§ 28.16.005 — Amendments - Residential

Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Code of Ordinances § 28.16.005

Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/c75a6df9-c8c0-465d-8689-b90233ff710d

§ 28.16.005: Amendments - Residential.

(a) Above code programs. Section R102.1.1 is hereby amended to read as follows: R102.1.1 Above code programs. The code official or other authority having jurisdiction shall be permitted to deem a national, state or local energy-efficiency program to exceed the energy efficiency required by this code. Buildings approved in writing by such an energy-efficiency program shall be considered in compliance with this code. (b) Information on construction documents. Section R103.2 is hereby deleted in its entirety. (c) Interior design conditions. Section R302.1 is hereby deleted in its entirety. (d) Application. Section R401.2 is hereby amended to read as follows: R401.2 Application. Residential buildings shall comply with either Sections R401.2.1, R401.2.2, R401.2.3 or R401.2.4. Exception: Additions, alternations, repairs and changes of occupancy to existing buildings complying with Chapter 5. (e) Additional energy efficiency. Section R401.2.5 is hereby deleted in its entirety. (f) Maximum Assembly U-Factors and Fenestration Requirements. Table 402.1.2 is amended to read as follows: Table R402.1.2 Maximum Assembly U-Factorsa and Fenestration Requirements for Climate Zone 3 Fenestration U-Factor | 0.30 Skylight U-Factor | 0.55 Glazed Fenestration SHGCd | 0.25 Ceiling U-Factor | 0.026 Wood Frame Wall U-Factor | 0.084 Mass Wall U-Factorb | 0.098 Floor U-Factor | 0.047 Basement Wall U-Factor | 0.360 Crawl Space Wall U-Factor | 0.136 Notes: a. | Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source. b. | Mass walls shall be in accordance with Section R402.2.5. Where more than half the insulation is on the interior, the mass wall U-factors shall not exceed 0.12 in Climate Zone 3. c. | In Warm Humid locations as defined by Figure R301.1 and Table R301.1, the basement wall U-factor shall not exceed 0.360. d. | The SHGC column applies to all glazed fenestration. Exception: In Climate Zones 0 through 3, skylights shall be permitted to be excluded fenestration SHGC requirements provided that the SHGC for such skylights does not exceed 0.30. (g) Insulation Minimum R-Values and Fenestration Requirements by Component. Table R402.1.3 is hereby amended to read as follows: Table R402.1.3 Insulation Minimum R-Values and Fenestration Requirements by Componenta For Climate Zone 3 Fenestration U-Factorb,i | 0.30j Skylightb U-Factor | 0.55 Glazed Fenesration SHGCb,e | 0.25 Ceiling R-Value | 38 Wood Frame Wall R-Value | 13 Mass Wall R-Valuei | 8/13 Floor R-Value | 19 Basementc,g Wall R-Value | 0 Slabd R-Value & Depth | 0 Crawl Spacec Wall R-Value | 5ci or 13f Notes: a. | R-values are minimums. U-factors and SHGC are maximums. Where insulation is installed in a cavity that is less than the label or design thickness of the insulation R-value of the insulation shall be not less than the R-value specified in the table. b. | The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.In Climate Zones 0 through 3, skylights shall be permitted to be excluded from glazed fenestration SHGC requirements provided that the SHGC for such skylights does not exceed 0.30. c. | "5ci or 13"means R-5 continuous insulation (ci) on the interior or exterior surface of the wall or R-13 cavity insulation on the interior side of the wall. d. | R-5 insulation shall be provided under the full slab area of a heated slab in addition to the required slab edge insulation R-value for slabs as indicated in the table. The slab-edge insulation for heated slabs shall not be required to extend below the slab. e. | There are no SHGC requirements in the Marine Zone. f. | Basement wall instructions is not required in Warm Humid locations as defined by Figure R301.1 and Table R301.1 g. | The first value is cavity insulation; the second value is continuous insulation. h. | Mass walls shall be in accordance with Section R402.2.5. The second R-value applies where more than half of the insulation is on the interior of the mass wall. i. | A maximum U-factor of 0.32 shall apply in Climate Zones 3 through 8 to vertical fenestration products installed in buildings located either: 1. | Above 4,000 feet in elevation, or 2. | In windborne debris regions where protection of openings is required by Section R301.2.1.2 of the International Residential Code. j. | For impact rated fenestration complying with Section R301.2.1.2 of the International Residential Code or Section 1609.1.2 of the International Building Code, the maximum U-factor shall be 0.75 in Zone 2 and 0.65 in Zone 3. (h) Air leakage. Section R402.4 is hereby amended to read as follows: R402.4 Air leakage. The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.4. (i) Testing. Section R402.4.1.2 is hereby deleted in its entirety. (j) Rooms containing fuel-burning appliances. Section R402.4.4 is hereby deleted in its entirety. (k) Ducts located outside conditioned space. Section R403.3.1 on or before 7/1/2024 is hereby amended to read as follows: R403.3.1 Ducts located outside conditioned space. Supply and return ducts in attics shall be insulated to a minimum of R-6. Supply and return ducts in other portions of the building shall be insulated to a minimum of R-6. (l) Duct testing. Section R403.3.5 is hereby deleted in its entirety. (m) Duct leakage. Section R403.3.6 is hereby deleted in its entirety. (n) Circulation systems. Section R403.5.1.1 is hereby amended to read as follows: R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosyphon circulation systems shall be prohibited. Circulation pump shall be controlled by a seven-day time clock, aqua stat, or a combination of both devices. (o) Testing. Section R403.6.3 is hereby deleted in its entirety. (p) Covers. Section R403.10.3 is hereby deleted in its entirety. (q) Lighting equipment. Section R404.1 is hereby amended to read as follows: R404.1 Lighting equipment. Not less than 90 percent of the permanently installed lighting fixtures, excluding kitchen appliance lighting fixtures, shall contain only high-efficacy lighting sources. (r) Exterior lighting. Section R404.1.1 is hereby deleted in its entirety. (s) Interior lighting controls. Section R404.2 is hereby deleted in its entirety. (t) Exterior lighting controls. Section R404.3 is hereby deleted in its entirety. (u) Additional Efficiency Package Options. Section R408 is hereby deleted in its entirety.

( Ordinance 2020-O0019 adopted 2/11/2020 ; Ordinance 2024-O0031 adopted 3/26/2024 )

Ask a question about Lubbock law

Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.