For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4.8.5 — Standards

Code of Ordinances, City of McAllen, Texas (through Ord. 2026-83 adopted 2026-08-24) · McAllen Unified Development Code § 4.8.5

Corpus is an independent public-information project, not the official City of McAllen website. Stable reference: corpuslaw.us/code/9ca95895-4d1d-48b2-be8e-a9c0261b1dd7

§ 4.8.5: Standards.

A. Generally. 1. The direct or reflected light from any light fixture shall not create a traffic hazard to operators of motor vehicles on public streets or to operators of aircraft, and no colored lights may be used in such a way as to be confused or construed as street-traffic or air traffic-control devices. 2. No blinking, flashing, or fluttering lights, or other illuminated device that has a changing light intensity, brightness, or color, is permitted in any zoning district. 3. The Building Official may require modifications to outdoor lighting after installation upon finding that the lighting, as installed, does not comply with these standards. Figure 4.8.5-1: Light Fixture Examples [image] B. Lighting Design. 1. All outdoor lighting shall meet the functional security needs of the proposed land use without adversely affecting surrounding properties and the natural environment. 2. All new and replacement light fixtures shall be full cutoff, except that light sources not exceeding five hundred (500) lumens for individual light fixtures, one hundred fifty (150) lumens for individual lights in a light string (e.g., patio lights), and three thousand (3,000) Kelvin in color temperature are not required to be full cutoff. For cutoff light fixtures, refer to Figure 4.8.5-1: Light Fixture Examples. 3. Light sources shall be concealed or shielded to minimize the potential for glare and light pollution. 4. Light fixtures shall be installed so that the luminaire angle is zero degrees (vertical to the ground). 5. Lights that shine outward and create direct glare are prohibited. 6. The amount of light trespass projected onto a residential use from another property shall not exceed 0.1 footcandles at the property line. 7. Lighting shall be distributed evenly to minimize extremes in luminance levels. 8. Light types of limited spectral emission, such as low-pressure sodium or mercury vapor lights, are prohibited in all areas. 9. Energy efficient lighting shall be used to the maximum extent practicable. 10. Light sources in residential zoning districts shall not exceed three thousand (3,000) Kelvin in color temperature. 11. Light sources in nonresidential zoning districts shall not exceed five thousand (5,000) Kelvin in color temperature. 12. Light fixtures used to illuminate flags, statues, or any other objects shall minimize glare beyond the illuminated object. C. Lighting Height. 1. Light fixtures mounted to a building or structure shall not exceed the height of the building or structure. 2. Freestanding light fixtures located in residential zoning districts shall be mounted no higher than twenty (20) feet from the ground. 3. Freestanding light fixtures located in other zoning districts shall be mounted no higher than thirty-five (35) feet from the ground. 4. Light fixtures higher than the maximum heights specified in this subsection, but not exceeding the maximum structure height in the applicable zoning district, are prohibited unless the Building Official finds that such lighting is appropriate and necessary for the development, shall not adversely affect surrounding properties and is consistent with the purpose of the lighting standards.

( Ordinance 2026-16 adopted 2/9/2026 )

Ask a question about McAllen law

Corpus searches the McAllen sections it holds and shows the ones that match, with their citations. Free, no sign-in.