Sec. 122-32. - Amendments to International Plumbing Code.
The city council further adopts the recommended amendments to the 2021 Edition of the International Plumbing Code prepared by the North Central Texas Council of Governments, dated July 2021, attached hereto as Attachment D (the "IPC Amendments"). The International Plumbing Code and the IPC Amendments shall be further amended as follows: (1) Section 101.1 is hereby revised to read as follows: [A] 101.1 Title. These regulations shall be known as the Plumbing Code of the CITY OF MCKINNEY, TEXAS, hereinafter referred to as "this Code." (2) Section 103.1 is hereby revised to read as follows: [A] 103.1 Creation of enforcement agency. The BUILDING INSPECTIONS/PERMITS DEPARTMENT OF THE CITY OF MCKINNEY, TEXAS is hereby created and the official in charge thereof shall be known as the Chief Building Official. (3) Section 312.10.1, "Inspections" is hereby amended to read as follows: 312.10.1 Inspections. Annual inspections shall be made of all backflow prevention assemblies and air gaps to determine whether they are operable. In the absence of local provisions, the owner is responsible to ensure that testing is performed. (4) Section 312.10.2, "Testing" is hereby amended to read as follows: 312.10.2 Testing. Reduced pressure principle backflow preventer assemblies, double check-valve assemblies, pressure vacuum breaker assemblies, reduced pressure detector fire protection backflow prevention assemblies, double check detector fire protection backflow prevention assemblies, hose connection backflow preventers, and spill-proof vacuum breakers shall be tested at the time of installation, immediately after repairs or relocation and at least annually. The testing procedure shall be performed in accordance with applicable local provisions. In the absence of local provisions, the owner is responsible to ensure that testing is done in accordance with one of the following standards: [rest to remain the same….]
(Code 1982, § 34-18; Ord. No. 1632, § 1(F), 3-18-1986; Ord. No. 1826, § I(B), 2-21-1989; Ord. No. 92-02-03, § I(D), 2-18-1992; Ord. No. 95-02-10, § I(B)—(D), 2-7-1995; Ord. No. 2001-05-060, §§ 2, 3, 5-15-2001; Ord. No. 2008-05-050, § 6, 5-20-2008, eff. 7-1-2008; Ord. No. 2013-07-061, § 6, 7-16-2013; Ord. No. 2018-01-001, § 4, 1-2-2018; Ord. No. 2020-01-001, § 4, 1-7-2020; Ord. No. 2022-11-124 , § 4, 11-1-2022)
Ask a question about McKinney law
Corpus searches the McKinney sections it holds and shows the ones that match, with their citations. Free, no sign-in.