§ 22.04.215 — Sample collection
Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Code of Ordinances § 22.04.215
Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/53d69b2c-df4d-46fa-a4c7-d896148d5f47
§ 22.04.215: Sample collection.
(a) Except as indicated in subsection (b) and (c), below, the User must collect wastewater samples using 24-hour flow-proportional composite collection techniques, unless time-proportional composite sampling or grab sampling is authorized by the control authority. Where time proportional composite sampling or grab sampling is authorized by the control authority, the samples must be representative of the discharge. Using protocols (including appropriate preservation) specified in 40 CFR part 136 and appropriate EPA guidance, multiple grab samples collected during a 24-hour period may be composited prior to analysis as follows: for cyanide, total phenols, and sulfides the samples may be composited in the laboratory or in the field; for volatile organics and oil and grease, the samples may be composited in the laboratory. Composite samples for other parameters unaffected by the compositing procedures as documented in approved EPA methodologies may be authorized by the control authority, as appropriate. In addition, grab samples may be required to show compliance with instantaneous limits. [40 CFR 403.12(g)(3)] (b) Samples for oil and grease, temperature, pH, cyanide, phenols, sulfides, and volatile organic compounds must be obtained using grab collection techniques. (c) For sampling required in support of baseline monitoring and 90-day compliance reports required in [40 CFR 403.12(b) and (d)], a minimum of four (4) grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide and volatile organic compounds for facilities for which historical sampling data do not exist; for facilities for which historical sampling data are available, the control authority may authorize a lower minimum. For the reports required by subsections in (40 CFR 403.12(e) and 403.12(h)), the industrial user is required to collect the number of grab samples necessary to assess and assure compliance with applicable Pretreatment Standards and requirements. [40 CFR 403.12(g)(4)] (d) The decision to allow the alternative sampling (or site specific circumstances) must be documented in the IU file for that facility or facilities. (e) Samples should be taken immediately downstream from pretreatment facilities if such exist or immediately downstream from the regulated process if no pretreatment exists. Samples must be taken during the 24 hour period that discharge wastewater is flowing through the regulated process and/or pretreatment unit. (f) During parts of the day when there is no discharge of process wastewater, standing water should not be disproportionately sampled and analyzed as it would not be representative of the discharge from the facility. (g) Sampling protocols should take into consideration all of the operation conditions and the physical configuration of the industrial user facility and produce representative results. (h) Where there has been a change to existing facilities, for example, the addition of treatment, historic data that does not represent the current discharge would not be able to be used to justify a lower minimum of grab samples. (i) For sampling required on continued compliance and non-categorical SIU reports, the control authority shall require the number of grab samples necessary to assess and assure compliance by industrial users with applicable pretreatment standards and requirements. (j) Sampling requirements apply to BMR’s, 90-day reports, continued compliance and non-categorical SIU reports. (k) The control authority will be responsible for documenting site-specific circumstances and allowing alternate sampling in the industrial user permits. (l) Sampling and analysis techniques must yield analytical data that is representative of the discharge. The control authority will still need to document how alternate sampling techniques are representative of the discharge, and may require that more than four grab samples be taken and separately analyzed to ensure that sampling is representative. Where the control authority cannot verify that previous techniques were representative, such data will not support the use of this alternative practice. (m) The control authority will perform any required repeat sampling within 30 days of becoming aware of a violation, in cases where the control authority samples in lieu of the SIU. (n) The reports required herein must be based upon data obtained through appropriate sampling and analysis performed during the period covered by the report, which data are representative of conditions occurring during the reporting period. The control authority shall require that frequency of monitoring necessary to assess and assure compliance by industrial users with applicable pretreatment standards and requirements. Grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide, and volatile organic compounds. For all other pollutants, 24-hour composite samples must be obtained through flow-proportional composite sampling techniques, unless time-proportional composite sampling or grab sampling is authorized by the control authority. Where time-proportional composite sampling or grab sampling is authorized by the control authority, the samples must be representative of the discharge and the decision to allow the alternative sampling must be documented in the industrial user file for that facility or facilities. Using protocols (including appropriate preservation) specified in 40 CFR part 136 and appropriate EPA guidance, multiple grab samples collected during a 24-hour period may be composited prior to the analysis as follows: For cyanide, total phenols, and sulfides the samples may be composited in the laboratory or in the field; for volatile organics and oil & grease the samples may be composited in the laboratory. Composite samples for other parameters unaffected by the compositing procedures as documented in approved EPA methodologies may be authorized by the control authority, as appropriate.
( 1983 Code, sec. 28-132.2 ; Ordinance 2003-O0076 , sec. 14, adopted 7/24/2003 ; Ordinance 2020-O0150 , sec. 15, adopted 11/2/2020 )
Ask a question about Lubbock law
Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.