For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8.07.033 — Application; filing fee; required information

Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Code of Ordinances § 8.07.033

Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/37df2919-b298-4a5f-96f7-7921aae807ac

§ 8.07.033: Application; filing fee; required information.

Each application shall be presented in the format most recently approved by the city council. Every application for a permit to drill and operate a well shall be in writing, signed by the applicant or by some person duly authorized to sign on his behalf, and it shall be filed with the city manager and be accompanied with a filing fee. The filing fee for the application shall be two thousand five hundred dollars ($2,500.00), until such time as the city council adjusts the fee in accordance with the provisions of section 1.03.004 of this code. A separate application must be filed by each applicant for each well to be drilled and operated. Each application shall include the following information in full: (1) The date of the application; (2) Name of the applicant; (3) Address of the applicant; (4) For the parcel of property where the well is drilled: (A) Proposed name of well; (B) Name and address of surface owner; (C) Name and address of mineral rights owner; (D) Name and address of mineral lease owner; and (E) Legal description of the site for the well (plat description or metes and bounds bearings). (5) Type and height of the pump jack or pump equipment proposed for producing the well; (6) Proposed depth of the well and name of the geologic formation as used by the RRC; (7) A legal description of the production unit. Any property recorded by plat should reference subdivision, block and lot numbers; (8) A true and correct copy of the plat survey filed with the RRC as part of the drilling permit application for the subject well; (9) An accurate map or drawing at a scale of 1/300 or greater to indicate the exact location of the proposed flow line(s) to storage facilities and shall indicate the exact location of such storage facilities on the map; (10) The following, including exact acreage and if within a plat approved by the planning and zoning commission, provide the subdivision name, block and lot number, and: (A) Ownership of surface acreage for each parcel in the production unit; (B) Ownership of mineral rights for each parcel in the production unit; (C) Ownership of surface acreage for each parcel abutting the production unit; (D) Ownership of mineral rights for each parcel abutting the production unit; (E) Name and address of each owner of any parcel of property within three hundred (300) feet of the proposed wellhead; and (F) Name and address of each owner of any parcel of property within one thousand (1,000) feet of the proposed storage facility. (11) Alternate location of the well due to adjacent land uses; (12) Air-pollution and odor-control devices; (13) Noise-control devices; (14) Type of engine for the pump equipment; (15) Height of the pump equipment during production; (16) Fire-control measures at the drill and pump site; (17) Fence or visual screening on the site of pump equipment and storage facilities; (18) Landscaping on the site of pump equipment and storage facilities; (19) Proof of contractual responsibilities of pump site and storage site maintenance; (20) Blowout prevention control; (21) Specific description of safety procedures required at the drill/pump site and the storage site; (22) Special handling/storage of sludge/waste from the drill site; (23) Special disposal of sludge/waste from the drill site; (24) Location of storage facilities; (25) Ingress/egress of vehicular traffic to the drill site and production site; (26) Specific precautions proposed to prevent contamination of the water aquifer at the drill site; (27) Specific proposal for source of water to be used during drilling operation; (28) Specific requirements for route and location of (buried or aboveground) flow lines between the wellhead and storage facilities; and (29) An emergency response plan establishing written procedures to minimize any hazard resulting from the drilling, completion, or producing of a well. Said plan shall use existing guidelines established by the RRC, the Texas Commission on Environmental Quality, the Texas Department of Transportation, the U.S. Department of Transportation, the Environmental Protection Agency, and/or the city fire code. This plan shall include a system of alarms to detect the loss of the well or any loss of containment integrity, access routes, and emergency contact information. A copy of the emergency response plan shall be kept on file with the city manager and on site. Said emergency response plan shall be updated annually.

( 1983 Code, sec. 14-143 ; Ordinance 8327 , sec. 2 (19A-5), adopted 5/28/1982 ; Ordinance 2015-O0021 adopted 3/12/2015 )

Ask a question about Lubbock law

Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.