(a) Floors. In food preparation areas, bars, storage areas, dish washing areas, restrooms and dressing rooms, floors shall be constructed of smooth, durable, easily cleanable, non-absorbent materials of commercial grade. Flooring must be light colored, without texture or patterns that create difficult places to clean. Floors that are water-flushed or that receive discharges of liquid shall be constructed of sealed concrete, terrazzo, ceramic quarry tile, or similar material that is graded to a properly installed, trapped floor drain. Floors of food service areas of day care centers, food storage, food display, and retail display areas shall be of non-absorbent materials designed to be easy to clean. (1) Prohibited floor covering. The use of cardboard, sawdust, wood shavings or non-sealed wooden floor, or similar materials as a floor covering is prohibited in food preparation areas. Carpet shall be prohibited in food service areas and retail food areas. (2) Floor sinks. Floor sinks are required under all indirectly plumbed sinks. (3) Mats and duckboards. Mats shall be of non-absorbent, grease resistant materials and of such size, design and construction as to facilitate their being easily cleaned. (4) Floor junctures. The juncture between walls and floors shall not present an open seam of more than 1/32 -inch. The floor/wall junctures of all floors must have coving, baseboard or sealant. (5) Utility line installation. Exposed utility service lines shall be installed in a way that does not obstruct or prevent cleaning of the floor. In all new or extensively remodeled establishments, installation of exposed horizontal utility lines on the floor is prohibited. (b) Walls/ceilings. In food preparation, bars, storage areas, dish washing areas and restrooms, walls and ceilings must be smooth, non-textured, easily cleanable, non-absorbent, light in color and durable. Exposed joists, rafters, or pipes are not permitted. Wall areas behind sinks or places that receive heavy use must be finished with fiber reinforced plastic (FRP), ceramic tile, or similar material to withstand moisture. In heavy food prep areas, walls behind stoves, grills or fryers shall be of stainless steel materials all the way to the floor. Bathroom walls shall be finished with similar material as those walls located behind food prep sinks. (c) Lighting. (1) Artificial lighting must be at least 50 foot candles over food preparation and dish washing areas, and positioned so that light is directly above sinks and food preparation areas. The walk in refrigeration units must have 50 candles. All other areas of the kitchen must have 30 foot candles, and 20 foot candles in storage rooms, restrooms and dining areas. (2) Shields are required on light fixtures in all food preparation, food storage, dish washing areas, inside refrigeration units and in vent-a-hoods. If using plastic sleeve type shields, they must have tight-fitting end caps. (d) Ventilation. All rooms shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke and fumes. Ventilation systems shall be installed and operated according to the current building code. When vented to the outside it cannot create an unsightly, harmful or unlawful discharge. Intake and exhaust air ducts shall be maintained to prevent the entrance of dust, dirt and other contaminating materials. Ventilation hoods are required for any cooking, baking, grilling and frying areas, and in areas above dishwashers to vent steam. (e) Building and utility inlets. Conduit and ductwork shall be kept to an absolute minimum and shall be installed in such a way as not to obstruct cleaning of walls, floors or ceilings. No pipes are to run along the floor. (f) Ice machines. Ice machines shall be of adequate size and located in areas that meet wall, floor and ceiling design standards for food preparation areas. Drain lines to ice machines are required to be plumbed to a floor drain with an approved air gap on the drain line. The ice machine cannot be located near sources of potential contamination such as exposed sewer lines. (g) Aisles and working spaces. Aisles and working spaces shall be unobstructed and of sufficient width to permit employees to perform their duties readily without contaminating food or food contact surfaces by clothing or personal contact. (h) Sneeze guards. Sneeze guards are required for all buffet and salad bars and shall have an average height of four feet six inches to five feet from the floor. Clean plates shall be made available and required of patrons for return trips to food bars. A sign to this effect shall be posted at salad bars and buffet tables. (i) Storage areas. (1) Food supplies and all food must be stored at least six inches above the floor with the exception of soda canisters or other impervious containers. Wood shelving is allowed in dry storage areas if it is light in paint color and finished with varnish or high gloss so that it is smooth, non-absorbent and easy to clean. (2) Contact type or other shelf paper is prohibited. The use of rubber webbing type covering is allowed under glasses to prevent chips on glassware. (3) Walls and ceilings in dry storage areas shall be finished with a light FRP color, or high gloss, enamel type paint that is light in color. Walls and ceilings in these areas must be smooth, non-textured, easily cleanable, non-absorbent, light in color, and durable. (j) Personal belongings/personal hygiene. Personal belongings must be kept in a designated storage place separate from food and food supplies. If lockers are used they are to be kept clean and in good repair. Employees may have beverages in the kitchen only if the cup is a tight-fitting, non-spillable container to preclude hand to mouth contamination. (k) Toxic chemical storage. Pesticides, cleaning supplies and other chemicals used in the operation of the establishment must be stored separately from any food, food supplies, single-service items and be stored separately from each other. All chemicals must be properly labeled with the name of the chemical contents, including all spray bottles. (l) Toilet facilities. Establishments that have areas for dining are required to provide restroom facilities for the general public. Public access cannot be through food preparation or storage areas. The handicap requirements must comply with the current building code. Walls, floors and ceilings are to be constructed as in food preparation areas to be durable, non-absorbent, light in color and easily cleanable. Self-closing doors and covered waste receptacles are required in the women's room and in the men's room if a diaper deck is installed. Toilet seats are to be of the open front design and kept in good repair. Knee pedals, electronic eye and metered faucets are allowable in public restrooms. (m) Sinks. (1) A three compartment sink is required for manual washing, rinsing and sanitizing of all pans, dishes, tableware and utensils. All sinks must be provided with hot and cold running water by means of a combination, mixing-valve type faucet. Water temperature for hand washing shall be 110°F. The sinks must be large and deep enough to completely submerge everything that is washed. Two self-draining boards (one on each side of the sink) must be available to allow dishes to air dry. An open grate shelf that is drainable, durable and non-absorbent will be allowed above sinks. (2) A separate utility sink or curbed cleaning facility with a floor drain is required for cleaning mops, brooms, and proper disposal of waste water. A rack to hang the mops and brooms off the floor and a mounted hose bracket to hang utility hoses are required. (3) A separate hand wash sink is required in food preparation and in dish washing areas. This is in addition to the hand wash sinks in restrooms. A hand sink shall be located within every 25 linear feet of unobstructed space in food preparation and dish washing areas so that it is convenient for employees to wash hands as often as necessary. If the sink is too close to other equipment, a splashguard is required. Sinks are to be of adequate size to allow for the thorough washing of hands and forearms. A sign shall be posted requiring employees to wash their hands before returning to work. Knee pedal type faucets, electronic eye faucets, and metered faucets are not allowed in food preparation areas. A supply of liquid soap, paper towels, hand sanitizer and a waste receptacle must be located at each hand sink. At the discretion of the regulatory authority, additional sinks such as pot sinks, dump sinks, fill sinks, utility wash sinks and food preparation sinks may be required. (n) Dishwashing machines. If an automatic dishwasher is used, it must properly wash, rinse and sanitize dishes. Chemical test papers or accurate, numerically-scaled thermometers/gauges to check the strength of the sanitizer or water temperature must be available. Dishwashing machines meant to sanitize by heat must be in accordance with the manufacturer's directions. A commercial dishwasher is required if the food establishment serves the public on dishware such as plates, glassware or reusable plastics. (o) Equipment and utensils. Equipment and utensils shall be designed and fabricated for durability under conditions of normal use and must be resistant to denting, bucking, pitting and chipping. All equipment shall be NSF-approved or equivalent and/or approved by the regulatory authority. (p) Food contact surfaces. Food contact surfaces must be durable, non-absorbent, easily cleanable, free of cracks, crevices, or seams and impervious to liquids. (q) Non-food contact surfaces. Non-food contact surfaces must be easily cleanable and constructed of such materials to be kept in good repair. (r) Floor mounted equipment. Floor mounted equipment must be six inches in height or sealed to the floor. Space must be provided between walls and fixtures to permit easy access for cleaning. (s) Refrigerators/freezers. Refrigerators/freezers must be commercial grade or NSF-approved, and each unit must have a visible and accurate, numerically-scaled thermometer. Walk-in refrigeration units must be commercially built and have interiors of impervious, non-absorbent materials. Wood and marlite surfaces in walk-in refrigeration units are not allowed. Shelves must be resistant to rust. (t) Outer openings. Outer doors must be self-closing to prevent entrance of insects/rodents and be effectively screened and tight fitting. Screening must not be larger than 16 mesh to one inch. (u) Paved areas. Paved areas must be smooth, non-absorbent, easily cleanable, and graded to drain. Paved areas are required around establishment entrances, exits, garbage, and receptacle wash areas. (v) Compactor/garbage receptacles/dumpsters. Compactor/garbage receptacles/dumpsters must be of durable, non-absorbent materials that are easily cleanable and leak proof. Lids must be available for garbage receptacles. Dumpsters and compactor lids and side-doors must be kept closed when not in use. (w) Water heaters. Water heaters must be of adequate size to provide enough hot water on demand for all hand washing, dish washing and cleaning during operation. (x) Laundry facilities. Laundry facilities shall be utilized only for the washing and drying of items used in the operation of the establishment. The washer and dryer must be located where there is no exposed food, cleaning equipment, utensils and single-use service articles. (y) Outdoor smoker/grill unit in a food establishment. (1) Outdoor smoker/grill units are required to be in an enclosure of adequate size to allow for the free movement of personnel around equipment. (2) The enclosure shall conform to all applicable city ordinances including building codes, fire codes, zoning regulations, etc. (3) The walls of the enclosure shall be constructed of solid material or screen material not to exceed 16 mesh to one inch. (4) The roof shall be constructed of a non-permeable material which is water resistant as well as fire resistant and shall be sloped to allow for proper drainage. (5) The floors shall be constructed of asphalt or cement which has been sealed so as to be non-absorbent and easily cleanable. (6) All outer openings shall be tightly sealed so as to prevent flies and other insects from entering the enclosure. (7) No food preparation is allowed in the enclosure.
(Ord. No. 3862-05-2011, § 1, 4-18-11)
Ask a question about Lewisville law
Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.