§ 8-191 — Same—Amendments
Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 8-191
Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/0e0e5519-0a29-43b0-81c6-56a968037379
Sec. 8-191. - Same—Amendments.
The following sections of the International Residential Code for One- and Two-Family Dwellings, 2024 Edition and amendments, are hereby amended to read as follows: (1) Section R101.1 of the International Residential Code for One- and Two-Family Dwellings, 2024 Edition, is amended to read as follows: "R101.1 Title. These provisions shall be known as the Residential Code for One- and Two-Family Dwellings, of the City of Killeen, hereinafter referred to as "this code." (2) Section R105.1 of the International Residential Code for One- and Two-Family Dwellings, 2024 Edition, is amended by adding Section R105.1.1 to read as follows: "R105.1.1 Structural Repairs. A permit is required to perform structural repairs to buildings covered by this code including foundation repair projects." (3) Section R105.2 of the International Residential Code for One- and Two-Family Dwellings, 2024 Edition, is amended by deleting Building, items 5 and 10 and amending Building, items 1 and 2 to read as follows: "Building: 1. One-story detached accessory structures used as tool and storage sheds, playhouses, and similar uses, provided the floor area does not exceed 20 square feet (3.71 m2). 2. Fences not over 2 feet high." (4) Section R106.1 of the International Residential Code for One- and Two-Family Dwellings, 2024 Edition, is amended by adding Section R106.1.1.1 to read as follows: "R106.1.1.1 Submittal Documents. Engineered documents are required to perform structural repairs or structural changes to buildings covered by this code to include foundation slab repair projects; including masonry or concrete columns or walls or retaining walls, all over four (4) feet in height." (5) Section R109.4 of the International Residential Code for One- and Two-Family Dwellings, 2024 Edition, is amended by adding subsections R109.4.1, R109.4.2, and R109.4.3 to read as follows: "R109.4.1 Reinspection. Where any work or installation does not pass any initial inspection, the necessary corrections shall be made so as to achieve compliance with this code. The work or installation shall then be resubmitted to the code official for reinspection. A failed inspection fee shall be paid to the department for each failed inspection. R109.4.2 Subsequent reinspection. Where any work or installation does not pass a reinspection, the necessary corrections shall be made so as to achieve compliance with this code. The work or installation shall then be resubmitted to the code official for a subsequent reinspection. A failed inspection fee shall be paid to the department prior to any subsequent inspection. R109.4.3 Requirements prior to inspections. No inspection for new residential construction shall occur if any of the following are not placed at each permitted construction site: 1. Trash receptacle. Such trash receptacle shall be sufficient in size for the project but not smaller than 24 square feet by 4 feet in height with openings no larger than 9 square inches and must be capable of containing construction debris. Such receptacles must be properly maintained and serviced. 2. Project address number posted and visible from street. 3. Construction worker toilet facilities shall be provided as required in R306.5 of the 2024 IRC." (6) Section R112 of the International Residential Code for One- and Two-Family Dwellings, 2024 Edition, is amended by amending the title and section R112.1, to read as follows and by deleting sections R112.2 through R112.4: "SECTION R112 BOARD OF ADJUSTMENT R112.1 General. The City of Killeen Board of Adjustment, as established in Section 31-66 of the Code of Ordinances, City of Killeen, shall hear and decide appeals of orders, decisions, or determinations made by the building official relative to the application and interpretation of this code. Where board of appeals appears in this code, it shall hereinafter read Board of Adjustment." (7) Section 114.1 of the International Residential Code for One and Two-Family Dwellings, 2024 Edition, is amended by adding section 114.1.2 to read as follows: "114.1.2 Project nuisances. A stop work order may be issued if any of the following occur: 1. Litter not kept in an approved receptacle designed in a manner so as not to allow it to be blown, carried, or deposited by the wind upon any private or public property or right-of-way. 2. Project address is not posted or visible from the street or the construction worker toilet missing or not in sanitary condition. 3. Excessive construction noise in violation of chapter 16 - miscellaneous provisions and offenses of the Killeen Code of Ordinances." (8) Section R301.2 of the International Residential Code for One-and Two-Family Dwellings, 2024 Edition, is amended by inserting the appropriate design criteria in Table R301.2 as follows: Ground Snow Load | Wind Speed d (mph) | Seismic Design Category f 5 lb/ft 2 | 115 (3-sec-gust) | A Subject to damage from Weathering a | Frost line depth b | Termite c | Decay d | Winter Design Temp f | Flood Hazards g Moderate | 4" | Moderate to heavy | Slight to moderate | 26° F | Local code (9) Section R326 of the International Residential Code for One- and Two-Family Dwellings, 2024 Edition, is amended by adding section R326.5 to read as follows: "R326.5 Toilet facilities for workers. Each contractor shall provide toilet facilities for construction workers and such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the non-sewer type shall conform to ANSI Z4.3. The path of travel to required facilities shall not exceed a distance of 150 feet (45.5 m)." (10) Section R309.2 of the International Residential Code for One-and Two-Family Dwellings, 2024 Edition, is amended by deleting section 313.2 One- and two-family dwellings automatic fire sprinkler systems in its entirety; in accordance with Texas Occupational Code section 1301.55(i).
(Ord. No. 02-24, § I, 5-28-02; Ord. No. 06-18, § I, 2-14-06; Ord. No. 09-016, § I, 2-24-09; Ord. No. 11-009, § I, 2-8-11; Ord. No. 15-061, § I, 10-27-15; Ord. No. 18-043, § I, 11-27-18; Ord. No. 22-004, § I, 1-25-22; Ord. No. 25-068, § I, 12-2-25)
Ask a question about Killeen law
Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.
