§ 5-321 — Local Amendments to the International Mechanical Code, 2024 Edition
Code of the City of Mesquite, Texas (Supp. No. 71: codified through Ordinance No. 5259, enacted July 20, 2026) · Mesquite City Code § 5-321
Corpus is an independent public-information project, not the official City of Mesquite website. Stable reference: corpuslaw.us/code/8a363c24-ed16-4fc5-b000-9797b19dc786
Sec. 5-321. - Local Amendments to the International Mechanical Code, 2024 Edition.
(a) Specific code provisions. Amendments included in this section are intended to be specific code provisions. If there is a conflict between a provision in the published International Mechanical Code (I.M.C.), 2024 Edition, and this section, the specific provisions of this section shall control. (b) Table of the local amendments. The following table contains the local amendments to the I.M.C., 2024 Edition. (1) Table Legend. a. Column 1: Item Reference Number b. Column 2: Related I.M.C. Code Section Number and Title c. Column 3: Local Amendment to I.M.C. d. (…): Dots (…) (i.e., an ellipsis) indicate the omission of intact and unchanged text which has not been reproduced for efficiency purposes. It is intended that the text in the I.M.C., not set forth in this section and instead denoted by dots (…), shall remain intact and unchanged from the language existing prior to adoption of this section. e. ( * * * ): Asterisks ( * * * ) indicate the omission of intact and unchanged text which has not been reproduced for efficiency purposes. It is intended that the text in the I.M.C., not set forth in this section and instead denoted by asterisks ( * * * ), shall remain intact and unchanged from the language existing prior to adoption of this section. (2) TABLE OF LOCAL AMENDMENTS TO THE 2024 INTERNATIONAL MECHANICAL CODE No. | IMC Code Section No. Title | Local Amendment to IMC 01 | IMC 101.1 Title. | Amend section in its entirety to read as follows: 101.1: Title. These regulations shall be known as the Mechanical Code of the City of Mesquite, Texas, ("Mesquite Mechanical Code") and may hereinafter be referred to as "this code." 02 | IMC 102.8 Referenced Codes and Standards. | Amend section in its entirety to read as follows: 102.8 Referenced Codes and Standards. The codes and standards referenced herein shall be those that are listed in Chapter 15 and such codes and standards, when specifically adopted, shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.8.1 and 102.8.2. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the adopted amendments. Any reference to NFPA 70 shall mean the National Electrical Code as adopted. Exception: Where enforcement of a code provision would violate the conditions of the listing of the equipment or appliance, the conditions of the listing and the manufacturer's installation instruction shall apply. 03 | IMC 105.1.1 Annual Permit. | Delete this section. 04 | IMC 105.1.2 Annual Permit Records. | Delete this section. 05 | IMC 105.3.2 Time Limitation of Application. | Amend section in its entirety to read as follows: 105.3.3. Time limitation of application. An application for a permit for any proposed work shall be deemed to have been abandoned 45-days after the date of filing, unless such application has been pursued in good faith or a permit has been issued; except that the Building Official is authorized to grant one or more extensions of time for additional periods not exceeding 45-days each. The extension shall be requested in writing and justifiable cause demonstrated. 06 | IMC 105.4.3 Expiration. | Amend section in its entirety to read as follows: 105.4.3. Expiration. Every permit issued shall expire and become null and void if (i) the permittee fails to commence work on the site authorized by such permit within 30-days after its issuance, or (ii) the permittee fails to have the work authorized on the site by such permit inspected during any 90-day period after the work has commenced. It shall be unlawful to commence or recommence work after a permit expires without obtaining a new permit or receiving on extension from the Building Official. The Building Official is authorized to grant, in writing, one or more extensions of time, for periods not more than 90-days each. The extension shall be requested in writing and justifiable cause demonstrated. 07 | IMC 105.4.4 Extensions. | Delete this section. 08 | IMC 105.4.7 Posting of Permit. | Delete this section. 09 | IMC 108.2 Schedule of Permit Fees. | Amend by adding a sentence [after the first and only sentence of the section] to read as follows: 108.2: Schedule of permit fees schedule. * * * See Mesquite City Code, Appendix D - Comprehensive Fee Schedule, for applicable fees. 10 | IMC 108.6 Refunds. | Amend section in its entirety to read as follows: 108.6: Refunds. In the case where a fee was paid or collected erroneously, the Building Official shall authorize a one hundred percent (100%) refund of said fee. In the case where a fee was paid or collected and when no work was performed under a permit issued in accordance with this Code, the Building Official shall authorize a partial refund, of not more than eighty percent (80%) of the permit fee, in accordance with this Section. The Building Official shall not authorize refunding of any fee paid except on written request filed by the original permittee not later than 180-days from the date of fee payment. 11 | IMC Section 112: Appeals. | Amend title and section in its entirety to read as follows: SECTION 112: APPEALS 112.1: General. Except as otherwise provided, any person shall have the right to appeal an administrative decision of the Building Official, Fire Official, or any other City official to the Building Standards Board, when said decision is relative to the application, enforcement, or interpretation of this Code. The Building Standards Board is established in Mesquite City Code, Chapter 20, Article IV, Division 4 (Building Standards Board). The process and procedures for appealing an administrative decision are set forth in Chapter 5, Article XIII (Appeals of Administrative Decisions to Building Standards Board). Appeal of an Administrative Decision relative to a Certificate of Occupancy: When an appeal of an administrative decision is relative to a Certificate of Occupancy the appeal shall be to the Board of Adjustment for its denial, revocation, suspension, or otherwise (in accordance with Mesquite Zoning Ordinance, Part 5, 5-100, Section 5-106 (Certificate of Occupancy)). The process and procedures for appealing an administrative decision relative to a Certificate of Occupancy, or any other administrative decision made under the Mesquite Zoning Ordinance, are set forth in Mesquite Zoning Ordinance, Part 5, 5-200, Section 5-210 (Appeals of Administrative Decisions to Board of Adjustment). 12 | IMC 114.1 Unlawful Acts. | Amend section in its entirety to read as follows: 114.1: Unlawful acts. It shall be unlawful for any person, firm, corporation, or entity to erect, construct, alter, extend, repair, move, remove, demolish, or occupy any building, structure, or equipment regulated by this code, or cause same to be done, in conflict with, or in violation of, any of the provisions of this code. 13 | IMC 114.2 Notice of Violation. | Amend section in its entirety to read as follows: 114.2: Notice of violation. The Building Official is authorized to serve a notice of violation or order on the owner of the premises, or any person, firm, corporation, or other entity responsible for the erection, construction, alteration, extension, repair, moving, removal, demolition, or occupancy of a building or structure, in violation of the provisions of this code, or in violation of a permit or certificate issued under the provisions of this code. Such order may direct the discontinuance of the illegal action or condition and the abatement of the violation. 14 | IMC 114.3 Prosecution of Violation. | Amend section in its entirety to read as follows: 114.3: Prosecution of violation. Failure to promptly comply with notice of violation issued by the Building Official shall constitute a separate violation of this code and may be prosecuted as such by the City. This section shall not be construed as requiring notification, or any other condition, to any proceeding seeking to address any violation of the provisions of this code. 15 | IMC 114.4 Violation Penalties. | Amend section in its entirety to read as follows: 114.4 Violation penalties. Any person who violates a provision of this code, or fails to comply with any of the requirements thereof, or who erects, constructs, alters or repairs a building or structure in violation of the approved construction documents or directive of the Building Official, or of a permit or certificate issue under the provisions of this code shall be subject to penalties as prescribed by law and herein in this Article. Nothing in this code shall be construed to interfere, inhibit, or otherwise affect the pursuit of legal remedies or proceedings to restrain, correct, abate, or otherwise address any violation of this code, or to remove or terminate unlawful occupancy of a premises in violation of the provisions of this code. 16 | IMC Section 202: General Definitions | Amend section by changing the definition for "Code Official" to read as follows: CODE OFFICIAL. The Building Official, or other authority designated by the Building Official, charged with the administration and enforcement of this Code. 17 | IMC Section 202: General Definitions | Add definition for "Effective Dispersal Volume Charge" as follows: EFFECTIVE DISPERSAL VOLUME CHARGE (EDVC). The maximum refrigerant charge permitted for an effective dispersal volume. 18 | IMC Section 202: General Definitions | Add definition for "Refrigerant Detection System" as follows: REFRIGERANT DETECTION SYSTEM. The product safety standard addresses both refrigerant detection systems and leak detection systems. In the product safety standard, a leak detection system is defined as "a sensing system which responds to refrigerant leaking from a refrigerating system." A leak detection system may include gas sensing, ultrasonic, or other such methods that meet the standards UL 60335-2-40/CSA C22.2 No. 60335-2-40 or UL 60335-2-89/CSA C22.2 No. 60335-2-89. [ASHRAE 15-2022: 3.1] 19 | IMC Section 202: General Definitions | Add definition for "Refrigerant Detector" as follows: REFRIGERANT DETECTOR. "Refrigerant sensor" is another term for refrigerant detector. A refrigerant sensor is a sensing element combined with electronic circuitry that provides a digital output or an analog signal output that corresponds to the sensed refrigerant gas concentration. [ASHRAE 15-2022: 3.1] 20 | IMC 306.3 Appliances in Attics. | Amend section in its entirety to read as follows: 306.3: Appliances in attics. Attics containing appliances shall be provided with an opening and unobstructed passageway large enough to allow removal of the largest appliance. The passageway shall be not less than 30 inches (762 mm) high and 22 inches (599 mm) wide and to more than 20 feet (6096 mm) in length measured along the centerline of the passageway from the opening to the appliance. The passageway shall have continuous solid flooring not less than 24 inches (610 mm) wide. A level service space not less than 30 inches (762 mm) deep and 30 inches (762 mm) wide shall be present at the front or service side of the appliance. The clear access opening dimensions shall be not less than 20 inches by 30 inches (508 mm by 762 mm), and large enough to allow removal of the largest appliance. As a minimum access to the attic space shall be provided by one of the following: 1. A permanent Stair. 2. A pull-down stair with a minimum 300 lb (136 kg) capacity. 3. An access door from an upper floor level. Exceptions: 1. The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening with the approval of the Code Official. 2. Where the passageway is unobstructed and not less than 6 feet (1829 mm) high and 22 inches (559 mm) wide for its entire length, the passageway shall be not greater than 50 feet (15,250 mm) in length. 21 | IMC 306.5.1 Sloped Roofs. | Amend section to read as follows: 306.5.1: Sloped Roofs. Where appliances, equipment, fans or other components that require service are installed on a roof having a slope of 3 units vertical in 12 units horizontal (25-percent slope) or greater and having an edge more than 30 inches (762 mm) above grade at such edge, a catwalk at least 16 inches in width with substantial cleats spaced not more than 16 inches apart shall be provided from the roof access to a level platform at the appliance. The level platform shall be provided on each side of the appliance or equipment to which access is required for service, repair or maintenance. The platform shall be not less than 30 inches (762 mm) in any dimension and shall be provided with guards. The guards shall extend not less than 42 inches (1067 mm) above the platform, shall be constructed so as to prevent the passage of a 21-inch-diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the International Building Code…[remainder of text unchanged]. * * * 22 | IMC 501.3 Exhaust Discharge. | Amend section by adding exception #4 to read as follows: 501.3: Exhaust Discharge. The air removed by every mechanical exhaust system shall be discharged outdoors at a point where it will not cause a public nuisance and not less than the distances specified in Section 501.3.1. The air shall be discharged to a location from which it cannot again be readily drawn in by a ventilating system. Air shall not be exhausted into an attic, crawl space, or be directed onto walkways. Exceptions: 1. Whole-house ventilation-type attic fans shall be permitted to discharge into the attic space of dwelling units having private attics. 2. Commercial cooking recirculating systems. 3. Where installed in accordance with the manufacturer's instructions and where mechanical or natural ventilation is otherwise provided in accordance with Chapter 4, listed and labeled domestic ductless range hoods shall not be required to discharge to the outdoors. 4. Toilet room exhaust ducts may terminate in a warehouse or shop area when infiltration of outside air is present. 23 | IMC 1104.2 Machinery Room. | Amend section by adding exception #3 to read as follows: Exceptions: * * * 3. Machinery Rooms are not required when in compliance with ASHRAE 15 Section 7.4. 24 | IMC 1104.3.1.1 Group A2L High-Probability Systems. | Add this new section to read as follows: 1104.3.1.1: Group A2L High-Probability Systems. High-probability systems using Group A2L refrigerants shall comply with ASHRAE 15 section 7.6. 25 | IMC 1109.2.5 Refrigerant Pipe Shafts. | Amend section by revising exception #2 as follows: 1109.2.5: Refrigerant pipe shafts. * * * [Existing text to remain] Exceptions: 1. [Existing text to remain.] 2. Piping in a direct refrigeration system using Group A1 where the refrigerant quantity does not exceed the limits of Table 1103.1 for the smallest occupied space through which the piping passes. 3. [Existing text to remain.] 3. [Existing text to remain.]
(Ord. No. 4801, § 2(Exh. F), 9-21-20; Ord. No. 4894, § 7(Exh. F), 9-7-21; Ord. No. 5061, § 3(Exh. B), 9-5-23; Ord. No. 5246, § 2(Exh. A), 5-18-26)
Ask a question about Mesquite law
Corpus searches the Mesquite sections it holds and shows the ones that match, with their citations. Free, no sign-in.