§ 5-51 — Local Amendments to the International Existing Building Code, 2024 Edition
Code of the City of Mesquite, Texas (Supp. No. 71: codified through Ordinance No. 5259, enacted July 20, 2026) · Mesquite City Code § 5-51
Corpus is an independent public-information project, not the official City of Mesquite website. Stable reference: corpuslaw.us/code/c8a29558-0f67-4229-922d-6e57ed02e92a
Sec. 5-51. - Local Amendments to the International Existing Building Code, 2024 Edition.
(a) Specific code provisions. Amendments included in this section are intended to be specific code provisions. If there is a conflict between a provision in the published International Existing Building Code (I.E.B.C.), 2024 Edition, and this section, the specific provisions of this section shall control. (b) Table of the local amendments. The following table contains the local amendments to the I.E.B.C., 2024 Edition. (1) Table Legend. a. Column 1: Item Reference Number b. Column 2: Related I.E.B.C. Code Section Number and Title c. Column 3: Local Amendment to I.E.B.C. d. (…): Dots (…) (i.e., an ellipsis) indicate the omission of intact and unchanged text which has not been reproduced for efficiency purposes. It is intended that the text in the I.E.B.C., not set forth in this section and instead denoted by dots (…), shall remain intact and unchanged from the language existing prior to adoption of this section. e. ( * * * ): Asterisks ( * * * ) indicate the omission of intact and unchanged text which has not been reproduced for efficiency purposes. It is intended that the text in the I.E.B.C., not set forth in this section and instead denoted by asterisks ( * * * ), shall remain intact and unchanged from the language existing prior to adoption of this section. (2) TABLE OF LOCAL AMENDMENTS TO THE 2024 INTERNATIONAL EXISTING BUILDING CODE No. | IBC Code Section No. Title | Local Amendment to IEBC 01 | IEBC 101.1 Title. | Amend section in its entirety to read as follows: 101.1: Title. These regulations shall be known as the Existing Building Code of the City of Mesquite, Texas, ("Mesquite Existing Building Code") hereinafter referred to as "this code." 02 | IEBC 102.4 Referenced Codes and Standards. | Amend section to read as follows [the exception remains unchanged]: [A] 102.4: Referenced codes and standards. The codes, when specifically adopted, and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.4.1 and 102.4.2. * * * 03 | IEBC 102.4.3 Electrical. | Add new section to read as follows: 102.4.3: Electrical. The provisions of the local adopted Electrical Code shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures, fittings and appurtenances thereto. 04 | IEBC 105.1.1 Annual Permit. | Delete this section. 05 | IEBC 105.1.2 Annual Permit Records. | Delete this section. 06 | IEBC 105.2.2 Repairs. | Amend by deleting # 1 [the remainder of the section is unchanged]. 07 | IEBC 105.3.2 Time Limitation of Application. | Amend section in its entirety to read as follows: 105.3.2: Time limitation of application. An application for a permit for any proposed work shall be deemed to have been abandoned 45-days after the date of filing, unless such application has been pursued in good faith or a permit has been issued; except that the Building Official is authorized to grant one or more extensions of time for additional periods not exceeding 45-days each. The extension shall be requested in writing and justifiable cause demonstrated. 08 | IEBC 105.5 Expiration. | Amend section in its entirety to read as follows: 105.5: Expiration. Every permit issued shall expire and become null and void if (i) the permittee fails to commence work on the site authorized by such permit within 30-days after its issuance, or (ii) the permittee fails to have the work authorized on the site by such permit inspected during any 90-day period after the work has commenced. It shall be unlawful to commence or recommence work after a permit expires without obtaining a new permit or receiving on extension from the Building Official. The Building Official is authorized to grant, in writing, one or more extensions of time, for periods not more than 90-days each. The extension shall be requested in writing and justifiable cause demonstrated. 09 | IEBC 108.2 Schedule of Permit Fees. | Amend by adding a sentence [after the first and only sentence of the section] to read as follows: 108.2: Schedule of permit fees. * * * See Mesquite City Code, Appendix D - Comprehensive Fee Schedule, for applicable fees. 10 | IEBC 108.6 Refunds. | Amend section in its entirety to read as follows: 108.6: Refunds. In the case where a fee was paid or collected erroneously, the Building Official shall authorize a one hundred percent (100%) refund of said fee. In the case where a fee was paid or collected and when no work was performed under a permit issued in accordance with this Code, the Building Official may authorize a partial refund, of not more than eighty percent (80%) of the permit fee, in accordance with this Section. The Building Official shall not authorize refunding of any fee paid except on written application filed by the original permittee not later than 180-days from the date of fee payment. 11 | IEBC 109.3.11 Final Inspection. | Amend section in its entirety to read as follows: 109.3.11: Final Inspection. Every permit required by this Code shall pass a final inspection. 12 | IEBC Section 112: Appeals. | Amend title and section in its entirety to read as follows: SECTION 112: APPEALS 112.1: General. Except as otherwise provided, any person shall have the right to appeal an administrative decision of the Building Official, Fire Official, or any other City official to the Building Standards Board, when said decision is relative to the application, enforcement, or interpretation of this Code. The Building Standards Board is established in Mesquite City Code, Chapter 20, Article IV, Division 4 (Building Standards Board). The process and procedures for appealing an administrative decision are set forth in Chapter 5, Article XIII (Appeals of Administrative Decisions to Building Standards Board). Appeal of an Administrative Decision relative to a Certificate of Occupancy: When an appeal of an administrative decision is relative to a Certificate of Occupancy the appeal shall be to the Board of Adjustment for its denial, revocation, suspension, or otherwise (in accordance with Mesquite Zoning Ordinance, Part 5, 5-100, Section 5-106 (Certificate of Occupancy)). The process and procedures for appealing an administrative decision relative to a Certificate of Occupancy, or any other administrative decision made under the Mesquite Zoning Ordinance, are set forth in Mesquite Zoning Ordinance, Part 5, 5-200, Section 5-210 (Appeals of Administrative Decisions to Board of Adjustment). 13 | IEBC Section 202: General Definitions | Amend section by changing the definition for "Code Official" to read as follows: CODE OFFICIAL. The Building Official, or other authority designated by the Building Official, charged with the administration and enforcement of this Code. 14 | IEBC Section 202: General Definitions | Amend section by changing the definition for "Existing Structure" to read as follows: EXISTING STRUCTURE. A building, structure or space with an approved final inspection issued under a code edition which is at least two published code editions preceding the currently adopted building code; or a change of occupancy. 15 | IEBC Section 202: General Definitions | Amend section by changing the definition for "Existing Building" to read as follows: EXISTING BUILDING. A building, structure, or space with an approved final inspection issued under a code edition which is at least 2 published code editions preceding the currently adopted building code; a building, structure or space that is undergoing a change of occupancy or use. 16 | IEBC 302.2 Additional Codes. | Amend section in its entirety to read as follows: 302.2: Additional Codes. Alterations, repairs, additions and changes of occupancy to, or relocation of, existing buildings and structures shall comply with the provisions for alterations, repairs, additions and changes of occupancy or relocation, respectively, in this code and the International Energy Conservation Code , International Fire Code, International Fuel Gas Code, International Mechanical Code, International Plumbing Code, International Private Sewage Disposal Code, International Property Maintenance Code, International Residential Code and NFPA 70 and any other Codes or other ordinances adopted by the authority having jurisdiction. Where provisions of the other codes conflict with provisions of this code, the provisions of this code shall take precedence. 17 | IEBC 306.1 Scope. | Add an exception to read as follows: 306.1: Scope. * * * Exception: 1. Components of projects regulated by and registered with Architectural Barriers Division of Texas Department of Licensing and Regulation shall be deemed to be in compliance with the requirements of this chapter. 18 | IEBC 309.2.1 Automatic Sprinkler Systems. | Delete this section. 19 | IEBC 401.3 Flood Hazard Areas. | Delete this section. 20 | IEBC 405.2.6 Flood Hazard Areas. | Delete this section. 21 | IEBC 502.2 Flood Hazard Areas. | Delete this section. 22 | IEBC 503.2 Flood Hazard Areas. | Delete this section. 23 | IEBC 503.3 Existing Structural Elements Carrying Gravity Load. | Amend by deleting the exception # 2 in its entirety. 24 | IEBC 503.18 Enhanced Classroom Acoustics | Add the following text after the existing paragraph to read as follows: IEBC 503.18: Enhanced classroom acoustics. * * * Compliance with the Texas Accessibility Standards is not considered equivalent compliance for the purpose of enforcement of this code section. 25 | IEBC 504.1.2 Existing Fire Escapes. | Amend section in its entirety to read as follows: 504.1.2: Existing fire escapes. Existing fire escapes shall continue to be accepted as a component in the means of egress in existing buildings only. Existing fire escapes shall be permitted to be repaired or replaced. 26 | IEBC 504.1.3 New Fire Escapes. | Delete this section. 27 | IEBC 507.3 Flood Hazard Areas. | Delete this section. 28 | IEBC 701.3 Flood Hazard Areas. | Delete this section. 29 | IEBC 702.7 Materials and Methods. | Amend section in its entirety to read as follows: 702.7: Materials and methods. All new work shall comply with the materials and methods requirements in the International Building Code, International Energy Conservation Code, International Mechanical Code, National Electrical Code, and International Plumbing Code, as applicable, that specify material standards, detail of installation and connection, joints, penetrations, and continuity of any element, component, or system in the building. 30 | IEBC 705.3 Roof Recover. | Amend by deleting the exception # 3 in its entirety. 31 | IEBC 802.5.1 Minimum Requirement. | Amend section in its entirety to read as follows: 802.5.1: Minimum requirement. Every portion of an open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps, and landings that is more than 30 inches (762 mm) above the floor or grade below and is not provided with guards, or those in which the existing guards are judged to be in danger of collapsing, shall be provided with guards. 32 | IEBC 803.1 Scope. | Add the following text at the end of the existing section to read as follows: 803.1: Scope. * * * For the purpose of fire sprinkler protection and fire alarm requirements included in this section, the work area shall be extended to include at least the entire tenant space or spaces bounded by walls capable of resisting the passage of smoke containing the subject work area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or other exit access shall be protected in its entirety on that particular floor level. 33 | IEBC 803.3 Standpipes. | Amend section in its entirety to read as follows and delete the exceptions: 803.3: Standpipes. Refer to Section 1103.6 of the Fire Code for retroactive standpipe requirements. 34 | IEBC 804.2 General. | Delete exception #1. 35 | IEBC 804.5.1.2 Fire Escapes Required. | Amend section in its entirety to read as follows: 804.5.1.2: Fire escapes required. For other than Group I-2, where more than one exit is required, an existing escape complying with section 805.3.1.2.1 shall be accepted as providing one of the required means of egress. 36 | IEBC 804.5.1.2.1 Fire Escape Access and Details. | Amend section to read as follows: 804.5.1.2.1: Fire escape access and details. 1. [Remain unchanged] 2. [Remain unchanged] 3. Delete. 4. [Remain unchanged] 5. In all buildings of Group E occupancy up to and including the 12th grade, buildings of Group I occupancy, boarding houses, and childcare centers, ladders of any type are prohibited on fire escapes used as a required means of egress. 37 | IEBC 804.7.2 Transoms. | Amend section to read as follows: 804.7.2: Transoms. In all buildings of Group B, E, I-1, I-2, R-1 and R-2 occupancies, … [Remainder unchanged]. * * * 38 | IEBC 806.4 Residential Occupancies. | Amend by adding the following sentence to the end of the section to read as follows: 806.4: Residential occupancies. * * * Reconfigured or converted spaces shall comply with the requirements of NFPA 70. 39 | IEBC 904.1 Automatic Sprinkler Systems | Amend by adding the following text [after the first and only sentence of the section] to read as follows: 904.1: Automatic sprinkler systems. For the purpose of fire sprinkler protection and fire alarm requirements included in this section, the work area shall be extended to include at least the entire tenant space or spaces bounded by walls containing the subject work area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or other exit access shall be protected in its entirety on that particular floor level. 40 | IEBC 904.1.1 High-Rise Buildings. | Amend section in its entirety to read as follows: 904.1.1: High-rise buildings. An automatic sprinkler system shall be provided in work areas of high-rise buildings. 41 | IEBC 1011.2 Fire Protection Systems. | Amend section in its entirety to read as follows: 1011.2: Fire protection systems. Where a change in Occupancy Classification or Group occurs, fire protection systems shall be provided in accordance with the International Fire Code and International Building Code. 42 | IEBC 1011.2.1 Automatic Fire Sprinkler System. | Amend section in its entirety and delete exceptions to read as follows: 1011.2.1: Automatic fire sprinkler system. The installation of an automatic sprinkler system shall be required where there is a change of occupancy classification and Chapter 9 of the current International Building Code requires an automatic sprinkler system based on the new occupancy or where there is a change of occupancy within the space where there is a different fire protection system threshold requirement in Chapter 9 of the current International Building Code than exists in the current building or space. The installation of the automatic sprinkler system shall be required within the area of the change of occupancy and areas of the building not separated horizontally and vertically from the change of occupancy by a fire barrier or fire wall. 43 | IEBC 1101.2 Creation or Extension of Nonconformity. | Amend section in its entirety and delete the exception to read as follows: 1101.2: Creation or extension of nonconformity. An addition shall not create or extend any nonconformity in the existing building to which the addition is being made. 44 | IEBC 1103.3 Flood Hazard Areas. | Delete this section. 45 | IEBC 1201.4 Flood Hazard Areas. | Delete this section. 46 | IEBC 1204.4 Occupancy Separation. | Delete this section. 47 | IEBC 1301.1.2 Compliance With Other Codes. | Amend section in its entirety to read as follows: 1301.1.2: Compliance with other codes. Buildings that are evaluated in accordance with this section shall comply with the International Fire Code. 48 | IEBC 1303.1.3 Compliance with Flood Hazard Provisions. | Delete this section. 49 | IEBC 1402.6 Flood Hazard Areas. | Delete this section. 50 | IEBC [F] 1502.1 Site Safety Plan. | Amend the second sentence in the section to read as follows: [F] Section 1502.1: Site safety plan. * * * The plan shall be submitted and approved by the Fire Department before a building permit is issued. * * * [Remainder of Existing text remains] 51 | IEBC [F] 1502.3.1 Violations. | Amend section in its entirety to read as follows: [F] Section 1502.3.1: Violations. Failure to properly conduct, document and maintain documentation required by this section shall constitute an unlawful act in accordance with Section 113.1 and shall result in the issuance of a notice of violation, by the Fire code official, to the site safety director. Upon the third offense, the Fire code official, based on their findings, shall request a stop work order enforcement be implemented to the code official in accordance with Section 114, and work shall not resume until satisfactory assurances of future compliance have been presented to and approved by the code official. 52 | IEBC [F] 1512.1 When required. | Amend section in its entirety to read as follows: [F] 1512.1 When required. An approved water supply for fire protection, either temporary or permanent, shall be made available as soon as combustible material arrives on the site or as determined by the code official. The water supply design and the timing of the water supply installation relative to building construction shall comply with the adopted Fire Code. 53 | IEBC [F] 1512.2 Combustible Building Materials. | Delete this section. 54 | IEBC [F] 1512.3 Vertical Construction of Types III, IV, and V Construction. | Delete this section. 55 | IEBC [F] 1512.4 Vertical Construction, of Types I and II Construction. | Delete this section. 56 | IEBC [F] 1512.5 Standpipe Supply. | Delete this section.
(Ord. No. 4758, § 2(Exh. A), 2-3-20; Ord. No. 4801, § 2(Exh. D), 9-21-20; Ord. No. 4894, § 7(Exh. F), 9-7-21; Ord. No. 5061, § 3(Exh. B), 9-5-23; Ord. No. 5244, § 2(Exh. A), 5-18-26)
Ask a question about Mesquite law
Corpus searches the Mesquite sections it holds and shows the ones that match, with their citations. Free, no sign-in.
