For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4.9.7 — Sign Features

Code of Ordinances, City of McAllen, Texas (through Ord. 2026-83 adopted 2026-08-24) · McAllen Unified Development Code § 4.9.7

Corpus is an independent public-information project, not the official City of McAllen website. Stable reference: corpuslaw.us/code/bcebe0e2-9e6d-49fd-9499-f36a08317000

§ 4.9.7: Sign Features.

Signs may incorporate the following features established below; however, these features shall only be allowed as established in the tables in Section 4.9.8 through Section 4.9.12. A. Illumination. 1. Generally. a. A sign that is "illuminated" means any sign that incorporates illumination on or in the sign, or that directs illumination toward or over all or part of the sign, or that is created by the projection of illuminations onto a surface (such as a building wall). b. Permanent signs may be illuminated by static and continuous internal, external, and halo illumination configurations as indicated in the tables in Section 4.9.8 through Section 4.9.12. for each sign type. Figure 4.9.7-1: Sign Illumination Examples shows the various illumination configurations (from top left to bottom right: halo illumination, external illumination, external illumination, internal illumination). c. Temporary signs shall not be illuminated. Figure 4.9.7-1: Sign Illumination Examples [image] 2. Standards. The standards below apply to all signs that are illuminated. a. Signs that are illuminated shall not operate at brightness levels of more than 0.5 footcandles above ambient light conditions at the property line, as measured using a footcandle meter. Illumination levels shall be measured in footcandles with a meter sensor in a horizontal position at an approximate height of three (3) feet above grade. b. Illumination shall not include animation, moving video, or flashing, scrolling, intermittent, moving lights, rotating beams or flashing beacon lights. c. Signs that are illuminated shall not be illuminated by flashing, intermittent, or moving lights, or lights that consist of an image projected upon a stationary object. d. The illumination source for a sign or building shall be shielded from view from any point on the ground by either an opaque or translucent material. e. Illumination shall comply with all applicable provisions of the City's Electrical Code. f. Signs with illumination in or within one hundred (100) feet of a residential area shall be reduced to fifty percent (50%) of the maximum brightness level allowed by this section between the hours of 12:00 a.m. and 6:00 a.m. B. Electronic Message Centers. 1. Generally. a. A sign that incorporates an electronic message center (EMC) means a sign that displays a digital copy, including any illuminated sign on which the illumination is not kept stationary or constant in intensity and color when the sign is in use, including any light emitting diode (LED) or digital panel, and which varies in color or intensity (Figure 4.9.7-2 shows examples of signs that incorporate EMCs). b. Permanent signs may incorporate EMCs as indicated in the tables in Section 4.9.8 through Section 4.9.12 for each sign type. c. Temporary signs shall not incorporate EMCs. Figure 4.9.7-2: EMC Sign Examples [image] 2. Standards. a. Hold Time. (i) Each message on the sign must be displayed for at least fifteen (15) seconds duration. (ii) Message changes shall be completed instantaneously and shall be imperceptible. b. Electronic Copy. (i) Signs incorporating EMCs shall only contain static messages changed exclusively by dissolve or fade transitions, and shall not have movement or the appearance or optical illusion of movement during the static display period of any part of the sign. (ii) A static message shall not include any flashing or varying of light intensity, and the message shall not scroll. (iii) The change of message using dissolve or fade transition shall not exceed two (2) seconds of time between each message displayed on the sign. c. Brightness. (i) The intensity of the light source for an EMC shall not produce glare, the effect of which constitutes a traffic hazard or is otherwise detrimental to the public health, safety or welfare. (ii) An EMC shall not operate at brightness levels of more than 0.5 footcandles above ambient light conditions at the property line, as measured using a footcandle meter. Illumination levels shall be measured in footcandles with a meter sensor in a horizontal position at an approximate height of three (3) feet above grade. (iii) Prior to the issuance of a sign permit, the applicant shall provide written certification from the sign manufacturer that the light intensity has been factory pre-set not to exceed 0.5 footcandles above ambient light and that the intensity level is protected from end-user manipulation by password-protected software or other method as deemed appropriate by the Building Official. d. Light Sensing Device. Each digital sign must have a light-sensing device that shall adjust the brightness as ambient light conditions change. e. Technology. (i) The technology currently being deployed for EMCs is LED (light emitting diode), but there may be alternate, preferred, and superior technology available in the future. (ii) Any other technology that complies with the performance standards for EMCs, including the maximum brightness levels as stated in subsection 2.c above, is permitted. f. Automatic Shutoff. An EMC shall: (i) Have automatic dimmer software or solar sensors to control brightness for nighttime viewing and variations in daytime ambient light. (ii) Include systems and monitoring to either turn the display off, show "full black" on the display, or include a default mechanism that freezes the sign in one position if a malfunction occurs, and (iii) Be designed so that a catastrophic power surge shall cause the sign to go dark or to deploy the maximum brightness limitations, and (iv) Automatically adjust the intensity of its display according to natural ambient light conditions. 3. Maintenance. The light modules on EMCs shall be repaired or replaced if they become broken, burned-out, or substantially dimmed. C. Channel Letters. 1. Generally. a. Permanent signs may incorporate channel letters as indicated in the tables in Section 4.9.8 through Section 4.9.12. for each sign type (Figure 4.9.7-3: Channel Letter Examples shows examples of channel letters used as signs). b. Temporary signs shall not incorporate channel letters. Figure 4.9.7-3: Channel Letter Examples [image] 2. Standards. The standards below apply to signs incorporating channel letters. a. Where allowed, channel letters are limited to the required sign face area maximums. b. Channel letters may be illuminated if illumination is allowed for the sign type in that sign district. c. Channel letters shall affix flush against the wall of the building to which it is attached. d. Channel letters shall not extend more than sixteen (16) inches from the surface of the wall to which it is attached. e. Channel letters shall not project above the roofline of the building to which it is attached. D. Changeable Copy. 1. Generally. Permanent signs may incorporate changeable copy as indicated in the tables in Section 4.9.8 through Section 4.9.12. for each sign type (Figure 4.9.7-4: Changeable Copy Sign Examples shows examples of signs that incorporate changeable copies). Figure 4.9.7-4: Changeable Copy Sign Examples [image] 2. Standards. Changeable copies may be illuminated if the dimensions and standards allow illumination for the sign type in the district.

( Ordinance 2026-16 adopted 2/9/2026 )

Ask a question about McAllen law

Corpus searches the McAllen sections it holds and shows the ones that match, with their citations. Free, no sign-in.