§ 4-132 — Same—Amendments

Code of Ordinances of the City of Lewisville, Texas (Supp. No. 34: codified through Ordinance No. 0854-26-ORD, adopted July 6, 2026) · Lewisville City Code § 4-132

Corpus is an independent public-information project, not the official City of Lewisville website. Stable reference: corpuslaw.us/code/677f90e2-fbd5-4473-9090-00c3f20889c4

Sec. 4-132. - Same—Amendments.

The city adopts the following revisions and additions to the International Mechanical Code 2021 Edition. Section 101.1; amend to read as follows: 101.1 Title. These regulations shall be known as the Mechanical Code of the City of Lewisville, hereinafter referred to as "this code." Section 102.8; amend to read as follows: 102.8 Referenced codes and standards. The codes and standards referenced herein shall be those that are listed in Chapter 15 and such codes, when specifically adopted, and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between provisions of this code and the referenced standards, the provisions of this code shall apply. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the adopted amendments. Any reference to NFPA 70 or the National Electrical Code (NEC) shall mean the Electrical Code as adopted. Section 103; amend title to read as follows: SECTION 103 DEPARTMENT OF NEIGHBORHOOD AND INSPECTION SERVICES Section 103.1; amend to read as follows: 103.1 General. The Department of Neighborhood & Inspection Services is hereby created and the official in charge thereof shall be known as the code official. The function of the agency shall be the implementation, administration and enforcement of this code. Section 104.8; delete. Section 104.8.1; delete. Section 109.2; amend to read as follows: 109.2 Fee schedule. The fee for each permit shall be as set forth in the city ordinance 2-201 providing for permit, inspection, and license fees. Section 109.4; amend to read as follows: 109.4 Work commencing before permit issuance. Any person who commences work on a mechanical system before obtaining the necessary permits shall be subject to an investigation fee, in addition to the permit fee. The investigation fee shall be equal to the amount of the permit fee as set forth in city ordinance 2-201. The payment of such investigation fee shall not exempt the applicant from compliance with all other provisions of either this code or the technical codes nor from penalty prescribed by law. Section 113.1; amend to read as follows: 113.1 General. An applicant may appeal any order, decision, or determination made by the code official relative to the application and interpretation of this code. In order to hear and decide appeals of orders, decisions, or determinations made by the code official relative to the application and interpretation of this code, the City Council shall act as the Board of Appeals. An appeal must be filed in writing with the City Manager within thirty (30) days after the date of the order, decision, or determination. After receiving an appeal in accordance with this section, the City Manager shall submit the appeal to the City Council for their consideration. The City Council's decision on the appeal shall be the final decision. Section 113.3; delete. Section 113.4; delete. Section 114; delete in its entirety. Section 115.2; amend and add exception to read as follows: 115.2 Notice of violation. The code official is authorized to serve a notice of violation or order on the person responsible for the erection, installation, alteration, extension, repair, removal or demolition of mechanical work in violation of the provisions of this code, or in violation of a detail statement or the approved construction documents thereunder, or in violation of a permit or certificate issued under the provisions of this code. Such order shall direct the discontinuance of the illegal action or condition and the abatement of the violation. Exception: Citations for violations of this code may be issued without requiring the issuance of a notice. Section 115.3; amend to read as follows: 115.3 Prosecution of violation. If a notice of violation is issued and is not complied with in the time prescribed by such notice, the code official is authorized to request the legal counsel of the jurisdiction to institute the appropriate proceedings at law or in equity to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the structure in violation of the provisions of this code or of the order or direction made pursuant hereto. Section 115.4; amend to read as follows: 115.4 Violation penalties. Persons who violate a provision of this code or fail to comply with any of the requirements thereof or who erect, install, alter or repair mechanical work in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, shall be subject to penalties as prescribed by Section 1-15 of the Code of Ordinances of the City of Lewisville. Each day that a violation continues shall be deemed a separate offense. Section 306.3; amend to read as follows: 306.3 Appliances in Attics. Attics containing appliances shall be provided . . . {bulk of paragraph unchanged} . . . side of the appliance. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by 762 mm), or larger where such dimensions are not large enough to allow removal of the largest appliance. A walkway to an appliance shall be rated as a floor as approved by the code official. As a minimum, for access to the attic space, provide one of the following: 1. A permanent stair. 2. A pull down stair with a minimum 300 lb. (136 kg) capacity. 3. An access door from an upper floor level. 4. Access panel may be used in lieu of items 1, 2, and 3 with prior approval of the code official due to building conditions. Exceptions: 1. The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening. 2. {Exception 2 unchanged.} 306.5 Equipment and Appliances on Roofs or Elevated Structures. Where equipment requiring access or appliances are located on an elevated structure or the roof of a building such that personnel will have to climb higher than 16 feet (4,877 mm) above grade to access such equipment or appliances, a permanent interior or exterior means of access shall be provided. Permanent exterior ladders providing roof access need not extend closer than 12 feet (2,438 mm) to the finish grade or floor level below and shall extend to the equipment and appliances' level service space. Such access shall . . . {bulk of section to read the same} . . . on roofs having a slope greater than 4 units vertical in 12 units horizontal (33-percent slope). ... {Remaining language unchanged}. Section 306.5.1; amend to read as follows: 306.5.1 Sloped Roofs. Where appliances, equipment, fans or other components that require service are installed on a roof having a slope of 3 units vertical in 12 units horizontal (25-percent slope) or greater and having an edge more than 30 inches (762 mm) above grade at such edge, a catwalk at least 16 inches in width with substantial cleats spaced not more than 16 inches apart shall be provided from the roof access to a level platform at the appliance. The level platform shall be provided on each side of the appliance to which access is required for service, repair or maintenance. The platform shall be not less than 30 inches (762 mm) in any dimension and shall be provided with guards. The guards shall extend not less than 42 inches (1,067 mm) above the platform, shall be constructed so as to prevent the passage of a 21-inch-diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the International Building Code. Access shall not require walking on roofs having a slope greater than 4 units vertical in 12 units horizontal (33-percent slope). Where access involves obstructions greater than 30 inches (762 mm) in height, such obstructions shall be provided with ladders installed in accordance with Section 306.5 or stairways installed in accordance with the requirements specified in the International Building Code in the path of travel to and from appliances, fans or equipment requiring service. Section 501.3; add a new exception 4 to read as follows: 4. Toilet room exhaust ducts may terminate in a warehouse or shop area when infiltration of outside air is present.

Section 306.5; amend to read as follows: (Code 1990, § 3-12-2; Ord. No. 1673-2-92, § II, 2-3-92; Ord. No. 2010-3-95, § II, 3-6-95; Ord. No. 2756-12-2001, § II, 12-10-01; Ord. No. 3265-10-2005, § I, 10-17-05; Ord. No. 3520-12-2007, § I, 12-17-07; Ord. No. 4039-12-2013, § 2, 12-16-13; Ord. No. 4271-05-2016, § 2, 5-2-16; 0241-20-ORD, § 2, 8-17-20; 0616-23-ORD, § 2, 11-6-23)

Ask a question about Lewisville law

Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.