§ 84-16 — Grease traps/interceptors
Code of Ordinances of the City of McKinney, Texas (Codified through Ordinance No. 2022-12-145, enacted December 20, 2022 (Supp. No. 37 archive; publisher-stale)) · McKinney Code of Ordinances § 84-16
Corpus is an independent public-information project, not the official City of McKinney website. Stable reference: corpuslaw.us/code/a1c6cd4f-d354-4850-9440-fd736aa2b331
Sec. 84-16. - Grease traps/interceptors.
(a) The owner or operator of premises from which industrial waste material is discharged shall provide grease traps/interceptors for the proper handling of liquid wastes. (b) Grease traps/interceptors must be of a type and capacity approved by the director to be in compliance with all applicable local, state, and federal regulations, including the city's Plumbing Code, the Texas Administrative Code, and the 2018 International Plumbing Code so as to adequately handle grease trap waste and must be located so that they are easily accessible for cleaning, inspection, and monitoring. To the extent possible, grease traps should not be located in drive thru lanes. Sample ports should be installed on the grease traps and located in such a way as to be easily accessible. (c) Grease traps/interceptors must be cleaned in such a manner that the volume of grease trap waste removed from each grease trap/interceptor equals the nominal volume capacity of each respective grease trap/interceptor whenever it is cleaned. A grease trap/interceptor located upon the premises of a food establishment must be 100 percent pumped out: (1) Every 90 days; (2) When at least 25 percent or more of the wetted height of the grease trap/interceptor, as measured from the bottom of the grease trap/interceptor to the invert of the outlet pipe, contains floating materials, sediment, oils, or grease; (3) At a frequency specified by a variance granted by the director; (4) When the discharge exceeds any local, state, or federal limit; or (5) If the director determines more frequent service, a single event service or scheduled service is necessary due to a history of noncompliance or for the proper operation of the grease trap. (d) Each grease trap/interceptor shall be fully evacuated unless the trap volume is greater than the tank capacity on the vacuum truck in which case the transporter shall arrange for additional transportation capacity so the trap is fully evacuated within a 24-hour period, in accordance with 30 V.T.C.A., Administrative Code, ch. 312, § 312.143, as amended. (e) If a person ceases operation of a grease trap/interceptor, the person is required to pump the trap before abandoning the operation. If the operator fails to empty a trap, the owner shall be held responsible for evacuation of the grease trap/interceptor. (f) If notified by the director that a grease trap is not functioning properly in violation of federal, state, and/or local standards or regulations, the owner or operator of said grease trap shall install and maintain an approved grease trap and/or repair said grease trap as necessary. (g) Food establishments shall install and maintain a grease/trap interceptor in accordance with chapter 46 of the Code of Ordinances, as amended. (h) Self-cleaning provision. (1) Grease trap self-cleaning operators must receive approval from the director to remove grease from their own grease traps(s) located inside a building, and continue to do so until ownership change or upgrade facilities, provided: a. The grease trap is no more than 15 gallons in liquid/operating capacity; b. Proper on-site material disposal methods are implemented (e.g. absorb liquids into solid form and dispose into trash); c. The local solid waste authority allows such practices; d. Grease trap waste is placed in a leak proof, sealable container(s) and placed in the trash; and e. Detailed records on these activities are maintained. (2) Grease trap self-cleaning operators must submit a completed self-cleaning request to the director for approval. The written request shall include the following information: a. Business name and street address; b. Grease trap/interceptor operator name, title, and phone number; c. Description of maintenance frequency, method of disposal, method of cleaning and size (in gallons) of the grease trap/interceptor; and d. Signed statement that the operator will maintain records of waste disposal and produce them for compliance inspections. (3) Grease trap self-cleaning operators must adhere to all requirements, including those procedures and detailed record keeping requirements outlined in their application, to ensure compliance with this chapter. A maintenance log shall be kept by grease trap self-cleaning operators that indicates, at minimum, the following information: a. Date the grease trap/interceptor was serviced; b. Name of the person servicing the grease trap/interceptor; c. Waste disposal method used; d. Gallons of grease removed and disposed of; e. Waste oil added to grease trap/interceptor waste; and f. Signature of the operator after each cleaning that certifies that all grease was removed, disposed of properly, grease trap/interceptor was thoroughly cleaned, and that all parts were replaced and in operable condition. These records should be kept on-site for a minimum of three years. (4) Self-cleaning operators who accrue violation(s) will be subject to enforcement action including fines and/or removal from the self-cleaning program described herein.
(Ord. No. 2020-11-074, § 3, 11-3-2020)
Ask a question about McKinney law
Corpus searches the McKinney sections it holds and shows the ones that match, with their citations. Free, no sign-in.