§ 8-181 — Amendments
Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 8-181
Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/9a5a9acd-42fb-4580-bda3-68392a81e5b7
Sec. 8-181. - Amendments.
The following sections of the International Building Code, 2024 Edition, together with Appendices C [Group U—Agricultural Buildings], F [Rodent Proofing], H [Signs], I [Patio Covers], K [Administrative Provisions (Electrical)] and amendments, are hereby amended to read as follows: (1) Section 101.1 of the International Building Code, 2024 Edition, is amended to read as follows: "101.1 Title. These regulations shall be known as the building code of the City of Killeen, Texas, hereinafter referred to as "this code." (2) Section 103.1 of the International Building Code, 2024 Edition, is amended to read as follows: "103.1 Creation of enforcement agency. The Killeen Building Inspections Division is hereby created, and the official in charge thereof shall be known as the building official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code.'" (3) Section 105.2 of the International Building Code, 2024 Edition, is amended by deleting Building, item 6 and amending Building, items 1 and 2 to read as follows: "Building: 1. One-story detached accessory structures used as tool and storage sheds, playhouses, and similar uses, provided the floor area does not exceed 20 square feet. 2. Fences not over 2 feet high." (4) Section 107.1 of the International Building Code, 2024 Edition, is amended to read as follows: "107.1 General. Submittal documents consisting of construction documents, statement of special inspections, geotechnical report and other data shall be submitted in a digital format with each permit application. The construction documents shall be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed. Where special conditions exist, the building official is authorized to require additional construction documents to be prepared by a registered design professional. The design professional shall be an architect or engineer legally registered under the laws of this state regulating the practice of architecture or engineering and shall affix his official seal to said drawings, specifications, and accompanying data, for the following: 1. Group A - assembly occupancies with a design occupant load of 100 or more persons. 2. Group E - educational occupancies with a design occupant load over 50. 3. All group H - hazardous and I - institutional occupancies. 4. Projects that require engineer sealed drawings and details: a. As required by state law. b. Structural repair projects, including foundation repair of slab on grade structures. c. Masonry columns or walls; retaining walls; all over four (4) feet in overall height. Exception: The building official is authorized to waive the submission of construction documents and other data not required to be prepared by a registered design professional if it is found that the nature of the work applied for is such that reviewing of construction documents is not necessary to obtain compliance with this code." (5) Section 110 of the International Building Code, 2024 Edition, is amended by adding subsections 110.7.1, 110.7.2, and 110.7.3 to read as follows: "110.7.1 Reinspection. Where any work or installation does not pass any initial inspection, the necessary corrections shall be made so as to achieve compliance with this code. The work or installation shall then be resubmitted to the code official for reinspection. A fee shall be paid to the department for each failed inspection. 110.7.2 Subsequent reinspection. Where any work or installation does not pass a reinspection, the necessary corrections shall be made so as to achieve compliance with this code. The work or installation shall then be resubmitted to the code official for a subsequent reinspection. A fee shall be paid to the department prior to each subsequent failed inspection. A failed inspection fee shall be paid to the department prior to any subsequent inspection. 110.7.3 Requirements prior to inspections. No inspection for new commercial or new residential construction shall occur if any of the following are not placed at each permitted construction site: 1. Trash receptacle. Such trash receptacle shall be sufficient in size for the project but not smaller than 24 square feet by 4 feet in height with openings no larger than 9 square inches and must be capable of containing construction debris. Such receptacles must be properly maintained and serviced. 2. Project address number posted and visible from street. 3. Construction worker toilet facilities shall be provided as required in 311.1 of the 2024 IPC." (6) Section 113 of the International Building Code, 2024 Edition, is amended by amending the title and section 113.1 to read as follows and by deleting sections 113.2 through 113.4: "SECTION 113 BOARD OF ADJUSTMENT 113.1 General. The City of Killeen Board of Adjustment, as established in Section 31-66 of the Code of Ordinances, City of Killeen, shall hear and decide appeals of orders, decisions or determinations made by the building official relative to the application and interpretation of this code. Where board of appeals appears in this code, it shall hereinafter read Board of Adjustment." (7) Section 115 of the International Building Code, 2024 Edition, is amended by adding section 115.5 to read as follows: "115.5 Project nuisances. A stop work order may be issued if any of the following occur: 1. Construction litter and debris not kept in an approved receptacle designed in a manner so as not to allow it to be blown, carried, or deposited by the wind upon any private or public property or any right-of-way. 2. Project address is not posted or visible from the street or the construction worker toilet facility missing or not in sanitary condition. 3. Excessive construction noise in violation of chapter 16 - miscellaneous provisions and offenses of the Killeen Code of Ordinances." (8) Section 406.7.2 of the International Building Code, 2024 Edition, is amended to read as follows: "406.7.2 Canopies. Canopies under which fuels are dispensed shall have a clear, unobstructed height of not less than 14 feet 0 inches (4,267.2 mm) to the lowest projecting element in the vehicle drive through area. [The remaining section in the code remains in effect and is not amended]. (9) Chapter 10 of the International Building Code, 2024 Edition, is amended by adding section 1006.3.4.6, Single stairway exit for apartment buildings to read as follows: 1006.3.4.6. An apartment building meeting the requirements listed in Texas Government Code Section 214.301(b) is permitted to have a single stairway, (10) Chapter 11 of the International Building Code, 2024 Edition, is amended by deleting sections 1103 through 1112 in their entirety, and amending section 1102.1 to read as follows: "1102.1 Design. Buildings and facilities shall be designed and constructed in accordance with the Texas Accessibility Standards (TAS) of the Architectural Barriers Act. Buildings subject to the requirements of the AS are described in Title 16 Texas Administrative Code Section 68.20. Exception: Buildings regulated under State Law and built-in accordance with State certified plans, including any variances or waivers granted by the State, shall be deemed to be in compliance with the requirements of this chapter." (11) Section 1612.3 of the International Building Code, 2024 Edition, is amended to read as follows: "1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the governing authority shall adopt a flood hazard map and supporting data. The flood hazard map shall include, at a minimum, areas of special flood hazard as identified by the Federal Emergency Management Agency in an engineering report entitled "The Flood Insurance Study for the City of Killeen, effective September 26, 2008" as amended or revised with the accompanying Flood Insurance Rate Map (FIRM) and Flood Boundary and Floodway Map (FBFM) and related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. (REF. Chapter 12 Flood Damage Prevention of the City of Killeen's Code of Ordinances)"
(Ord. No. 02-24, § I, 5-28-02; Ord. No. 06-18, § I, 2-14-06; Ord. No. 09-016, § I, 2-24-09; Ord. No. 11-009, § I, 2-8-11; Ord. No. 15-061, § I, 10-27-15; Ord. No. 18-043 , § I, 11-27-18; Ord. No. 22-004, § I, 1-25-22; Ord. No. 25-068, § I, 12-2-25)
Ask a question about Killeen law
Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.
