§ 36.04.119 — Material to be used
Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Code of Ordinances § 36.04.119
Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/2b33ef9f-b40a-44b7-82a3-ea1b6735dd2c
§ 36.04.119: Material to be used.
Sidewalks, driveways, or inner curbs shall be constructed of concrete composed of Portland cement and fine aggregate, except as herein specified, except that other comparable material may be used when approved by the building official. The concrete shall contain not less than five (5) sacks of cement per cubic yard and not more than eight (8) gallons of water net per sack of cement when coarse aggregate is used. The amount of coarse aggregate shall not exceed eighty-five-one-hundredths (0.85) cubic foot per cubic foot of concrete (dry, loose volume). The minimum compressive strength at twenty-eight (28) days shall be three thousand (3,000) pounds per square inch.
( Ordinance 1466 , sec. 3, adopted 10/8/1953 ; 1959 Code, sec. 28-55 ; Ordinance 4371 , sec. 1, adopted 6/30/1964 ; 1983 Code, sec. 24-94 ; Ordinance 8568 , sec. 28, adopted 3/8/1984 )
Ask a question about Lubbock law
Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.