For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 24-93.10 — COMMUNICATION TOWERS AND ANTENNAS

Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Land Development Code § 24-93.10

Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/a92816ba-9f2a-4412-b718-995746af2c01

Section 24-93.10 - COMMUNICATION TOWERS AND ANTENNAS

(a) Application Procedures. 1. Application form: The application shall be made on a form approved by the Director of Planning, and shall include the following information: a. The name, address, and telephone number of the applicant and the applicant's agent, if any. Identification of the entities providing the backhaul network for the tower(s) described in the application and other cellular sites owned or operated by the applicant in the municipality; b. A deed and legal description of the property; c. Verification of compliance with FCC, FAA regulations and, if applicable, any other federal or state agencies; d. A notarized statement by the applicant and a sealed set of plans by a qualified engineer, confirming the construction of the tower will accommodate collocation of additional antennas for future users; e. A safety report by a qualified structural engineer establishing the structural integrity of the tower; f. Any information of an engineering nature that the applicant submits, whether civil, mechanical, or electrical, shall be certified by a licensed professional engineer; g. A description of the suitability of the use of existing towers, other structures or alternative technology not requiring the use of towers or structures to provide the services to be provided through the use of the proposed new tower; h. A description of the feasible location(s) of future towers or antennas within the City of Laredo based upon existing physical, engineering, technological or geographical limitations in the event the proposed tower is erected; i. The separation distance from other towers described in an inventory of existing sites shall be shown on an updated site plan or map. The applicant shall also identify the type of construction of the existing tower(s) and the owner/operator of the existing tower(s). 2. Site plan requirements. The site plan shall include the following information: a. The location, type and height of the proposed tower; b. On-site land uses and zoning, adjacent land uses and zoning (including when adjacent to other municipalities), Master Plan classification of the site and all properties within the applicable separation distances set forth in this section; c. Adjacent roadways, proposed means of access, and parking; d. Setbacks from property lines; e. Elevation drawings of the proposed tower and any other structures; f. Topography; g. The setback distance between the proposed tower and the nearest residential districts as set forth in this section; h. A landscape plan showing specific landscape materials proposed; i. Method of fencing, and finished color and, if applicable, the method of camouflage and illumination; j. Any additional information deemed by the Planning Director to be necessary to assess compliance with this ordinance. (b) Factors to be Considered in Issuance of Special Use Permit Include: 1. Prior to recommending the issuance of a Special Use Permit, the Planning and Zoning Commission shall make findings concerning the following: a. Height of the proposed tower; b. Proximity of the tower to residential structures and residential district boundaries; c. Nature of uses on adjacent and nearby properties; d. Surrounding topography; e. Surrounding tree coverage and foliage; f. Design of the tower, with particular reference to design characteristics that have the effect of reducing or eliminating visual obtrusiveness which may include fencing and screening; g. Access; h. Availability of existing towers, other structures, or alternative technologies not requiring the use of towers or structures. 2. In granting a special use permit, the City Council may impose conditions deemed necessary to minimize any adverse effect of the proposed tower on adjoining properties. (c) Design Standards. (1) Existing Towers, Other Structures, or Alternative Technology. No new tower shall be permitted unless no existing tower, structure or alternative technology that does not require the use of towers or structures can accommodate the applicant's proposed antenna, or a. Existing towers or structures are not located within the geographic area which meet applicant's engineering requirements, or b. Existing towers or structures are not of sufficient height to meet applicant's engineering requirements, or c. Existing towers or structures do not have sufficient structural strength to support applicant's proposed antenna and related equipment, or d. The applicant's proposed antenna would cause electromagnetic interference with the antenna on the existing towers or structures, or the antenna on the existing towers or structures would cause interference with the applicant's proposed antenna, or e. The applicant demonstrates that there are other limiting factors that render existing towers and structures unsuitable, or f. The applicant demonstrates that an alternative technology that does not require the use of towers or structures, such as a cable micro cell network using multiple low-powered transmitters/receivers attached to a wire line system, is unsuitable. (2) Setbacks. The following setback requirements shall apply to all towers for which a special use permit is required: a. Towers must be set back a distance equal to at least seventy-five percent (75%) of the height of the tower from any adjoining lot line. b. Guys and accessory buildings must meet the minimum zoning district setback requirements. (3) Separation from off-site uses/designated areas. a. Tower separation shall be measured from the base of the tower to the lot line of the off-site uses and/or designated areas as specified in Table 1, except as otherwise provided in Table 1. b. Separation requirements for towers shall comply with the minimum standards established in Table 1. TABLE 1 Off-site Zoning District | Separation Distance RS (Residential Suburban District), R-1 (Single Family Residential District), R-1A (Single Family Reduced Area District), R-1MH (Single Family Manufactured), RSM (Residential Suburban Multi-Family District). | 200 feet or 300% height of tower 1 whichever is greater. R-2 (Multi-Family District), R-3 (Mixed Residential District), R-O (Residential/Office District). | 100 feet or 100% height of tower whichever is greater. Non-residentially zoned lands or non-residential uses. | None; only setbacks apply. 1 Separation measured from base of tower. (4) Separation distances between towers. a. Separation distances between towers shall be applicable for and measured between the proposed tower and preexisting towers. The separation distances shall be measured by drawing or following a straight line between the base of the existing tower and the proposed base, pursuant to a site plan, of the proposed tower. The separation distances (listed in linear feet) shall be as shown in Table 2. TABLE 2 Tower Types | Lattice | Guyed | Monopole 75 ft. in Height or Greater | Monopole Less Than 75 ft. in Height Lattice | 5,000' | 5,000' | 1,500' | 750' Guyed | 5,000' | 5,000' | 1,500' | 750' Monopole 75 ft. in Height or Greater | 1,500' | 1,500' | 1,500' | 750' Monopole Less Than 75 ft. in Height | 750' | 750' | 750' | 750' (5) Security fencing. Towers shall be enclosed by security fencing not less than six (6) feet in height and shall also be equipped with an appropriate anti-climbing device. (6) Landscaping. Existing mature tree growth and natural land forms on the site shall be preserved to the maximum extent possible. (7) Buildings or Other Equipment Storage. a. Antennas Mounted on Structures or Roof tops. The equipment cabinet or structure used in association with antennas shall comply with the following: 1. A safety report from a structural engineer shall be provided establishing the structural integrity of the principal support structure. 2. Equipment storage buildings or cabinets shall comply with all applicable building codes. b. Antennas Mounted on Utility Poles or Light Poles shall be subject to franchises as required by law. The equipment cabinet or structure used in association with these antennas shall be located within designated easements or within the public right-of-way as provided in the franchise agreement. In no way shall the equipment cabinet or structure interfere with pedestrian or vehicular circulation and visibility. c. Antennas Located on Towers. The related unmanned equipment structure shall be located in accordance with the minimum yard requirements of the zoning district in which located. (d) Removal of Abandoned Antennas and Towers. Any antenna or tower that is not operated for a continuous period of twelve (12) months shall be considered abandoned, and the owner of such antenna or tower shall remove the same within ninety (90) days of receipt of notice from the City of Laredo notifying the owner of such abandonment. Failure to remove an abandoned antenna or tower within said ninety (90) days shall be grounds to remove the tower or antenna at the owner's expense. If there are two (2) or more users of a single tower, then this provision shall not become effective until all users cease using the tower.

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.