For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4.3.4 — Multifamily, Mixed-Use, and Nonresidential Design

Code of Ordinances, City of McAllen, Texas (through Ord. 2026-83 adopted 2026-08-24) · McAllen Unified Development Code § 4.3.4

Corpus is an independent public-information project, not the official City of McAllen website. Stable reference: corpuslaw.us/code/4f370333-517d-41bb-a40b-9fd6e91fbbda

§ 4.3.4: Multifamily, Mixed-Use, and Nonresidential Design.

A. Building Design and Orientation. 1. All buildings shall be finished on all four sides with the same materials, detailing, and features and with a higher level of finish on the front facades (as set forth in the requirements below). The intent is not to limit materials but rather to ensure consistency in their use. 2. Any building visible from a public Right-of-Way shall either face such Right-of-Way or shall have a facade facing such Right-of-Way consistent with the character of the front facade. B. Required Design Element Options. The following is a list of design elements that, based upon the size of a building (see subsection C.3 below), must be incorporated into a building's design: 1. Canopies, awnings or porticos; 2. Overhangs; 3. Recesses or projections; 4. Arcades; 5. Peaked roof forms; 6. Arches; 7. Outdoor patios; 8. Display windows; 9. Architectural details (e.g., tile work or moldings integrated into the building facade); 10. Integrated planters or wing walls that incorporate landscape and sitting areas; 11. Offsets, reveals, or projecting ribs used to express architectural or structural bays. C. Minimum Use of Design Elements. A building's floor area shall determine the minimum number of required design elements implemented in its construction as set forth below: 1. A building square footage between 0 and 20,000 square feet shall have at least three (3) design elements listed in subsection B above. 2. A building square footage between 20,001 and 50,000 square feet shall have at least five (5) design elements listed in subsection B above, and shall be designed to appear as separate but attached buildings through the use of building material changes, wall plane/horizontal articulation, and roofline/vertical articulation. 3. A building square footage exceeding 50,000 square feet shall have at least seven (7) design elements listed in subsection B above, and shall be designed to appear as separate but attached buildings through the use of building material changes, wall plane/horizontal articulation, and roofline/vertical articulation. D. Front Facade Entry Requirements. 1. A front facade shall be articulated and designed to present a distinctive entry presence, emphasizing the building's entry point along the facade. 2. Entry design shall consist of at least three of the following design elements at the primary entrance, so that the primary entrance is architecturally prominent and clearly visible from the abutting street and parking: a. Architectural details such as arches, friezes, tile work, murals or moldings. b. Integral planters or wing walls that incorporate landscape or seating. c. Enhanced exterior light fixtures such as wall sconces, light covers with concealed light sources, ground-mounted accent lights, or decorative pedestal lights. d. Prominent three-dimensional features, such as belfries, chimneys, clock towers, domes, spires, steeples, towers or turrets. e. A repeating pattern of pilasters projecting from the facade wall by a minimum of eight inches or architectural or decorative columns. E. Pedestrian Shelter. Facades shall provide shelter integrated into building form alongside at least twenty-five percent (25%) of all building frontages adjacent to or facing the principal street or adjacent parking with a maximum shelter height of fifteen (15) feet. F. Building Articulation. Facade depth and height articulation shall be required on the front facade of a building, per the following: 1. Depth articulation of at least three (3) feet shall be required for every thirty (30) feet of building facade length. Depth articulation applies only below the roofline. 2. Height articulation for flat roofs of at least five (5) feet shall be required for every fifty (50) feet of building facade length. Pitched roofs do not require height articulation. G. Roof Design Standards. All structures shall be constructed with a pitched roof, flat roof (pitch less than or equal to 2:12) with a parapet, true mansard roof, or any combination thereof. 1. All flat roof surfaces shall be screened from ground level views so that such roof surfaces are not visible. 2. Roofs or stairwells and elevator machine rooms and other similar spaces shall be exempt from roofing design standards so long as they are not visible from ground level. For the purpose of this subsection, visible shall be defined as capable of being seen at a height of six (6) feet while standing at the highest grades on the property line. H. Windows. 1. Reflective glass shall not be permitted; glass shall not have solar reflectance that exceeds twenty percent (20%). 2. Glass shall have a character of transparency. Tinted glass may be used, however, the tinting shall not reduce the light transmission to less than thirty-five percent (35%). 3. Buildings shall provide glazing on a minimum of thirty-five percent (35%) of the ground floor front facade. 4. Side elevations shall contain a minimum of ten percent (10%) glazing of the ground floor side facade. 5. Windows shall be individually defined with detail elements such as frames, sills and lintels, and be placed to visually define the building stories. I. High-Quality Design Incentive. 1. Establishment of Scoring System and Associated Regulatory Incentives. a. Level 1 High-Quality Design. A cumulative score of sixty (60) points, as described below, shall result in the following changes to development regulations in Chapter 2 applicable to the subject property: (i) The granting of an additional ten (10) feet of maximum height. (ii) The granting of an additional ten percent (10%) of impervious cover. (iii) The granting of an additional ten percent (10%) of dwelling units per acre. b. Level 2 High-Quality Design. A cumulative score of eighty (80) points, as described below, shall result in the following changes to development regulations in Chapter 2 applicable to the subject property: (i) The granting of an additional twenty (20) feet of maximum height. (ii) The granting of an additional twenty percent (20%) of impervious cover. (iii) The granting of an additional twenty percent (20%) of dwelling units per acre. 2. High-Quality Design Actions and Associated Scoring Values. The following characteristics are determined to constitute evidence of high-quality design. The presence of each characteristic shall have an associated scoring value for the purposes of establishing whether a project achieves Level 1 or Level 2 High-Quality Design. a. Use of Building Materials Reflective of the City's Geographic Context. A project may receive a maximum of twenty (20) points for the use of building materials reflective of the City's geographic context, as follows: (i) Use of context materials on eighty-five percent (85%) of the exterior facade: Fifteen (15) points. (ii) Use of context materials on one hundred percent (100%) of the exterior facade: Twenty (20) points. b. Maintaining and Enhancing the Natural Environment. A project may receive a maximum of thirty (30) points for maintaining and enhancing the natural environment, as follows: (i) Altering the topography and elevation by no more than four (4) feet for at least eighty percent (80%) of the subject property, and preserving any natural channel or drainageway (including associated 100-year floodplain): Ten (10) points. (ii) Preserving at least thirty-five percent (35%) of the subject property unaltered in its natural state: Ten (10) points. (iii) Certification of at least fifty percent (50%) of the subject property as a certified Texas Wildscape, Monarch Waystation or similar third-party designation approved by the Planning Director as indicating consistency with City goals to encourage native and adaptive plants, discourage invasive and disease-prone plants, and support wildlife habitat: Ten (10) points. 3. Promotion of Conversation and Low-Impact Development Best Practices. A project may receive a maximum of thirty (30) points for development characteristics promoting conservation and low-impact development best practices, as follows: a. Incorporation of rainwater harvesting system capable of capturing a one (1) inch rainfall event for twenty-five percent (25%) of the roof area: Fifteen (15) points. b. Incorporation of Low Impact Development (LID) stormwater management practices subject to the approval of the Planning Director and City Engineer: Fifteen (15) points. c. Use of improved permeable surface for at least fifty percent (50%) of paved areas of driveways, parking and sidewalks (excluding the building footprint) with performance characteristics indicating at least fifty percent (50%) of water infiltrates through the surface and requiring minimal maintenance intervention, subject to the Planning Director and City Engineer approval: Fifteen (15) points. 4. Enhanced Building and Site Design Characteristics. A project may receive a maximum of 30 points for certain building design characteristics, as follows: a. Use of high-albedo roof materials to reduce height island effects, defined as use of roof products for at least seventy-five percent (75%) of the entire roof surface that reflect at least seventy-eight percent (78%) of sunlight (solar reflectivity index of 78) for roofs with a pitch less than or equal to 2:12 or twenty-nine percent (29%) of sunlight (solar reflectivity index of 29) for roofs with a pitch greater than 2:12: Ten (10) points. b. Use of a vegetative "green" roof to reduce heat island effects for at least fifty percent (50%) of the entire roof surface (this may also count toward credit for high-albedo roof materials if project is seeking points for both): Twenty (20) points. c. Placement of at least fifty percent (50%) of the parking to the side or rear of the main building: Ten (10) points. d. Increasing the glazing requirements for each facade by an additional twenty percent (20%): Ten (10) points. e. Use of at least five (5) of the following element options on the front and side facade: Fifteen (15) points for forty percent (40%) of the front and side facade, or twenty (20) points for sixty percent (60%) of the front and side facade. (i) Canopies, awnings or porticos; (ii) Overhangs; (iii) Recesses or projections; (iv) Arcades; (v) Peaked roof forms; (vi) Arches; (vii) Outdoor patios; (viii) Display windows; (ix) Architectural details (e.g., tile work or moldings integrated into the facade); (x) Integrated planters or wing walls that incorporate landscape and sitting areas; (xi) Offsets, reveals or projecting ribs used to express architectural or structural bays; (xii) Use of classic tripartite building design (e.g., a building design with a distinct base, middle and top similar to historic buildings found in small downtowns throughout Texas). J. Minor Modification. The Planning Director may approve elements not listed in this article if an equal or greater level of design and quality is provided. 1. Design Element Options. a. Alternatives to the design elements listed in subsection I.4.e above. b. Alternatives shall produce a similar or greater level of architectural design than the elements listed in subsection I.4.e above. 2. Building Articulation. Alternative articulation standards which differ from the requirements found in subsection I.4.e above may be approved. 3. Glazing Alternatives. Walls that must be blank for security or other requirements shall be enhanced by the use of plant materials, artwork, canopies, special lighting, or a combination of facade articulation and material changes.

( Ordinance 2026-16 adopted 2/9/2026 )

Ask a question about McAllen law

Corpus searches the McAllen sections it holds and shows the ones that match, with their citations. Free, no sign-in.