§ 15-144 — Private pool/spa barrier requirements

Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Code of Ordinances § 15-144

Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/873d15ba-cc4e-4671-94fa-7035b85f3c63

Sec. 15-144. - Private pool/spa barrier requirements.

(a) The top of the barrier shall be at least forty-eight (48) inches (one thousand two hundred nineteen (1,219) mm) above grade measured on the side of the barrier which faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of the barrier shall be two (2) inches (fifty-one (51) mm) measured on the side of the barrier, which faces away from the swimming pool. Where the top structure is above grade, such as an above-ground pool, the barrier may be at ground level, such as the pool structure, or mounted on top of the pool structure. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be four (4) inches (one hundred two (102) mm). (b) Openings in the barrier shall not allow passage of a four-inch-diameter sphere. (c) Solid barriers which do not have openings, such as masonry or stonewall, shall not contain indentation or protrusions except for normal construction tolerance and tooled masonry joints. (d) When the barrier composed of horizontal and vertical members and the distance between the tops of the horizontal member is less than forty-five (45) inches (one thousand one hundred forty-three (1,143) mm), the horizontal member shall be located on the swimming pool side of the fence, or shall be so constructed as to not provide a climbable surface. Spacing between vertical members shall not exceed one and three-fourths (1.75) inches (forty-four (44) mm) in width. Where there are decorative cutouts within vertical members, spacing with in cutouts shall not exceed one and three-fourths (1.75) inches (forty-four (44) mm) in width. (e) Where the barrier is composed of horizontal and vertical members and the distance between the top of the horizontal members is forty-five (45) inches (one thousand one hundred forty-three (1,143) mm) or more, spacing within the cutouts shall not exceed four (4) inches (one hundred two (102) mm). Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed one and three-fourths (1.75) inches (forty-four (44) mm) in width. (f) Maximum mesh size for chain link fences shall be a one and one-fourth-inch (thirty-two (32) mm) square unless the fence is provided with slats fastened at the top or the bottom which reduce the openings to not more than one and three-fourths (1.75) inches (forty-four (44) mm). (g) Where the barrier is composed of diagonal members, such as a lattice fence, the maximum opening formed by the diagonal members shall not be more [than] one and three-fourths (1.75) inches (forty-four (44) mm). (h) Access gates shall comply with the requirements of section AG105.2, items 1 through 7, and shall be equipped to accommodate a locking device. Pedestrian-access gates shall open outward away from the pool and shall be self-closing and have a self-latching device. Gates other than pedestrian-access gates shall have a self-latching device. Where the release mechanism of the self-latching device is located less than fifty-four (54) inches (one thousand three hundred seventy-two (1,372) mm) from the bottom of the gate, the release mechanism and openings shall comply with the following: (1) The release mechanism shall be located on the pool side of the gate at least six (6) inches (one hundred fifty-two (152) mm) below the top of the gate, and (2) The gate and barrier shall have not opening greater than 0.5 inches (12.7 mm) within eighteen (18) inches (four hundred fifty-seven (457) mm) of the release mechanism. (i) Where a wall of a dwelling serves a part of the barrier one of the following conditions shall be met: (1) The pool shall be equipped with a powered safety cover in compliance with ASTM F1346; or (2) All doors with direct access to the pool through that wall shall be equipped with an alarm which produces an audible warning when the door and its screen, if present, are opened. The alarm shall sound continuously for a minimum of thirty (30) seconds immediately after the door is opened and be capable of being heard throughout the house during normal household activities. The alarm shall automatically reset under all conditions. The alarm system shall be equipped with a manual means, such as touchpad or switch, to temporarily deactivate the alarm for a single opening, such deactivation switch to temporarily deactivate the alarm for a single opening. Such deactivation shall last for not more than fifteen (15) seconds. The deactivation switch(es) shall be located at least fifty-four (54) inches (one thousand three hundred seventy-two (1,372) mm) above the threshold of the door; or (3) Other means of protection, such as self-closing doors with self-latching devices, which are approved by the governing body, shall be acceptable so long as the degree of protection afforded is not less than the protection afforded by subsections (h)(1) and (2) described above. (j) Where an above-ground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure and the means of access is a ladder or steps, then: (1) The ladder or steps shall be capable of being secured, locked or removed to prevent access, or (2) The ladder or steps shall be surrounded by a barrier which meets the requirements of section AG105.2, items 1 and 9. When the ladder or steps are secured, locked or removed, any opening created shall not allow the passage of a four-inch-diameter sphere. (k) Deleted. (l) Swimming pool/spa barrier information shall be provided on drawings; refer to glazing requirements of chapter 3, section R308 of 2006 International Residential Codebook (IRC) and ordinances. (Impact-resistance glazing is less than sixty (60) inches above the spa/poolside of the glazing.) (m) Where there is an existing fence, it is the swimming pool/spa contractor's responsibility to upgrade the swimming pool/spa barrier requirements. (n) Private, public, semipublic, and spas shall comply with the Texas Department of Health Standards for Public Swimming Pools and Spas (Texas Administrative Code, title 25). For copies of the standard, contact the state at 1-800-226-7199 or at http://www.sos.state.tx.us/tac. (o) Manufacturer's specifications shall be required for diving equipment, including swimming pool type and maximum height above the water. (p) All swimming pools and spas shall comply with the 2006 International Energy Conservation Code, sections 504.3—504.3.3. (q) All swimming pool/spa contractors must be registered with the city to acquire permits. To register the following requirements must be met. All contractors: (1) Must present proof of having five (5) years' experience in the construction of swimming pools; (2) Must present proof of having passed swimming pool contractor examination; (3) Must present proof of being certified pool operators within one (1) year of the adoption of the article; (4) Must present proof of liability insurance of five hundred thousand dollars ($500,000.00) with increments of two hundred fifty thousand dollars ($250,000.00) for the next two (2) years until insurance of no less than one million dollars ($1,000,000.00) is reached; and (5) Must be current with all city taxes. Annual registration fee will be fifty dollars ($50.00). Only registered pool contractors will be eligible to get permits.

(Ord. No. 2008-O-057, § 1, 4-7-08; Ord. No. 2008-O-099, 5-19-08)

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.