§ 8-340 — Aircraft noise attenuation requirements
Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 8-340
Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/51b45214-3906-4b5c-a409-474641bafd0f
Sec. 8-340. - Aircraft noise attenuation requirements.
I. Aircraft Noise Zones. A. For the purposes of this code, certain sections of the city are declared to be and are hereby established as zones subject to significant noise from aircraft. These zones shall be known and designated as the 65-70 LDN Noise Zone and the Over 70 LDN Noise Zone, as such are identified within the 1991 Killeen municipal airport master plan. B. These noise zones shall include, and be limited to, such territory or portions of the city as is designated and shown within aircraft noise impact maps of the 1991 Killeen Municipal airport master plan, which are hereby incorporated into this code and made a part hereof for all intents and purposes. II. Noise Level Reduction Standards. A. Plans for the construction of buildings or structures within noise zones shall be certified as achieving at least the outdoor to indoor noise level reductions as measured in decibels within the building as follows: BUILDING USE | 65-70 LDN NOISE ZONE | OVER 70 LDN NOISE ZONE RESIDENTIAL Residential within each unit including transient lodgings | 25 | 30 PUBLIC USE Schools, Hospitals, Nursing Homes | 25 | 30 III. Certification of Plans Prior to Issuance of Building Permit. A. The building official shall not issue a building permit for any buildings or structures within the noise zones established by this ordinance unless: 1. The plans and specifications accompanying the application for said permit are certified by a bona fide acoustical consultant as meeting the Noise Level Reduction standards required by this ordinance; or 2. By certification of the building official that the following construction standards have been met: a. Building Requirements for a Minimum Noise Level Reduction of 25 dB (within the 65-70 LDN): Exterior Walls Masonry walls shall be equivalent in weight to six-inch minimum light-weight concrete block. At least one surface shall be painted or plastered. A furred interior wall is not required on the inside of masonry walls. Siding-on-sheathing, stucco or brick veneer shall be installed on the outside of minimum 4-inch nominal deep studs. Interior wall surface of exterior wall shall be minimum half-inch gypsum board or plaster installed on the inside of the wall studs. Continuous sheathing as required by the code shall cover the exterior said of the wall studs behind wood, asphalt or aluminum siding. The sheathing shall be minimum half-inch thick. Sheathing boards or panels shall be butted tightly and covered on the exterior with overlapping and airtight building paper when wood sheathing is used. Brick veneer, masonry blocks or stucco walls shall be constructed airtight except as otherwise required by the code. All surface joints shall be grouted or caulked airtight. Weep Holes shall be installed in the bottom vertical joint a maximum of eight foot on center. Penetration of wall by pipes or ducts shall be caulked or filled with mortar. Windows Glass of single-glazed windows shall be minimum three-sixteenths of an inch thick. Glass of double-glazed windows shall be of standard manufacturers' thickness and separation of not less than one-quarter inch. All operable windows in these dwellings shall contain hinged-type sash or double-hung sash. The sash shall be rigid and weather stripped with an efficiently airtight, flexible nonmetallic material that is compressed airtight when the window is closed. Horizontally sliding sash windows may be used only if the sash is weather stripped with an efficiently airtight gasket and if the window has a laboratory sound transmission rating of STC-28 or greater. Glass for fixed-sash windows shall be set and sealed in an airtight non-hardening glazing compound or in an elastomer gasket. The perimeter of window frames shall be sealed airtight to the exterior wall construction and all gaps between the window frame and the wall framing shall be filled with an insulating foam or stuffed with batt insulation. Doors All exterior doors shall be one and three-quarter inch solid core wood or metal clad door and shall be fully weather stripped in an airtight manner and all gaps between the window frame and wall framing shall be filled with an insulating foam or stuffed with batt insulation. Sliding doors may be used if the operable sash is weather stripped with an efficient airtight gasket and if the door has a laboratory sound transmission rating of STC-28 or greater. Glass of sliding doors shall be minimum three-sixteenths of an inch thick. The perimeter of door frames shall be sealed airtight to the exterior wall construction. Ceilings Minimum half inch thick gypsum board or plaster ceilings shall be provided below attic space or roof rafters or roof construction less than eight psf. A minimum thermal resistance ® factor of nineteen shall be provided above the ceiling between the joists. Insulation in attic space shall have no paper or foil covering on the face exposing to the attic. Ventilation Mechanical ventilation shall be provided of a type and design to provide adequate environmental comfort with all doors and windows closed during all seasons. Window and through-the-wall ventilation units shall not be allowed. Vent openings in attic or crawl spaces shall be minimum in number and size to provide proper ventilation. A "vent" shall mean a conduit or passageway, vertical or nearly so, for conveying products of combustion to the outside atmosphere. Return air duct lining shall be one-inch minimum coated glass fiber duct liner. Fireplaces shall be provided with well-fitted dampers. b. Building Requirements for a Minimum Noise Level Reduction of 30 dB (within the 70 and above LDN): Exterior Walls Masonry block units shall be equivalent in weight to minimum six-inch dense concrete block. At least one surface shall be painted or plastered. A furred interior wall is not required on the inside of masonry walls. Siding-on-sheathing, stucco or brick veneer shall be installed on the outside of minimum four-inch nominal deep studs. Interior wall surface of exterior walls shall be minimum five-eighth inch gypsum board or plaster installed on the inside of the wall studs. Continuous sheathing as required by the code shall cover the exterior side of the wall studs behind wood, asphalt or aluminum siding. The sheathing shall be minimum half-inch thick. The weight of the sheathing and facing shall be at least four psf. Sheathing boards or panels shall be butted tightly and covered on the exterior with overlapping and airtight building paper. The top and bottom edges of the sheathing shall be sealed airtight. A minimum thermal resistance R-value of thirteen shall be provided in the cavity space behind the exterior sheathing and between wall studs with glass fiber or mineral wool. Brick veneer, masonry blocks or stucco walls shall be constructed airtight except as otherwise required by the code. All surface joints shall be grouted or caulked airtight. Penetration of wall by pipes or ducts shall be caulked or filled with mortar. Windows Single-glazed windows may be used if the window is fixed and if the glazing is acoustical glass with a laboratory sound transmission rating of minimum STC-35. Glass of double-glazed windows shall be minimum of three-sixteenths of an inch in thickness. Panes of glass shall be separated by a minimum quarter-inch air space and shall not be equal in thickness. Glass of triple-glazed windows shall be of standard manufacturer's width and separation. Double and triple glazed windows shall contain fixed sash or efficiently weather-stripped operable sash. The sash shall be rigid and weather stripped with an efficiently airtight material that is compressed airtight when the window is closed. Glass of fixed-sash windows shall be set and sealed in an airtight non-hardening glazing compound or in a elastomer gasket. The perimeter of window frames shall be sealed airtight to the exterior wall construction and all gaps between the window frame and the wall framing shall be filled with an insulating foam or stuffed with batt insulation. The total area of glass of both windows and doors in sleeping spaces shall not exceed twenty percent of the net floor area. Doors Double-door construction is required for all door openings to the exterior. If doors are separated by a vestibule of three-foot minimum depth, each door shall be one and a half-inch minimum solid core wood or metal clad door. One door shall be weather stripped in an airtight manner. The other door shall be tightly fitted to the door frame or shall be weather stripped. If no vestibule is used, a one and three-quarters of an inch minimum solid core wood door may be used in series with a storm door. Both doors shall be weather stripped in an airtight manner. Single-frame sliding glass doors shall not be used. The glass of double sliding doors shall be separated by a minimum one-quarter of an inch airspace. Each sliding frame shall be provided with an efficiently airtight weatherstripping material. Glass of storm and sliding doors shall be minimum three sixteenths of an inch. Glass of double sliding doors shall not be equal in thickness. The perimeter of door frames shall be sealed airtight to the exterior wall construction. Roofs Roof sheathing shall be minimum three-quarter inch thick continuous plywood. Spaced board-sheathing shall not be used. Roof sheathing joints shall be sealed airtight and shall be covered with overlapping, airtight building paper. Exposed roof decks shall be minimum two-inch-thick wood or concrete, and the total weight of the roof construction shall be a minimum of twelve psf. Ceilings A minimum half inch thick gypsum board or plaster ceiling shall be provided below attic spaces or below the roof rafters or roof decks less than two inches thick and weighing less than twelve psf. The ceiling shall be a minimum of twelve inches below the roof sheathing. A minimum thermal resistance R-value of twenty-three shall be provided above the ceiling between the joists. Insulation in attic space shall have no paper or foil covering on the face exposing to the attic. Ventilation Mechanical ventilation shall be provided of a type and design to provide adequate environmental comfort with all doors and windows closed during all seasons. Window and through-the-wall ventilation units shall not be used. Vent openings in attic or crawl spaces shall be minimum in number and size. The openings shall be provided with five-foot long transfer ducts containing at least one ninety-degree elbow and internal acoustical lining. Ventilation ducts connecting the interior space to the outdoor or attic space shall contain at least ten-foot-long internal duct lining plus one limited ninety degree elbow. Duct lining shall be coated glass fiber duct liner of one-inch minimum thickness. Operational vented fireplaces shall not be used. Building heating units with flues or combustion air vents shall be located in a closet or room closed off from the occupied space by doors. Doors to mechanical equipment areas shall be one and three-quarter inch minimum solid core wood or twenty-gauge steel hollow metal and shall be fully weather stripped. Other All sleeping spaces shall be provided with either carpeting or an acoustically treated ceiling. Through-the wall/door mailboxes shall not be allowed. B. Bona fide acoustical noise consultants shall include members of the National Council of Acoustical Consultants and others who are approved by the building official, such approval being based on the demonstration of competence and credentials in the area of architectural acoustics. C. A building or structure which is located partly within a noise zone and partly without, or located partly within one noise zone and partly within another noise zone shall be considered to be entirely within the most restrictive of the noise zones within which it is located.
(Ord. No. 90-42, § I (5-8-2), 5-8-90; Ord. No. 93-25, § I, 4-13-93; Ord. No. 25-068, § I, 12-2-25)
Ask a question about Killeen law
Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.