Sec. 4-395. - Working specifications.
(a) Alarm system activation and deactivation panels may be of a key or keyless configuration. They must be installed on the interior of the structure. The system shall provide for variable entrance and exit grace times which shall be incorporated into the unit. (b) No alarm system shall be so designed as to generate an alarm due to the premises or a particular area of the premises not being secured at the time of attempted arming. The alarm system shall utilize an internal audible alert signal to notify the user that he has programmed grace period in which to deactivate the alarm system upon the user's entrance. In case of power failure, all alarm circuits shall automatically convert to stand-by battery supply, capable of supplying at least 12 hours of emergency power. (1) Installers of alarm systems shall make the user aware that a permit must be obtained from the city and shall comply with all requirements as set forth in state law. (2) The installer shall also instruct the user regarding the operation of the system, including but not limited to, the criteria for use of the police alert button device, stressing it is for the summoning of police only in the event of a real or immediate threat to life. (3) The installer shall not install an alarm system contrary to the provisions of this article. Alarm systems that are installed that are contrary to the provisions of this article are in violation of this article and the installer is subject to the punishment phase of this article for the day the alarm system is installed and each day or portion of a day thereafter are separate offenses until the alarm system adheres to the provisions of this article. (4) Any keyless configuration activating or deactivating device which contains only a single button to activate a police alert alarm shall provide for a design of such equipment that accidental activation will not occur and that activation is a deliberate act. (5) Alarm systems shall include a delay which will be so engineered so as an alarm will not be sent due to momentary breaks in electrical current caused by lightning. (6) All electrical equipment used for the installation of alarm systems shall be Underwriters' Laboratories, Inc., approved.
(Code 1990, § 3-10-13; Ord. No. 3270-10-2005, § 7, 10-17-05)
Ask a question about Lewisville law
Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.