§ 24-69.7 — PROVISIONS FOR FLOOD HAZARD REDUCTION

Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Land Development Code § 24-69.7

Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/22498b8e-13cf-4925-8576-63d007ac6fe4

Section 24-69.7 - PROVISIONS FOR FLOOD HAZARD REDUCTION

A. General Standards. In all areas of special flood hazards, the following provisions are required for all new construction and substantial improvements: (1) All new construction or substantial improvements shall be designed (or modified) and adequately anchored to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; (2) All new construction or substantial improvements shall be constructed by methods and practices that minimize flood damage; (3) All new construction or substantial improvements shall be constructed with materials resistant to flood damage; (4) All new construction or substantial improvements shall be constructed with electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities that are designed (example: floodproofing) and/or located (example: elevated eighteen (18) inches (or more) above the BFE) so as to prevent water from entering or accumulating within the components during conditions of flooding; (5) All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system; (6) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the system and discharge from the systems into flood waters; and (7) On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. B. Specific Standards. In all areas of special flood hazards where base flood elevation data has been provided as set forth in: (i) Section 24-69.3B, (ii) Section 24-69.4B.(8), or (iii) Section 24-69.5C.(3), the following provisions are required: (1) Residential Construction - new construction and substantial improvement of any residential structure shall have the lowest floor (including basement), together with attendant utilities (for example junction boxes, breaker boxes, electrical outlets, switches, plugs, HVAC systems, ale ductwork, hot water heaters or any non-structural system which when inundated with water would make the structure uninhabitable), elevated eighteen (18) inches (or more) above the base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the Floodplain Administrator that the standard of this subsection, as proposed in Section 24-69.4C.(1)a., is satisfied. (2) Nonresidential Construction - new construction and substantial improvements of any commercial, industrial, or other nonresidential structure shall either have the lowest floor (including basement), together with attendant utilities (for example, junction boxes, breaker boxes, electrical outlets, switches, plugs HVAC systems, ale ductwork, hot water heaters or any non-structural system which when inundated with water would make the structure uninhabitable), elevated eighteen (18) inches (or more) above the base flood level or together with attendant utility and sanitary facilities, be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy, A registered professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this subsection. A record of such certification, which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed, shall be maintained by the Floodplain Administrator. (3) Enclosures - new construction and substantial improvements, with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access, or storage in a location other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: (a) At least two (2) openings on separate walls with a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding shall be provided. (b) The bottom of all openings shall be no higher than one (1) foot above grade. (c) Openings may be equipped with screens, louvers, valves, or other coverings or devices, provided that they permit floodwaters' automatic entry and exit. (4) Manufactured Homes. (a) All manufactured homes must be placed within Zone A on a community's FHBM or FIRM and shall be installed using methods and practices that minimize flood damage. For this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Anchoring methods may include but are not limited to using over-the-top or frame ties to ground anchors. This requirement is in addition to applicable State and local anchoring requirements for resisting wind forces. (b) Require that manufactured homes that are placed or substantially improved within Zones A1-30, AH, and AE on the community's FIRM on sites: (i) Outside of a manufactured home park or subdivision, (ii) In a new manufactured home park or subdivision, (iii) In an expansion to an existing manufactured home park or subdivision, or (iv) In an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as a result of a flood, the home must be elevated on a permanent foundation such that the lowest floor of the home is elevated eighteen (18) inches (or more) above the base flood elevation and securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. (c) Require that manufactured homes be placed or substantially improved on sites in an existing manufactured home park or subdivision with Zones A1-30, AH, and AE on the community's FIRM that are not subject to the provisions of paragraph (4) of this section be elevated so that either: (i) The lowest floor of the manufactured home is eighteen (18) inches (or more) above the base flood elevation, and (ii) The manufactured home chassis is properly supported and to be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. Recreational Vehicles - Require that recreational vehicles placed on sites within Zones A1-30, AH, and AE on the community's FIRM either: (i) be on the site for fewer than one hundred eighty (180) consecutive days, or (ii) be fully licensed and ready for highway use, or (iii) meet the permit requirements of Section 24-69.4C.(1), and the elevation and anchoring requirements for "manufactured homes" in paragraph (4) of this section. A recreational vehicle is ready for highway use if it is on its wheels or jacking system. It is attached to the site only by quick disconnect type utilities and security devices and has no permanently attached additions. C. Standards for Subdivision Proposals. (1) All subdivision proposals, including the placement of manufactured home parks and subdivisions, shall be consistent with Sections 24-69.1B. and C. and Section 24-69.2 of this ordinance. (2) All proposals for the development of subdivisions, including the placement of manufactured home parks and subdivisions, shall meet Floodplain Development Permit requirements of Section 24-69.3C., Section 24-69.4C., and the provisions of Section 24-69.5 of this ordinance. (3) Base flood elevation data shall be generated for subdivision proposals and other proposed development, including the placement of manufactured home parks and subdivisions which is greater than fifty (50) lots or five (5) acres, whichever is lesser, if not otherwise provided pursuant to Section 24-69.3B. or Section 24-69.4B.(8) of this ordinance. (4) All subdivision proposals, including the placement of manufactured home parks and subdivisions, shall have adequate drainage provided to reduce exposure to flood hazards. (5) All subdivision proposals, including the placement of manufactured home parks and subdivisions, shall have public utilities and facilities such as sewer, gas, electric, and water systems located and constructed to minimize or eliminate flood damage. D. Standards for Areas of Shallow Flooding (AO/AH Zones). Located within the areas of special flood hazard established in Section 24-69.3B., are areas designated as shallow flooding. These areas have special flood hazards associated with flood depths of one (1) to three (3) feet where a clearly defined channel does not exist, where the path of flooding is unpredictable, and where velocity flow may be evident. Such flooding is characterized by ponding or sheet flow; therefore, the following provisions apply: (1) All new construction and substantial improvements of residential structures have the lowest floor (including basement) elevated eighteen (18) inches (or more) above the base flood elevation or the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM (at least three (3) feet if no depth number is specified). (2) All new construction and substantial improvements of non-residential structures: (a) Have the lowest floor (including basement) elevated to or above the base flood elevation or the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM (at least three (3) feet if no depth number is specified), or (b) Together with attendant utility and sanitary facilities be designed so that below the base specified flood depth in an AO Zone, or below the Base Flood Elevation in an AH Zone, level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads of effects of buoyancy. (3) A registered professional engineer or architect shall submit a certification to the Floodplain Administrator that the standards of subsection D. herein as proposed in Section 24-69.4 Care satisfied. (4) Adequate drainage paths around slope structures are required within Zones AH or AO to guide floodwaters around and away from proposed structures. E. Floodways. Floodways located within areas of special flood hazard established in Section 24-69.3B., are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of flood waters, which carry debris, potential projectiles, and erosion potential, the following provisions shall apply: (1) Encroachments are prohibited, including fill, new construction, substantial improvements, and other development within the adopted regulatory floodway, unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment would not result in any increase in flood levels within the community during the occurrence of the base flood discharge. (2) If Section 24-69.5E.(1) above is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of Section 24-69.5. (3) Under the provisions of 44CFR Chapter 1, Section 65.12, of the National Flood Insurance Program Regulations, a community may permit encroachments within the adopted regulatory floodway that would result in an increase in base flood elevations, provided that the community first completes all of the provisions required by Section 65.12. F. Severability. If any section, clause, sentence, or phrase of this Ordinance is held to be invalid or unconstitutional by any court of competent jurisdiction, then said holding shall in no way affect the validity of the remaining portions of this Ordinance. G. Penalties for Noncompliance. No structure or land shall hereafter be constructed, located, extended, converted, or altered without full compliance with the terms of this court order and other applicable regulations. Violation of the provisions of this court order by failure to comply with any of its requirements (including violations of conditions and safeguards established in connection with conditions) shall constitute a misdemeanor. Any person who violates this court order or fails to comply with any of its requirements shall, upon conviction thereof, be fined not more than five hundred dollars ($500.00) for each violation and, in addition, shall pay all costs and expenses involved in the case. Nothing herein contained shall prevent the City of Laredo from taking such other lawful action as is necessary to prevent or remedy any violation.

(Amended Ord. No. 2019-O-087, § 24.69 (24.69.1—24.69.7), 6/3/19; Ord. No. 2024-O-102, § 1 6-10-24)

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.