§ 50-66 — International Fire Code adopted; amendments; copies on file
Code of Ordinances, City of McAllen, Texas (through Ord. 2026-83 adopted 2026-08-24) · McAllen Code of Ordinances § 50-66
Corpus is an independent public-information project, not the official City of McAllen website. Stable reference: corpuslaw.us/code/35cc7272-48d8-4454-a51a-96ed82ba76e1
§ 50-66: International Fire Code adopted; amendments; copies on file.
(a) There is hereby adopted for and by the city, the 2024 International Fire Code, with all appendices thereto, prepared by the International Code Council, except that: (1) Section 104.10 shall be amended by the addition of the following language at the end thereof: Such investigation shall be commenced within 24 hours, not including Sunday, of the occurrence of such fire. (2) Section 105.1 shall be amended to read as follows: Scope. Permits, and the requirements thereof, shall be in accordance with Section 105 unless the Fire Marshal determines otherwise by rule, all such rules being on file in the office of the city secretary and in the office of the fire marshal. (3) Section 113.3 shall be amended by the addition of the following language at the end thereof: Members of the Fire Prevention Division may issue citations or file complaints in Municipal Court as necessary for violations of the International Fire Code or this Article. Each violation shall be punishable by payment of a fine not to exceed $500.00 dollars. (4) Section 304.1.2 shall be amended by the addition of the following language at the end thereof: Accumulations of any type of waste or scrap material shall not be allowed to remain in any location where, in the opinion of the Fire Marshal, they may constitute a fire and life-safety hazard or impede Fire Department operations. (5) Section 401.5 shall be amended to read as follows: False Alarms and Reports. It shall be unlawful for a person, device or system to give, signal or transmit a false fire or medical alarm. (6) Section 503.1 shall be amended to read as follows: Where required. Fire lanes and other emergency access routes shall be provided in accordance with Sections 503.1.1 through 503.1.3, unless the Fire Marshal, in the exercise of reasonable discretion, determines otherwise. (7) Section 503.2.1 shall be amended to read as follows: Dimensions. Fire lanes and other emergency access routes shall have an unobstructed width of not less than 20 feet, an unobstructed width of 26 feet if it has a fire hydrant, and an unobstructed vertical clearance of not less than 14 feet. Turning radii, weight capacity, marking and all other dimensions or factors affecting fire lanes or emergency access routes shall be as specified in the Code unless otherwise approved by the Fire Marshal, in the exercise of reasonable discretion. (8) Section 901.6.1 shall be amended to read as follows: Standards. Fire protection systems shall be inspected, tested and maintained in accordance with the reference standards listed in Table 901.6.1, unless the Fire Marshal determines otherwise by rule, all such rules being on file in the office of the city secretary and in the office of the fire marshal. (9) Section 901.7 shall be amended to read as follows: Systems out of service. Where a fire protection system is out of service for any reason, or in the event of an excessive number of activations, the fire department shall be notified immediately and, where required by the Fire Marshal's Office, a fire watch shall be provided until the fire protection system has been repaired and returned to service. (10) Section 903.3.7 shall be amended to read as follows: Generally. Fire Department Connections shall be installed in accordance with section 912 of this code and will include the following: a. Free standing away from the collapse area. b. FDC height shall be between 28 inches and 36 inches. c. Shall have a fire hydrant within 150 feet. (11) Section 905.1 shall be amended to read as follows: Generally. Standpipe systems shall be provided as set forth in this section or as required by the Fire Marshal, in the exercise of reasonable discretion. (12) Sections 1103.5 and 1105 shall be excluded, omitted or unenforceable. (13) Section 5601.1.3 shall be amended to read as follows: Generally. The manufacture, possession, storage, sale, transportation, use and/or handling of fireworks or pyrotechnic material of any type are prohibited in the City of McAllen except as noted below: Exception. Approved events organized and conducted by licensed fireworks and pyrotechnic professionals where all necessary safety precautions are reviewed by the Fire Department and observed on site. (14) Section 5003.1.1 shall be amended by the addition of the following language: 5003.1.1 Location. Facilities storing hazardous, flammable or combustible liquids or materials in excess of the quantities listed in Tables 5003.1.1(1) through 5003.1.1(4) that are installed or relocated after the adoption of this provision, may only be located as approved by the Fire Marshal, in the exercise of reasonable discretion. (15) 5608.2.2. Use of pyrotechnics before a proximate audience is amended by adding Section 5608.2.2.1 (Inside Use of Pyrotechnics) as follows: 5608.2.2.1 Inside Use of Pyrotechnics. The use of pyrotechnics inside of a building shall be unlawful unless authorized and approved in writing by the Fire Marshal prior to the issuance of a permit. The Fire Marshal may require the owner or person in possession or control of the building or premises to provide without charge to the department a technical opinion and report stating whether harmful smoke would be produced and pose a health hazard to the public. The opinion and report shall be prepared by a qualified engineer, specialist, laboratory, or fire safety specialty organization acceptable to the Fire Marshal and the owner. A permit for the use of pyrotechnics shall be issued when approved by the Fire Marshal. Application for a permit shall be made in writing 30 days prior to the use of pyrotechnics. (16) Section 5608.2. Permit application is amended by adding Sections 5608.2.3 (Procedure for Applying; Permit for Fireworks Display) through 5608.2.8 (Duties of Permittee) as follows: 5608.2.3 Procedure for Applying; Permit for Fireworks Display. A permit applicant shall, at least 30 days before using fireworks, file with the Fire Marshal a completed permit application showing the: a) | Pyrotechnics: 1. | Business address; 2. | Proof of legal competency; and 3. | Record of previous experience with fireworks. b) | Address of the proposed display; c) | Amount, type, and class of fireworks to be used; d) | Address of the company supplying the fireworks; e) | Date of proposed display; f) | Starting and ending times of the proposed display; and g) | Diagram of the proposed display grounds, detailing: 1. | Firing points; 2. | Location of buildings and highways on or adjoining the grounds; 3. | Spectator restraining lines; and 4. | Overhead obstructions. h) | Completed permit application to the Fire Marshal including the surety bond or insurance coverage required by State Law. The Fire Marshal shall, within five days from date of the completion of the requirements in Subsection (l) of this section, approve or refuse to approve the permit. If the Fire Marshal refuses to approve issuance, he shall immediately send to the applicant by certified mail, return receipt requested, a written statement explaining the basis of the refusal. 5608.2.4. Refusal to Issue. The Fire Marshal may refuse to approve issuance of a permit if the applicant: 1. | Intentionally makes a false statement as to a material matter in the permit application; 2. | Is a fugitive from justice; 3. | Is under a felony indictment; 4. | Has been finally convicted of a felony offense within that five-year period immediately preceding the filing of the application; 5. | Has been finally convicted of a misdemeanor violation of an explosives law or regulation within the two-year period immediately preceding filing of the application; 6. | Held a permit issued under this article, which permit was revoked within that one-year period immediately preceding the filing of the application; 7. | Has been adjudicated a mental defective; is an unlawful user of, or addicted to, a controlled substance or dangerous drug, or suffers from any other handicap, infirmity, defect, or condition which might reasonably diminish his competency to safely conduct the proposed activity or would create an unreasonable risk of injury to life or property in the performance of the proposed activity. 5608.2.5. Revocation of Permit. The Fire Marshal shall revoke a permit if the permittee: 1. | Intentionally makes a false statement as to a material matter in the permit application; 2. | Knowingly allows another to use his permit; 3. | Violates a term or condition of the permit; 4. | Fails within the applicable time period to comply with an order or notice on him under this article; or 5. | Fails to discharge a duty imposed on him by this Section. The Fire Marshal shall, within five days from the date of revocation, send to the permittee by certified mail, return receipt requested, a written statement explaining the basis of the revocation. 5608.2.6. Appeal of Permit Refusal or Revocation. If the Fire Marshal refuses to issue a permit under this section, that action is final unless the applicant or permittee, within 10 days after receiving a written notice of the action, files a written appeal with the chairman of the Board of Appeals. 5608.2.7. Bond. The permittee shall furnish a bond or certificate of insurance in the minimum amount of One Million Dollars. The Fire Marshal may increase the amount of the required bond or insurance when he deems it advisable. 5608.2.8. Duties of Permittee. A permittee shall: 1. | Upon request, make his permit available for inspection to a member of the Fire Department, Police Officer, or any other authorized person; 2. | Notify the Fire Marshal of the loss or destruction of an unexpired permit, notice to be given immediately upon discovery of the loss or destruction; 3. | Secure a replacement permit for that lost or destroyed; 4. | Comply immediately with the Fire Marshal's order to dispose of fireworks which become hazardous during the performance of this permitted activity; and 5. | Return his permit to the Fire Marshal immediately upon its expiration, together with a statement detailing the cause of expiration and the disposition of unused fireworks. (17) The following appendices shall be excluded, omitted or unenforceable; • | J–Building Information Sign; • | K–Construction requirements for Existing Ambulatory Care Facilities (appendix to section 1105); • | M–High Rise Buildings—Retroactive automatic sprinkler requirement. (b) A copy of the 2024 International Fire Code shall be on file in the office of the City Secretary and two copies of such code shall be on file in the office of the Fire Marshal.
( 1966 Code, § 14-18 ; Ordinance 1992-82 , § I, adopted 10/12/1992 ; Ordinance 2002-64 , § 1, adopted 9/24/2002 ; Ordinance 2006-84 , § 3, adopted 8/14/2006 ; Ordinance 2009-07 , § X, adopted 1/26/2009 ; Ordinance 2012-91 , § I, adopted 12/10/2012 ; Ordinance 2013-62 , § I, adopted 8/12/2013 ; Ordinance 2020-41 , § I(Exh. A), adopted 8/24/2020 ; Ordinance 2026-79 adopted 8/10/2026 )
Ask a question about McAllen law
Corpus searches the McAllen sections it holds and shows the ones that match, with their citations. Free, no sign-in.