discharged to the wastewater system after use of the media does not exceed the FOG, BOD, COD, and TSS levels which would be discharged if the product were not being used and the grease or grit trap was being properly maintained. pH levels must be between 6 and 10. (3) All testing designed to satisfy the criteria set forth in paragraph (2) above shall be scientifically sound and statistically valid. All tests to determine FOG, TSS, BOD, COD, pH, and other pollutant levels shall be determined in accordance with the standard methods by a state certified laboratory. Testing shall be open to inspection by the director, and shall meet the director's approval. (f) Transporter requirements. (1) Compliance. All transporters providing service to generators using the wastewater system shall at all times comply with all local, state and federal requirements including, without limitation, divisions 2, 3, 4 or 5 of this article and 30 TAC § 312.141 et seq. (2) Notification. All transporters providing service to generators using the wastewater system shall, upon discovering a structural or mechanical failure in a generator's grease, grit or other pretreatment facility that is or may cause a discharge of prohibited waste, wastewater or substances into the wastewater system, immediately notify the generator and the director by telephone and in writing within five (5) days of the discovery of such failure. (3) Transporter permit. Within ninety (90) days from the effective date of the ordinance from which this subsection is derived, all transporters operating within the municipal boundaries of the city must obtain a permit from the city's water and sewer utilities division. Operating as a transporter without a permit issued by the city is a violation of this article. Permits shall be valid for a term of one (1) year from the date of issuance and must be renewed annually. The content of a permit application shall contain, at a minimum, the transporter's TCEQ registration number, the types of liquid waste proposed to be transported, a disposal site identification list, a driver and vehicle identification list, proof of liability insurance for all vehicles utilized to transport liquid waste, and an executed acknowledgement by an authorized representative confirming an understanding and consent to all applicable provision of this article. (4) Permit revocation. If a transporter fails to comply with this article or applicable state law, the city may, upon ten (10) days written notice, revoke a permit issued under this article for a period of one (1) year. Permit revocation under this subsection may be appealed in accordance with division 5 of this article.

(Ord. No. 10-009, § III, 3-30-10; Ord. No. 14-012, 2-25-14)

Ask a question about Killeen law

Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.