§ 39.03.010 — Off-street loading
Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Unified Development Code § 39.03.010
Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/a6da7013-5b44-49e0-9a1c-282bf6158784
§ 39.03.010: Off-street loading.
a. Loading facility required. An applicant shall provide an off-street loading facility as required by Table 39.03.002-1, Building and Site Design Applicability, or for an addition or enlargement of an existing use of more than 10,000 square feet that requires loading spaces. b. Loading standards. 1. Required spaces. An applicant shall provide a loading facility for each use in a building or on a site as prescribed in Table 39.03.009-2, Off-Street Parking and Loading Schedule, and according to the following floor area square footage requirements in Table 39.03.010-1, Required Off-Street Loading Facilities. Table 39.03.010-1Required Off-Street Loading Facilities Floor Area Square Footage | Minimum Number of Spaces 0–10,000 | 0 10,001–75,000 | 1 75,001–150,000 | 2 150,001–300,000 | 3 Over 300,000 | 1 for each 100,000 2. Common spaces. A. Multiple uses or occupancies located in a single building or on one site may be served by a common loading space if the Director of Planning determines that the loading space can adequately serve each use. B. For a common loading space, the Director of Planning, in making their determination, shall apply Table 39.03.009-2, Off-Street Parking and Loading Schedule, to the combination of buildings and uses served by the loading space instead of to each individual building and use. The schedule applicable to the use with the greatest load requirement applies. 3. Gross floor area. A. An off-street loading facility requirement is based on the gross floor area. The gross floor area does not include enclosed or covered areas used for off-street parking or loading. B. In this Section, each two square feet of exterior site area used for a commercial or industrial use equals one square foot enclosed floor area. 4. Dimensional requirements. A. The minimum dimensional requirements for loading facilities are 10 feet wide by 25 feet deep. B. A required loading facility shall maintain a 14-foot minimum vertical clearance. 5. Screening. Loading facilities are required at a 50-foot minimum distance from any residential property unless completely enclosed by building walls, or a uniformly solid wall, or any combination of the two, as depicted in Figure 39.03.010-1, Enclosed Loading. Loading facilities within 25 feet of the nearest point of any street intersection are prohibited. Figure 39.03.010-1Enclosed Loading [image]
( Ordinance 2023-O0054 adopted 5/9/2023 )
Ask a question about Lubbock law
Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.