2.501 - Multifamily residential development standards.

The standards set out below shall be required for multifamily uses in all districts and shall serve as guidelines for review of multifamily developments in PD districts. Multifamily developments or redevelopments that include more than twenty-five (25) dwelling units require Planned Development district zoning. A. Site plan. Submittal and approval of a site plan is required. The site plan shall show the proposed development including all items on the Site Plan Review Checklist kept on file in the Planning Office and all items required by this section. B. Lot and setback requirements. All multifamily and permitted non-residential uses in the A districts shall comply with the following lot and setback requirements. 1. Minimum lot size. Ten thousand (10,000) square feet. 2. Minimum lot width. Eighty (80) feet. 3. Minimum front and exterior side yards. Twenty-five (25) feet. 4. Minimum interior and rear yards. Adjacent shall mean that the building site in the A district abuts or is across an alley from a lot or tract in the specified district. a. Adjacent to AG, R or D district: Twenty-five (25) feet (Also see height regulations below for setbacks required for structures taller than one (1) story). b. Adjacent to A or nonresidential district: Fifteen (15) feet. C. Maximum stories. The maximum number of stories in an A district shall be: 1. Two-stories if less than two hundred (200) feet from a single-family residential zoning district. 2. Three-stories if two hundred (200)—three hundred (300) feet from a single-family residential zoning district. 3. Five-stories if more than three hundred (300) feet from a single-family residential zoning district. D. Exterior fire resistant construction requirements. All main structures shall be of fire resistant construction having at least seventy-five (75) percent of the total exterior walls, excluding doors and windows, constructed of brick or stone. E. Dwelling unit requirements. 1. Minimum dwelling size. Seven hundred twenty-five (725) square feet, provided that efficiency units may be five hundred (500) square feet. 2. Maximum number of efficiency units. Five (5) percent of total number of dwelling units in the development. 3. Minimum number of one-bedroom units. Fifty (50) percent of total number of dwelling units in the development. 4. Maximum number of units with three (3) or more bedrooms. Five (5) percent of the total number of dwelling units. 5. Basic facilities. a. Each dwelling unit will include the following: Washer and dryer hookups Security devices in accordance with the requirements of the Texas Property Code § 92.153, as amended. The entry to all dwelling units shall be from an interior hallway of the building, provided that private patios and balconies shall have access to the unit. b. Bathrooms shall be required as follows: One-bedroom and efficiency units shall have a minimum of one (1) full bathroom. Two-bedroom units shall have a minimum of one (1) full and one-half (½) bathrooms. Three- and four-bedroom units shall have a minimum of two (2) full bathrooms. Five (5) or more bedroom units shall have a minimum of two (2) full and one-half (½) bathrooms. F. Density. In the district specified, multifamily development shall not exceed the density specified below, provided that a planned development district may be granted to allow densities exceeding the maximums specified below. District | Maximum Density (Units/Acre) A-1 | 12* A-3 | 25* *The maximum density computation indicated is based on gross site acreage. In no case shall density be permitted to exceed twenty-five (25) units per acre on the net buildable area regardless of the gross acreage density computation unless approved as part of a planned development district. Net buildable area is the acreage of the portion of a tract which is not in a 100-year flood plain or will not be in the 100-year flood plain after reclamation. G. Screening and security. 1. Screening. Screening and buffering requirements for multifamily uses are set out in 1A.304. 2. Security fencing. Multifamily developments shall be required to provide security fencing and gates adequate to regulate and control access to the complex. In order to assure emergency access, all gate installations shall be in accordance with established rules and regulations of the Mesquite Fire Department. Fencing erected pursuant to this requirement shall be six (6) to eight (8) feet in height and shall be constructed of wrought iron with a maximum picket spacing of six (6) inches, or a long-span precast concrete decorative screening wall, brick, stone or vinyl. Only fencing of a non-solid construction is permitted within the front and exterior side yard setbacks, provided that all gates must be set back from the street right-of-way a minimum of twenty-five (25) feet. 3. Site security. All parking areas, common hallways and entrances shall be illuminated and have operational video surveillance. H. Open space and outdoor amenities. Open space and outdoor amenities shall be provided as follows for the use and enjoyment of the residents. 1. Open space requirement. Any multifamily site containing more than twelve (12) dwelling units shall be required to provide a minimum of four hundred (400) square feet of open space per dwelling unit. Open spaces shall not include any area with drainage structures, floodplain or within any required front or exterior side setback. Open spaces that count toward this requirement shall have a minimum dimension of twenty-five (25) feet and a minimum area of eight hundred (800) square feet. 2. Number of amenities. Any multifamily site with twelve (12) to forty-nine (49) dwelling units shall provide a minimum of one (1) outdoor amenity from the list of Outdoor Amenities Group A and one (1) from Outdoor Amenities Group B. Multifamily sites with fifty (50) or more dwelling units shall provide a minimum of two (2) outdoor amenities from the list of Outdoor Amenities Group A and two (2) from Outdoor Amenities Group B below. For each additional seventy-five (75) dwelling units on a property, one (1) additional outdoor amenity from Group A and Group B shall be provided. All amenities shall be of quality and construction similar to the type normally used in public parks. Outdoor Amenities—Group A Swimming pool Splash pad Sports courts—Regulation sized (such as basketball, volleyball, tennis) Playgrounds with a minimum of five (5) pieces of equipment and one thousand (1,000) square feet of area. Other amenities may be allowed as approved by the Director of Planning and Development Services. Outdoor Amenities—Group B Fire pit Outdoor cooking facilities Picnic areas to include dining tables and permanent shade structures Hot tub/spa Other amenities may be allowed as approved by the Director of Planning and Development Services. I. Indoor amenities. Any multifamily site with fifty (50) or more dwelling units shall provide a minimum of two (2) indoor amenities from the list of Indoor Amenities below. For each additional fifty (50) dwelling units on a property, one (1) additional indoor amenity shall be provided. Indoor Amenities Fitness room to include cardio and weight training equipment with a minimum area of three (3) square feet per dwelling unit Indoor pool Indoor hot tub/spa Business center to include at least two (2) computer stations, a printer, scanner, and photocopying device Media room with permanent television/movie viewing equipment and seating for a minimum of twenty (20) individuals Club room with a minimum of ten (10) square feet for each dwelling unit, but in no case less than one thousand five hundred (1,500) square feet. Club room shall include a sink, coffee bar, seating and tables Recreation room with equipment such as pool tables, ping pong, foosball, shuffle board or similar game equipment Other amenities may be allowed as approved by the Director of Planning and Development Services J. Landscape requirements. Landscaping shall be provided for all multifamily and all permitted nonresidential uses in the A district in accordance with the requirements set out in 1A.200, Landscape Requirements; provided however, that the minimum area required to be landscaped in multifamily developments shall be all open space areas with the exception of areas where outdoor amenities are located. K. Off-street parking requirements. 1. Calculation for number of spaces. a. Standard multifamily developments. (1) The number of parking spaces for standard multifamily developments shall be provided based on the number of bedrooms in each dwelling unit as follows: (a) Studio/Efficiency: 1 space per unit. Except when: (i) Studio/Efficiency unit ratio exceeds 10% of the total units: 1.25 spaces per unit. (ii) Studio/Efficiency unit ratio exceeds 20% of the total units: 1.5 spaces per unit. (b) One bedroom: 1.5 spaces per unit. (c) Two bedrooms or more: 2 spaces per unit. (2) The parking requirement shall be increased by ten (10) percent when both of the following are true: (a) The multifamily property is within three hundred (300) feet of a collector or local street where single-family homes, a school, or a public park front the collector or local street; and said single-family homes, school, or public park are also within three hundred (300) feet of the multifamily property; and (b) Where such collector or local street and single-family homes, school, or park are not across an arterial street or freeway. b. Age-restricted multifamily communities. The number of parking spaces for age-restricted multifamily communities shall be 1.25 spaces per unit regardless of bedroom count. 2. Location. In no case shall parking be provided between any building and any public street, nor shall parking be permitted in any front or exterior side setback. 3. Covered parking. A minimum of fifty (50) percent of required parking spaces shall be covered spaces provided either in an enclosed garage, a multilevel garage, or under a carport. 4. Design, layout, and construction. All parking areas for multifamily uses shall comply with the requirements for nonresidential parking lots as set out in 3.400. L. Projections of architectural features. Cornices, eaves, chimneys, bay windows, balconies, canopies and fire escapes may project three (3) feet into any required yard, provided that such feature does not occupy more than one third (⅓) of the length of the building wall on which it is located. M. Accessory structures. Accessory structures shall be regulated in accordance with the requirements set out in 2.600. N. Refuse containers. Refuse containers, compactors and similar facilities shall be located a minimum of one hundred (100) feet from any property line abutting an AG, R or D district. All refuse containers shall be enclosed as required in the City of Mesquite Engineering Design Manual. O. Traffic impact analysis. The proposed construction of fifty (50) or more multifamily dwelling units, whether a new development or expansion of an existing development, shall require a traffic impact analysis. The traffic impact analysis shall include an analysis of pedestrian facilities serving the site. P. School impact analysis. All requests for rezoning for any development that includes twenty-five (25) or more multifamily dwelling units, whether a new development or expansion of an existing development, shall require an analysis of the expected impact on the public school system. The school impact analysis shall be submitted to the Director of Planning and Development Services and the applicable school district no less than seven (7) days prior to consideration of the zoning request by the Planning and Zoning Commission.

(Ord. No. 2669, 4-16-90; Ord. No. 2969, § 1, 5-2-94; Ord. No. 3343, § 1(4), 11-15-99; Ord. No. 3438, § 1, 8-20-01; Ord. No. 4398, § 1(9), 11-2-15; Ord. No. 4676, § 1(Exh. A(5)), 5-20-19; Ord. No. 5106, § 2(Exh. A), 5-6-24)

Ask a question about Mesquite law

Corpus searches the Mesquite sections it holds and shows the ones that match, with their citations. Free, no sign-in.