Sec. 13-34. - Permit application.

(a) The permit will be in the name of the owner of the facilities to be constructed. The permit application must be completed and signed by a representative of the owner of the facilities to be constructed. (b) Any person requesting a permit will provide the responsible person with documentation in the format specified by the department, at the time of permit application submittal, describing: (1) The name, telephone number, local address and principal place of business of the owner. (2) The name and day and night telephone numbers of the engineer, foreman, or other person who will be in charge of the construction or repairs for which the permit is requested. (3) The times of the day and total number of days the owner seeks to block the roadway. (4) The proposed location and route of all facilities to be constructed or installed and the owner's plan for public right-of-way construction. For lines longer than 100 feet, the line must be stationed. (5) Three sets of engineering plans, including plan and profile, which will be on a standard engineering scale, acceptable to the department, unless waived by the responsible person. When required by the Texas Engineering Practice Act, as amended, the plans must be sealed by a professional engineer licensed to practice in the State of Texas. (6) A map or site plan drawn to scale on 11-inch × 17-inch or 22-inch × 34-inch paper showing: a. The location of the proposed installation, including GIS or street address information; b. The proximity of the proposed installation to special districts of the city; c. The proximity to schools and municipal parks; and d. The proximity to poles, if any, and depicting the sidewalks, and ramps onto sidewalks required by all applicable regulations, the Texas Accessibility Standards, or other law, including the Americans with Disabilities Act, paved street surface and all existing underground and overhead utilities in the right-of-way and utility easements. (7) Detail of the location of all public right-of-way and utility easements that owner plans to use. (8) Detail of existing utilities located in the public right-of-way, including the city's utilities, in relationship to owner's proposed route. (9) Detail of what owner proposes to construct including size of facilities, materials used, such as pipe size, number of ducts, valves, etc. (10) Detail of plans to remove and replace asphalt or concrete in public rights-of-way. (11) Drawings of any bores, trenches, handholes, manholes, switch gear, transformers, pedestals, etc., including depth located in public right-of-way. (12) Typical details of manholes and/or handholes owner plans to use or access. (13) Complete legend of drawings submitted by owner, which may be provided by reference to previously submitted documents acceptable to the city. (14) The construction methods to be employed for the protection of existing structures, fixtures, and facilities within or adjacent to the public right-of-way, and the dates and times work will occur, all of which (methods, dates, times, etc.) are subject to approval of the responsible person. (15) A description of standard barricading showing placement of barricades, cones and informational signs used on the project. In most cases, layouts will be similar to those shown in the latter part of the manual. Deviation from the manual will be allowed only with approval of the responsible person. The description will include a listing of all persons directly responsible for the safety on each project to include an address or a telephone listing at which such person can be reached at any hour of the day if a hazardous condition develops. This description shall be provided to the city a minimum of five business days prior to the start of construction. (16) Proof of insurance and bonds as required by the city. (17) Disclosure if the proposed facility is: a. In a residential area; or b. In an underground utility district or other area with undergrounding requirements. (18) A pre-permit survey completed, signed and sealed by a qualified and experienced professional engineer in accordance with the city's requirements, certifying that contractor's facilities can be installed on the identified structure in compliance with all applicable codes, regulations and laws. The professional engineer's qualifications must include experience performing work for similar attachments on similar facilities. (19) Detailed plans for each facility including representative drawings or pictures of the intended equipment and proposed dimensions of same. (20) Certification that the proposed facility complies with applicable regulations of the Federal Communications Commission and that the proposed facility shall not cause any interference with the city's public safety radio system, traffic light system, or other city safety communications components. (21) Certification that the proposed facility will be placed into active commercial service by or for the contractor not later than the 60 th day after the date the construction and final testing of the facility is completed. (22) If applicable, contractor shall have in place an executed license agreement with the city. a. The permit application will be denied if this license agreement is not in place at the time the application is submitted. b. Engineering and construction plans and drawings related to the facility, including where the proposed facility will be connected, shall also be provided. c. If the applicant is not the same as the licensee identified in the license agreement, the licensee shall sign the permit application or provide a letter of agency satisfactory to the city. The licensee in such license agreement shall be presumed to be the owner of the facility and related equipment, and shall be fully responsible for them and the fees payable to the city thereunder. (23) If the proposed location lies within a highway right-of-way, the contractor must provide evidence of a permit from the state or federal government. (24) Any other information deemed reasonably necessary by the responsible person. (c) The city's acceptance of the submitted design documents does not relieve the contractor and its engineer of full responsibility and liability for any errors and/or omissions in the engineering analysis. (d) The city shall review the permit application for completeness and notify the contractor in writing if the contractor needs to submit additional or missing information. Such written notice will be provided within 30 days after receipt of a permit application for a facility. The notice shall specifically identify the missing information. If the contractor does not submit the missing or additional information within 180 days of the notice, the contractor's permit application shall be deemed withdrawn. (e) The city shall review the permit application to determine if the requested location and proposed installation complies with all applicable codes. (1) If the city denies the permit application, it will notify the contractor by electronic mail on the date the city denies the application, stating the basis for the denial. (2) The contractor may cure the deficiencies identified by the city within 30 days by resubmitting the application, along with payment to the city for the city's actual costs incurred in reviewing the resubmitted application.

(Ord. No. 4406-08-2017, § 2(Exh. A), 8-12-17)

Ask a question about Lewisville law

Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.