Sec. 16-605. - Installation and maintenance requirements.

(a) Installations. (1) Food processing, food service and/or multi-family facilities, automotive services or any other facilities, new or existing, that produce liquid waste, grease, oils, or grit detrimental to the City or NTMWD wastewater system, shall be required to design, install, operate and maintain a grit trap and grease trap/interceptor in accordance with the latest edition, adopted by the City, of the International Plumbing Code or other applicable ordinances. Undersized grease traps from a prior use must be replaced with an appropriately sized grease traps if applicable. For new construction, grease traps/interceptors shall be installed and inspected prior to issuance of a certificate of occupancy. (2) All grease trap/interceptor designs must be sealed by a State of Texas Professional Engineer in accordance with the latest edition, adopted by the City, of the International Plumbing Code. All pre-manufactured grease traps/interceptors are considered pre-certified designs. Owners shall keep all design plans readily accessible for inspection purposes. (3) All grease trap/interceptor designs shall include a sample port of adequate size to facilitate effluent sampling. (b) Cleaning and Maintenance. (1) Grease traps/interceptors shall be operated and maintained in accordance with the manufacturers recommendations and maintained in an efficient operation condition at all times. (2) Each grease trap pumped shall be fully evacuated unless the trap volume is greater than the tank capacity on the vacuum truck in which case the transporter shall arrange for additional transportation capacity so that the trap is fully evacuated within a 24-hour period, in accordance with 30 Texas Administrative Code § 312.143, as amended. (c) Cleaning Schedules. (1) Grease traps/interceptors shall be cleaned as often as necessary: to ensure that sediment and floating materials do not accumulate to impair the efficiency of the grease trap/interceptor; to ensure the discharge is in compliance with local discharge limits; and to ensure no visible grease is observed in discharge. (2) Grease traps/interceptors subject to these standards shall be completely evacuated a minimum of two (2) times annually, or more frequently when: a. Twenty-five (25) percent or more of the wetted height of the grease trap/interceptor, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, oils, or greases; or b. The discharge exceeds BOD, COD, TSS, FOG, pH, or other pollutant levels established by the POTW; or c. If there is a history of noncompliance. (3) In any event, a grease trap/interceptor shall be fully evacuated and cleaned twice annually and inspected annually. (d) Manifest requirements. (1) Each pump-out of a grease trap/interceptor must be accompanied by a manifest as outlined in Article IV, Section 16-135 to be used for record keeping purposes. (2) Copies of manifests shall be retained for three (3) years and be readily available for review by the POTW. (e) City inspections. (1) Manifests. The City's Health/Utilities Divisions shall perform inspections a minimum of once a year required transporter manifest records as part of their inspection program and will receive and file the City's manifest copy. (2) Grease traps. The City Utilities Division will perform periodic physical inspections of grease traps/interceptors. a. Inspections will determine a point in time near the end of the current cleaning frequency for inspection. If twenty-five (25) percent or more of the wetted height of the grease trap/interceptor, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, oils, or greases, the cleaning and inspection frequency will be increased. Inspections will determine if the current cleaning frequency is sufficient or if the cleaning needs to be performed at a different frequency. This may be more or less often than the current cleaning frequency. b. A copy of the City grease trap/interceptor inspection report will be discussed with, provided to, and signed by the generator's on-duty manager or senior representative that is present for duty at the time. c. Facilities that exceed the twenty-five (25) percent criteria at the time of City inspection are required to service their grease trap within ten (10) calendar days after the date of the inspection. This will be noted on the inspection report. d. Facilities will be notified by mail by the City if their cleaning frequency has changed from the current interval based on the results of the City's physical grease trap/interceptor inspections. e. Regardless of grease trap inspection observations, facilities that establish a history of generating illicit discharges, sewer backups, or sanitary sewer overflows due to grease deposition in the grease trap, floor drains, or in their sewer lateral or main may be required to implement grease trap cleaning more often than is currently performed. f. City staff will maintain records of the currently required cleaning interval. g. In the event of a sewer overflow, an immediate cleaning will be required within twenty-four (24) hours which will require a re-inspection by the City. (f) Alternative treatment. (1) Offense. A person commits an offense if the person introduces, or causes, permits, or suffers the introduction of any surfactant, solvent or emulsifier into a grease trap. Surfactants, solvents and emulsifiers are materials which allow the grease to pass from the trap into the collection system, and include but are not limited to, enzymes, soap, diesel, kerosene, terpene, and other solvents. (2) Affirmative defense. It is an affirmative defense that the use of surfactants or soaps is incidental to normal kitchen hygiene operations. (3) Bioremediation media as referenced in Chapter 16, Article V may be used with the POTW's approval if the person has proved to the satisfaction of the POTW that laboratory testing which is appropriate for the type of grease trap to be used has verified that: a. The media is a pure live bacterial product which is not inactivated by the use of domestic or commercial disinfectants and detergents, strong alkalis, acids, and/or water temperatures of 160/F (71/C). b. The use of the media does not reduce the buoyancy of the grease layer in the grease trap and does not increase the potential for oil and grease to be discharged to the sanitary sewer. c. The use of the bioremediation media does not cause foaming in the sanitary sewer. d. The BOD, COD, and TSS discharged to the sanitary sewer after use of the media does not exceed the BOD, COD, and TSS which would be discharged if the product were not being used and the grease trap was being properly maintained. pH levels must be between 5 and 11. (4) All testing designed to satisfy the criteria set forth in Section 16-209(f)(3) shall be scientifically sound and statistically valid. All tests to determine oil and grease, TSS, BOD, COD, pH, and other pollutant levels shall use appropriate tests which have been approved by the Environmental Protection Agency and the Texas Commission on Environmental Quality and which are defined in Title 40, Code of Federal Regulations, Part 136 or Title 30, Texas Administrative Code § 319.11, as amended. Testing shall be open to inspection by the POTW, and shall meet the POTW's approval.

(Ord. No. 4914, § 2(Exh. A), 11-15-21; Ord. No. 5061, § 8(Exh. G), 9-5-23)

Ask a question about Mesquite law

Corpus searches the Mesquite sections it holds and shows the ones that match, with their citations. Free, no sign-in.