For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16-113 — Definitions

Code of Ordinances of the City of Lewisville, Texas (Supp. No. 34: codified through Ordinance No. 0854-26-ORD, adopted July 6, 2026) · Lewisville City Code § 16-113

Corpus is an independent public-information project, not the official City of Lewisville website. Stable reference: corpuslaw.us/code/91018d5c-babe-4be1-a641-bc629254def8

Sec. 16-113. - Definitions.

As used in this article: Act: The Federal Water Pollution Control Act, also known as the Clean Water Act, as it now exists or as hereafter amended, (33 United States Code § 1251 et seq.). Amalgam process wastewater: means any wastewater generated and discharged by a dental discharger through the practice of dentistry that may contain dental amalgam. Amalgam separator: means a collection device designed to capture and remove dental amalgam from the amalgam process wastewater of a dental facility. Approval authority: The Texas Commission on Environmental Quality (TCEQ). Authorized official: A responsible corporate officer if the industrial user is a corporation, a general partner or proprietor if the industrial user is a partnership or sole proprietorship, respectively, a director or highest official appointed to oversee the operation and performance activities if the industrial user is a federal, state or local government or a representative of these individuals who is responsible for the overall operation of the facility or for environmental matters and being so, is authorized, in writing, to the control authority. Best management practices or BMPs: Schedules of activities, prohibitions of practices, maintenance procedures, and other management practices to implement the prohibitions listed in 40 CFR Sections 403.5(a)(1) and (b). BMPs also include treatment requirements, operating procedures, and practices to control plant site runoff, spillage or leaks, sludge or waste disposal, or drainage from raw materials storage. BOD: Biochemical oxygen demand defined as the quantity of oxygen by weight, expressed in mg/L, utilized in the biochemical oxidation of organic matter under standard laboratory conditions for five days at a temperature of 20 degrees Centigrade; Bypass: The intentional diversion of a wastestream from any portion of a user's treatment facility. Categorical industrial user: An industrial user subject to a categorical pretreatment standard or categorical standard. Categorical pretreatment standard or categorical standard: Any regulation containing pollutant discharge limits promulgated by EPA in accordance with sections 307(b) and (c) of the Clean Water Act (33 U.S.C. section 1317) that apply to a specific category of industrial users and that appear in 40 CFR Chapter I, Subchapter N, parts 405-471. Chemical oxygen demand or COD: The quantity of oxygen utilized in the chemical oxidation of organic matter under standard laboratory procedures, usually expressed as a concentration in mg/l. City: The City of Lewisville, Texas, or any authorized person acting in its behalf. Code of Federal Regulations or CFR: A codification of the general and permanent rules published in the federal register by the executive departments and agencies of the federal government. Composite sample: A sample that is collected over time, formed either by continuous sampling or by mixing discrete samples. The sample may be composited either as a time composite sample: composed of discrete sample aliquots collected in one container at constant time intervals providing representative samples irrespective of stream flow; or as a flow proportional composite sample: collected either as a constant sample volume at time intervals proportional to stream flow, or collected by increasing the volume of each aliquot as the flow increases while maintaining a constant time interval between the aliquots, or as defined by 40 CFR 403 Appendix E, as it now exists or as hereafter amended. Control authority or CA: The director of public services (or other official designated by the city manager) of the city, or his duly authorized agent or representative. Control point: A point of access to a course of discharge before the discharge mixes with other discharges in the public sewer, also known as an inspection port and/or control manhole. Daily maximum: The maximum allowable discharge of pollutant during a calendar day. Where daily maximum limitations are expressed in units of mass, the daily maximum is the total mass discharged over the course of the day. Where daily maximum limitations are expressed in terms of concentration, the daily maximum is the arithmetic average measurement of the pollutant concentration derived from all measurements taken that day. Dental amalgam: means an alloy of elemental mercury and other metal(s) that is used in the practice of dentistry. Dental discharger: means a facility where the practice of dentistry is performed, including, but not limited to, institutions, permanent or temporary offices, clinics, home offices, and facilities owned and operated by federal, state or local governments, that discharges wastewater to a publicly owned treatment works (POTW). Dental dischargers are regulated industrial users according to 40 CFR Part 441. Discharge: To deposit, conduct, drain, emit, throw, run, allow to seep, or otherwise release or dispose of, or to cause, allow, permit, or suffer any of these acts or omissions. Domestic sewage or wastewater: Water-borne waste normally discharged from the sanitary conveniences of dwellings (including apartments, houses and hotels), office buildings, factories and institutions, free from storm surface water and industrial waste. Environmental Protection Agency or EPA: The U.S. Environmental Protection Agency or, where appropriate, the regional water management division director, or other duly authorized official of said agency. Gallons per day or GPD: A measurement of flow rate. Grab sample: A sample which is taken from a wastestream without regard to the flow in the wastestream and over a period of time not to exceed fifteen (15 minutes), or as defined by 40 CFR 403 Appendix E, as it now exists or as hereafter amended. Hazardous waste: As defined by 40 CFR 261, as it now exists or as hereafter amended. Indirect discharge: The introduction of pollutants into the POTW from any non-domestic source within the jurisdiction of this article, [40 CFR 403.3(i), as it now exists or as hereafter amended]. Industrial user or user or IU: A source of indirect discharge, [40 CFR 403.3(j), as it now exists or as hereafter amended]. Industrial waste: Waste resulting from any process of industry, manufacturing, trade or business. Industrial waste surcharge: The charge assessed an industrial user for discharging into the city's sewer system, an industrial waste which is of greater strength than domestic sewage. Inspection port: See definition of Control point. Instantaneous maximum allowable discharge limit: The maximum concentration of a pollutant allowed to be discharged at any time, determined from the analysis of any discrete or composited sample collected, independent of the industrial flow rate and duration of the sampling event. Interceptor: A device designed and installed to separate and retain deleterious, hazardous or undesirable matter from normal wastewater and permit normal sewage or liquid waste to discharge into the disposal system by gravity. Interference: A discharge, which alone or in conjunction with a discharge or discharges from other sources, inhibits or disrupts the POTW, its treatment processes or operations or its sludge processes, use or disposal; and therefore, is a cause of a violation of the city's NPDES or TPDES permit, or of the prevention of sewage sludge use or disposal in compliance with any of the following statutory/regulatory provisions or permits issued there under, or any more stringent state or local regulations: Section 405 of the Clean Water Act; the Solid Waste Disposal Act, including Title II commonly referred to as the Resource Conservation and Recovery Act (RCRA); any state regulations contained in any state sludge management plan prepared pursuant to Subtitle D of the Solid Waste Disposal Act; the Clean Air Act; the Toxic Substances Control Act; and the Marine Protection, Research, and Sanctuaries Act; or as defined by 40 CFR 403.3(k), as it now exists or as hereafter amended. Medical waste: Isolation wastes, infectious agents, human blood and blood products, pathological wastes, sharps, body parts, contaminated bedding, surgical wastes, potentially contaminated laboratory wastes, and dialysis wastes. mg/L: Milligrams per liter as a weight-to-volume ratio, equivalent to parts per million. Monthly average limit: The highest allowable average of "daily discharges" over a calendar month, calculated as the sum of all "daily discharges" measured during a calendar month divided by the number of "daily discharges" measured during that month. National categorical standard orpretreatment standard: Any regulations containing pollutant discharge limits promulgated by the approval authority in accordance with Sections 307(b) and (c) of the Clean Water Act, that apply to a specific category of industrial user. This term includes prohibitive discharge limits established pursuant to 40 CFR 403.5. in accordance with 40 CFR 403.3(l), as it now exists or as hereafter amended. New source: (1) Any building, structure, facility, or installation from which there is (or may be) a discharge of pollutants, the construction of which commenced after the publication of proposed pretreatment standards under Section 307(c) of the Act which will be applicable to such source if such standards are thereafter promulgated in accordance with that section, provided that: a. The building, structure, facility, or installation is constructed at a site at which no other source is located; or b. The building, structure, facility, or installation totally replaces the process or production equipment that causes the discharge of pollutants at an existing source; or c. The production or wastewater generating processes of the building, structure, facility, or installation is substantially independent of an existing source at the same site. In determining whether these are substantially independent, factors such as the extent to which the new facility is integrated with the existing plant, and the extent to which the new facility is engaged in the same general type of activity as the existing source, should be considered. (2) Construction on a site at which an existing source is located results in a modification rather than a new source if the construction does not create a new building, structure, facility, or installation meeting the criteria of sections (1)b or (1)c above, but otherwise alters, replaces, or adds to existing process or production equipment. (3) Construction of a new source as defined under this paragraph has commenced if the owner or operator has: a. Begun, or caused to begin, as part of a continuous on-site construction program: 1. Any placement, assembly, or installation of facilities or equipment; or 2. Significant site preparation work including clearing, excavation, or removal of existing buildings, structures, or facilities which is necessary for the placement, assembly, or installation of new source facilities or equipment; or b. Entered into a binding contractual obligation for the purchase of facilities or equipment, which are intended to be used in its operation within a reasonable time. Options to purchase or contracts which can be terminated or modified without substantial loss, and contracts for feasibility, engineering, and design studies do not constitute a contractual obligation under this paragraph; or as defined by 40 CFR 403.3(m), as it now exists or as hereafter amended. Non-contact cooling water: Water used for cooling which does not come into direct contact with any raw material, intermediate product, waste product, or finished product. Normal domestic sewage: Normal sewage for the city in which the concentration of total suspended solids and five-day 20° C biochemical oxygen demand (BOD) is established at 240 milligrams per liter, by weight, on the basis of the normal daily concentration of 0.20 pounds per capita, per 100 gallons. NPDES permit: The National Pollutant Discharge Elimination System permit issued to the POTW pursuant to Section 402 of the Clean Water Act. Pass through: A discharge which exits the POTW into waters of the United States in quantities or concentrations which, alone or in conjunction with a discharge or discharges from other sources, is a cause of a violation of any requirements of the city's NPDES permit, including an increase in the magnitude or duration of a violation; or as defined by 40 CFR 403.3(p), as it now exists or as hereafter amended. Person: Any individual, partnership, co-partnership, firm, company, corporation, association, joint stock company, trusts, estate, governmental entity, or any other legal entity; or their legal representatives, agents, or assigns. This definition includes all federal, state, and local governmental entities. pH: The logarithm (Base 10) of the reciprocal of the hydrogen ion concentration (the negative log of the hydrogen ion). Pollutant: Dredge spoil, solid waste, incinerator residue, filter backwash, sewage, garbage, sewage sludge, munitions, medical wastes, chemical wastes, biological materials, radioactive materials, heat, wrecked or discarded equipment, rock, sand, cellar dirt, municipal, agricultural and industrial wastes, and concentration characteristics of certain wastewater. Pollution: A condition created by the presence of harmful or objectionable material, pollutants. Pretreatment: The reduction of the amount of pollutants, the elimination of pollutants, or the alteration of the nature of pollutant properties in wastewater prior to, or in lieu of, introducing such pollutants into the POTW. This reduction or alteration can be obtained by physical, chemical, or biological processes; by process changes; or by other means, except by diluting the concentration of the pollutants unless allowed by an applicable pretreatment standard, or as defined by 40 CFR 403.3(s), as it now exists or as hereafter amended. Pretreatment requirements: Any substantive or procedural requirement related to pretreatment imposed on a user, other than a pretreatment standard, or as defined by 40 CFR 403.3(r), as it now exists or as hereafter amended. Pretreatment standards: Any regulation containing pollutant discharge limits including, but not limited to, national pretreatment standards, categorical pretreatment standards, prohibited discharge limits and local discharge limits. Process wastewater: Any water which, during manufacturing or processing, comes into direct contact with or results from the production or use of any raw material, intermediate product, finished product, by-product, or waste product. Prohibited discharge standards or prohibited discharges: Absolute prohibitions against the discharge of certain substances; these prohibitions appear in subsection 16-114(a) of this article. Publicly owned treatment works or POTW: The city's publicly owned treatment works including any devices and systems used in storage, treatment, recycling and reclamation of municipal sewage or industrial waste of a liquid nature. This definition also includes sewers, pipes and other conveyances only if they convey wastewater to the POTW treatment plant. The term also includes the city which has jurisdiction over the discharges to and the discharges from such treatment works. Resource Conservation and Recovery Act or RCRA: Statutory provisions and regulations as provided in Title II of the Solid Waste Disposal Act (SWDA). Sanitary sewer: A public sewer that conveys domestic wastewater or industrial wastewater or a combination of both, and into which stormwater, surface water, ground water, and other polluted wastes are not intentionally passed. Shall: Wherever used in this article will be interpreted in its mandatory sense; "may" is permissive. Significant industrial user or SIU: (1) A user subject to categorical pretreatment standards; or (2) A user that: a. Discharges an average of 25,000 gpd or more of process wastewater to the POTW (excluding sanitary, non-contact cooling, and boiler blowdown wastewater); b. Contributes a process wastestream which makes up five percent or more of the average dry weather hydraulic or organic capacity of the POTW treatment plant; or c. Is designated as such by the control authority on the basis that it has a reasonable potential for adversely affecting the POTW's operation or for violating any pretreatment standard or requirement. (3) Upon a finding that a user meeting the criteria in subsection (2) above has no reasonable potential for adversely affecting the POTW's operation or for violating any pretreatment standard or requirement, the control authority may at any time, on its own initiative or in response to a petition received from a user, and in accordance with procedures in 40 CFR 403.8(f)(6), determine that such user should not be considered a significant industrial user; or as defined by 40 CFR 403.3(v), as it now exists or as hereafter amended. Significant noncompliance or SNC: As defined by 40 CFR 403.8(f)(2)(viii)(A-H), as it now exists or as hereafter amended, which includes: (1) Chronic violations of wastewater discharge limits, defined here as those in which 66 percent or more of all measurements taken for the same pollutant parameter during a six-month period exceed (by any magnitude) a numeric pretreatment standard or requirement, including instantaneous limits, as defined by 40 CFR 403.3(I); (2) Technical review criteria (TRC) violations, defined here as those in which 33 percent or more of all of the measurements taken for the same pollutant parameter during a six-month period equal or exceed the product of the numeric pretreatment standard or requirement including instantaneous limits, as defined by 40 CFR 403.3(I) multiplied by the applicable TRC (TRC = 1.4 for BOD, TSS, fats, oil, and grease, and 1.2 for all other pollutants except pH); (3) Any other violation of a pretreatment standard or requirement as defined by 40 CFR 403.3(I) (daily maximum, long-term average, instantaneous limit, or narrative standard) that the POTW determines has caused, alone or in combination with other discharges, interference or pass through (including endangering the health of POTW personnel or the general public); (4) Any discharge of a pollutant that has caused imminent endangerment to human health, welfare or to the environment or has resulted in the POTW's exercise of its emergency authority under paragraph (f)(1)(vi)(B) of 40 CFR 403.8 to halt or prevent such a discharge; (5) Failure to meet, within 90 days after the schedule date, a compliance schedule milestone contained in a local control mechanism or enforcement order for starting construction, completing construction, or attaining final compliance; (6) Failure to provide, within 45 days after the due date, required reports such as baseline monitoring reports, 90-day compliance reports, periodic self-monitoring reports, and reports on compliance with compliance schedules; (7) Failure to accurately report noncompliance; or (8) Any other violation or group of violations, which may include a violation of best management practices, which the POTW determines will adversely affect the operation of the local pretreatment program. Slug: Any discharge of a non-routine, episodic nature, including but not limited to, an accidental spill or non-customary batch discharge, or pollutant which may include oxygen demanding pollutants (BOD, etc.) released at a flow rate and/or pollutant concentration which may cause an interference to the POTW, pass-through to the receiving stream, sludge contamination or endangerment to the POTW personnel, or in any other way violate the control authority's regulations, local limits, or permit conditions, as defined in 40 CFR Part 403.8(f)(2)(vi). Standard industrial classification (SIC) code: As defined by the U.S. Department of Commerce Bureau of the Census and further defined in the Standard Industrial Classification Manual issued by the United States Office of Management and Budget. Storm sewer: A public sewer which carries stormwater, surface water and drainage, into which domestic wastewater or industrial wastes are not intentionally passed. Stormwater: Any flow occurring during or following any form of natural precipitation, and resulting from such precipitation, including snowmelt. TCEQ: The Texas Commission on Environmental Quality, any duly authorized official of said agency, or any successor agency. Total suspended solids or TSS: Solids measured in mg/L that float on the surface or, are in suspension in water, wastewater, or other liquids, and which are removable by a laboratory filtration device. TPDES: The Texas Pollutant Discharge Elimination System, or the state regulatory authority to administer the NPDES program and requirements of certain sections of the federal Clean Water Act. Unpolluted wastewater: Stormwater, unpolluted groundwater, roof runoff, downspouts, yard fountains, pools, cooling water, drainage, or water which does not contain pollutants. USC: The United States Code. USEPA: The United States Environmental Protection Agency. Wastewater: A combination of the liquid and water-carried wastes from residential dwellings, commercial buildings, industrial and manufacturing facilities, and institutions, whether treated or untreated, which are contributed to the POTW. Wastewater service charge: The charge on all users of the public sewer system whose wastes do not exceed in strength the concentration values established as representative of normal wastewater. Watercourse: A natural or man-made channel in which a flow of water occurs, either continuously or intermittently.

(Ord. No. 3734-01-2010, § I, 1-4-10; 0220-20-ORD, § 1(Exh. A), 6-1-20)

Ask a question about Lewisville law

Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.