For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 31-907 — Site design standards

Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 31-907

Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/ba829f3e-affe-4b89-b5e1-4d343f9d0a5b

Sec. 31-907. - Site design standards.

All new multi-family developments shall meet the following standards: (a) Side and rear elevations visible from a public roadway shall incorporate architectural features consistent with the front façade. (b) Flat roofs, or roofs having a slope less than three (3) over twelve (12), shall require a parapet wall at least thirty-six (36) inches in height. (c) All buildings and structures on a site, including accessory structures, dumpster enclosures, garages, and car ports, must share a common, identifiable, complementary design or style. (d) Dumpsters shall be screened from view on all sides by a concrete or masonry wall, or metal screening fence at least six (6) feet in height. Metal screening fences shall be R-panel or U-panel and shall be coated and capped at the top. (e) Mechanical equipment shall be screened from view on all sides by a parapet wall, screening wall, or continuous landscape hedge. (f) All stairs (except entry stairs and stoops to individual units and shared hallways) and elevated walkways shall be fully integrated into the architectural design of the building.

(Ord. No. 22-027, § I, 4-26-22)

Ask a question about Killeen law

Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.