§ 5-57 — General regulations for firing rooms at shooting galleries
Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 5-57
Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/f893e60d-86f4-4caa-9cf8-834bbbabb5f5
Sec. 5-57. - General regulations for firing rooms at shooting galleries.
(a) The room, place or enclosure wherein the firing of firearms is to take place at a shooting gallery shall comply with all provisions of this section and shall not be used for any other purpose whatsoever during the progress of firing. (b) The rear wall and side walls to a point on a line with the firing position shall be of bulletproof construction in accordance with the following specifications: (1) Not less than six-inch masonry or solid concrete. (2) Wood stud and plaster walls or equivalent construction, faced with one-inch boards backed with one-quarter-inch steel plate. Floors of joist construction shall be considered bulletproof. (3) Ceilings of joist construction shall be faced with one-inch boards up to a maximum distance of fifteen (15) feet from target area in firing direction. (c) All openings of any nature in the rear and side walls shall be protected with one-inch board backed by a one-quarter-inch steel plate. (d) Open steel truss ceilings shall be protected by a one-quarter-inch steel baffle plate inclined toward the firing position. The plate shall be as wide as the total width of the target and not less than five (5) feet in depth, and shall be suspended from the bottom cord of the trusses to a point on a line parallel to the floor and eighteen (18) inches above the intersection of two (2) sight lines drawn from the elevation of the firearm, at the prone firing position to the bottom of the furthest truss, and from the elevation of the firearm at the off-hand firing position to a point five (5) feet above the floor at the target. Baffle plates less than fifteen (15) feet from the firing position shall be protected with one-inch boards. (e) Exposed steel girders less than fifteen (15) feet (horizontal or vertical) from the firing position shall be protected with one-inch boards. (f) In addition to the above protection, there shall be provided a one-quarter-inch steel stop plate, directly in the rear of targets, extending not less than eight (8) inches beyond the outer ring of the bull's-eye, and inclined towards the firing position at an angle of forty-five (45) degrees. The stop plate shall be housed, on sides and top, with corrugated sheet metal extending not less than one (1) foot beyond the top edge of the plate. At the base of the inclined stop plate there shall be provided a sand box with not less than six (6) inches of sand and of sufficient width so as to absorb all the bullets ricocheted by the stop plate as fired from the firing position. (g) Entrance to that part of the licensed area situated between the firing position and targets shall be protected with thirty-six-inch guard rails or equivalent protection. No person except the person in charge shall be permitted within the above-described area during the progress of firing.
(Code 1963, Ch. 3, art. 17, § 10 [Ord. No. 72-4, § 1, 1-24-72])
Ask a question about Killeen law
Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.
