For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 39.02.024 — Specific allowances

Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Unified Development Code § 39.02.024

Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/88b3f60d-899b-46c8-b111-ed4934ba98bb

§ 39.02.024: Specific allowances.

a. Generally. The provisions of this Section set forth any special cases that warrant flexibility in the developmental standards in this UDC. b. Height requirements. 1. Exemptions. Unless otherwise expressly stated, the height regulations in this UDC do not apply to penthouse or roof structures for the housing of elevators, stairways, tanks, ventilating fans, or similar equipment required to operate and maintain the building, and fire or parapet walls, skylights, towers attached to a building, steeples, flagpoles attached to a building, chimneys, smokestacks, water tanks, silos, grain elevators, or similar structures. 2. Floor space calculation. No penthouse, roof structure, or any space above the height limit shall be allowed for the purpose of providing additional floor space. 3. Setback plane. As depicted in Figure 39.02.024-1, Setback Plane, the building height may be increased beyond the maximum permitted if the setbacks from all property lines (with the exception of the front lot line), which abut residentially zoned property, are increased one foot for each one foot of height above the maximum permitted height (Letter "C" in Figure 39.02.024-1). Figure 39.02.024-1Setback Plane [image] c. Yard requirements. The yard requirements in this UDC do not apply to the following projections into required yards: 1. Fire escapes, stairs, and balconies. Unenclosed fire escapes, stairways, and/or balconies, covered or uncovered, shall extend not more than four feet into the required front or rear yard. 2. Architectural features. Cornices, eaves, canopies, sunshades, gutters, chimneys, flues, belt courses, headers, sills, pilasters, lintels, ornamental features, box windows, or other similar architectural features that do not bear on the foundation shall project not more than two feet into any required yard. 3. Bay windows and chimneys. Within any residential district, bay windows (with a gross floor area of less than or equal to 12 square feet) shall extend not more than two feet into any required yard. 4. Garages. Front- and rear-loaded garages shall have a minimum setback of 20 feet, regardless of the required minimum setback for the remainder of the building being less than 20 feet. d. Infill compatibility. 1. Applicability. These infill compatibility standards shall apply to any new development or substantial renovation of an existing use that meets the following requirements: A. Not a part of a Planned Development District (PDD) under the previous Zoning Ordinance repealed on the effective date of this UDC; B. Meets the applicability standards of this Article; C. Is proposed on a lot that is located on a block face where more than 50 percent of the lots are occupied by an existing structure; and D. Is served by existing streets. 2. Contextual front building setbacks. A. Notwithstanding the minimum front setback requirements of Division 2.2, Zoning Districts and Standards. the applicant may use a contextual front setback when existing front setbacks differ from the front setback required by the base zoning district. In such circumstances, a contextual front setback may be at a point between the required front setback (as depicted with the letter "A" in Figure 39.02.024-2, Contextual Front Setback, below) and the front setback that exists on the closest developed lots that are adjacent (to the left and right of the subject property) and oriented to the same street as the subject lot (as depicted with the letter "B" in Figure 39.02.024-2). If the subject lot is a corner lot, then the setback may fall at a point between the required setback and front setback that exists on the lot that is adjacent and oriented to the same street as the subject lot. B. For example, if a zoning district requires a front setback of 20 feet, but the houses on either side of the infill lot have front setbacks of 10 and 20 feet, then the infill house shall have a front setback between 10 and 20 feet. Conversely, if a zoning district requires a front setback of 20 feet, but the houses on either side of the infilllot have a front setback of 20 and 40 feet, then the infill house shall have a front setback between 20 and 40 feet. C. The contextual front setback provisions shall not be used to reduce the setback of a residential garage which is 20 feet on a typical street frontage, including cul-de-sacs. Figure 39.02.024-2Contextual Front Setback [image] 3. Contextual rear setbacks. A. Notwithstanding the minimum rear setback requirements of Division 2.2, Zoning Districts and Standards. the applicant may apply a contextual rear setback to the primary structure, when existing rear setbacks differ from the rear setback required by the base zoning district. In such circumstances, a contextual rear setback may be at a point between the required rear setback and the rear setback that exists on the closest developed lots that are adjacent (to the left and right of the subject property) and oriented to the same alley right-of-way or rear facing lot or tract lines (where an alley right-of-way is not present) as the subject lot. B. For example, if a zoning district requires a rear setback of 20 feet for the primary structure, but the primary structures on either side of the infill lot have rear setbacks of 10 and 20 feet, then the infill house may have a rear setback between 10 and 20 feet. C. The contextual rear setback provisions shall not be used to reduce the required setback of a residential garage which is 20 feet from a typical right-of-way, access easement, or private drive that it fronts with an overhead door or similar oversized opening. 4. Appearance. Infill development shall be constructed to be generally compatible in appearance with other existing structures on the block that comply with this UDC. This provision shall be satisfied by constructing the proposed building(s) so that at least three of the following features are substantially similar to the majority of other buildings on the same and facing block: A. Roof pitch and overhang; B. Shape, size, and alignment of windows and doors; C. Front porches or porticos; D. Exterior building color; or E. Location and style of garage or carport. 5. Decision. Approval of a contextual setback(s) meeting the requirements of this Section shall be at the discretion of the Director of Planning. Refer to Section 39.07.039, Appeal of Administrative Decision. e. Lots. Regardless of the lot area or width, all lots in the SF-2 and MDR districts that existed prior to June 26, 1975, are deemed "conforming" with respect to lot area and lot width if they contain an existing, permanent, permitted residential dwelling. The lot width and area requirements of Section 39.02.004, Base Residential Districts, apply only in the event of a replatting of the property.

( Ordinance 2023-O0054 adopted 5/9/2023 ; Ordinance 2024-O0110 adopted 8/27/2024 ; Ordinance 2025-O0095 adopted 8/18/2025 )

Ask a question about Lubbock law

Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.