§ 8-220 — General installation requirements for residential and commercial buildings and structures
Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 8-220
Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/06b63ae0-0864-4330-bb0a-af3a19c2fea1
Sec. 8-220. - General installation requirements for residential and commercial buildings and structures.
(a) All electrical construction and all materials and appliances used in connection with the installation, maintenance, and operation of electrical wiring, apparatus, or equipment for the utilization of electrical energy for light, heat or power shall conform to the rules and regulations of this section, the adopted electrical code, and in harmony with the electrical service guidelines of the local electrical utility provider. (b) Abandoned wiring. Whenever new wiring is replacing old wiring, the old wiring shall be completely removed where possible. Abandoned wiring that cannot be removed shall be rendered unusable for future use before final approval shall be given for the new wiring. (c) Additions to existing wiring. Where additions or extensions are made, and part of the existing wiring remains in use, and if defects exist in same, the existing wiring must be corrected and shall meet standards for new work. (d) Electrical service upgrade required. The electrical service shall be upgraded on a structure when electrical power is disconnected for any of the following conditions: (1) Dangerous or unsafe electrical hazards; (2) Substantial damage to electrical service over fifty percent (50%); or (3) Loss of electrical power for a period of one (1) year or longer. (e) Electrical system upgrade required (total rewire). The electrical system shall be upgraded on a structure when any of the following occur: (1) Dangerous or unsafe electrical hazards. (2) Substantial damage to electrical system over fifty percent (50%). (3) Building change of use from residential use to commercial use. For the purpose of this section, apartment dwellings are considered residential use and hotel/motel structures are considered commercial use. (f) Service masts as supports. In addition to the requirements in the NEC, section 230-28, all service masts installed as support for service-drop conductors shall meet the following: (1) Service conduit extending through the roof and used for a service support shall be sealed at the roof with an approved flashing and extend a minimum of thirty of thirty-six (36) inches above the roof. Such service conduit shall be anchored just before entering the roof. (g) Services—General. In addition to the requirements in the NEC, section 230, all services installed shall meet the following: (1) All entrance service conductors shall be enclosed in galvanized conduit or electrical metallic tubing. A minimum of one and one-quarter inch (1-1/4") conduit shall be used for service other than for service masts. (2) Length of outside service wire extension beyond service weatherhead shall not be less than (1) one foot. (3) Unless otherwise allowed in section 230 of the adopted NEC, tenant or lease space buildings shall have only (1) electrical service meter allowed for each individual tenant space. (4) Reconfigured tenant spaces that combine interior spaces, through interior openings, doors, or other access points, of two or more originally separate tenant spaces in order to serve one (1) tenant exclusively shall be required to remove all but one (1) electrical service meter. (h) Main disconnects. Service entrance conductors hereafter installed on all buildings, shall require a single main disconnect or manual shunt-trip device located outside the building or structure. When a remote shunt-trip button is installed, it shall be located on the exterior of the building or structure and shall have a visual indication that the service has been disconnected when the trip has been activated. The shunt-trip button shall be in a sturdy, exterior cabinet that can be secured with a padlock. The cabinet shall be permanently marked on the exterior, stating "shunt-trip disconnect."
(Ord. No. 02-24, § I, 5-28-02; Ord. No. 06-18, § I, 2-14-06; Ord. No. 09-016, § I, 2-24-09; Ord. No. 11-009, § I, 2-8-11; Ord. No. 15-061, § I, 10-27-15; Ord. No. 18-043, § I, 11-27-18; Ord. No. 22-004, § I, 1-25-22; Ord. No. 25-068, § I, 12-2-25)
Ask a question about Killeen law
Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.