§ 110-49 — Backflow, siphonage
Code of Ordinances of the City of McKinney, Texas (Codified through Ordinance No. 2022-12-145, enacted December 20, 2022 (Supp. No. 37 archive; publisher-stale)) · McKinney Code of Ordinances § 110-49
Corpus is an independent public-information project, not the official City of McKinney website. Stable reference: corpuslaw.us/code/a25d0d14-a012-4546-89cf-a360681bd256
Sec. 110-49. - Backflow, siphonage.
(a) No water connection from the water system shall be allowed to any residence or establishment where an actual or potential contamination hazard exists unless the water system is first protected from contamination. (1) At any residence or establishment where an actual or potential contamination hazard exists, additional protection shall be required at the meter in the form of an air gap or backflow prevention assembly. The type of backflow prevention assembly required shall be determined by the specific potential hazard identified in 30 V.T.C.A., Administrative Code § 290.47(f). (2) At any residence or establishment where an actual or potential contamination hazard exists and an adequate internal cross-connection control program is in effect, backflow protection at the water service entrance or meter is not required. a. An adequate internal cross-connection control program shall include an annual inspection and testing by a licensed backflow prevention assembly tester on all backflow prevention assemblies used for health hazard protection. b. Customer shall provide copies of all such inspection and test reports to the city approximately one month prior to the annual anniversary of the customer's connection to the water system. c. Customer's failure to provide such inspection and test reports to the city may result in penalty, fine or the disconnection of service. (b) Overhead bulk water dispensing stations must be provided with an air gap between the filling outlet hose and the receiving tank to protect against back siphonage and cross-contamination. (c) All backflow prevention assemblies that are required according to this section and the table located in 30 V.T.C.A., Administrative Code § 290.47(f) shall be tested upon installation and immediately after repairs or relocation by a licensed backflow prevention assembly tester and certified to be operating within the required specifications. In addition, all backflow prevention assemblies that are installed to provide protection against health hazards shall be tested and certified to be operating within the required specifications at least annually by a backflow prevention assembly tester licensed by the TCEQ utilizing gauges conforming to the requirements of 30 V.T.C.A., Administrative Code § 290.44(h). (1) The backflow prevention assembly tester shall include the test gauge serial numbers on the backflow prevention assembly test and maintenance report, completed on TCEQ Form 20700 or an equivalent form approved by the TCEQ, to ensure such gauges have been tested for accuracy. (2) A test report must be completed by the recognized backflow prevention assembly tester for each assembly tested. The signed and dated original must be submitted to the city for recordkeeping purposes. (d) The use of a backflow prevention assembly at the service connection shall be considered as additional backflow protection and shall not negate the use of backflow protection on internal hazards as outlined and enforced by the plumbing code.
(Ord. No. 2020-04-026, § 7, 4-7-2020)
Ask a question about McKinney law
Corpus searches the McKinney sections it holds and shows the ones that match, with their citations. Free, no sign-in.