§ 5-531 — Local Amendments to the International Fuel Gas Code, 2024 Edition

Code of the City of Mesquite, Texas (Supp. No. 71: codified through Ordinance No. 5259, enacted July 20, 2026) · Mesquite City Code § 5-531

Corpus is an independent public-information project, not the official City of Mesquite website. Stable reference: corpuslaw.us/code/e4a8d5c7-df3d-48c8-9420-3ce398342360

Sec. 5-531. - Local Amendments to the International Fuel Gas Code, 2024 Edition.

(a) Specific code provisions. Amendments included in this section are intended to be specific code provisions. If there is a conflict between a provision in the published International Fuel Gas Code (I.F.G.C.), 2024 Edition, and this section, the specific provisions of this section shall control. (b) Table of the local amendments. The following table contains the local amendments to the I.F.G.C., 2024 Edition. (1) Table Legend. a. Column 1: Item Reference Number b. Column 2: Related I.F.G.C. Code Section Number and Title c. Column 3: Local Amendment to I.F.G.C. d. (…): Dots (…) (i.e., an ellipsis) indicate the omission of intact and unchanged text which has not been reproduced for efficiency purposes. It is intended that the text in the I.F.G.C., not set forth in this section and instead denoted by dots (…), shall remain intact and unchanged from the language existing prior to adoption of this section. e. ( * * * ): Asterisks ( * * * ) indicate the omission of intact and unchanged text which has not been reproduced for efficiency purposes. It is intended that the text in the I.F.G.C., not set forth in this section and instead denoted by asterisks ( * * * ), shall remain intact and unchanged from the language existing prior to adoption of this section. (2) TABLE OF LOCAL AMENDMENTS TO THE 2024 INTERNATIONAL FUEL GAS CODE No. | IFGC Code Section No. Title | Local Amendment to IFGC 01 | IFGC 101.1 Title. | Amend section in its entirety to read as follows: 101.1: Title. These regulations shall be known as the Fuel Gas Code of the City of Mesquite, Texas, ("Mesquite Fuel Gas Code") and may hereinafter be referred to as "this code." 02 | IFGC 102.2 Existing Installations. | Add an exception to read as follows: 102.2: Existing installations. * * * Exception: Existing dwelling units shall comply with Section 621.2 (Prohibited use). 03 | IFGC 102.8 Referenced Codes and Standards. | Amend section in its entirety to read as follows: 102.8: Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 8 and such codes, when specifically adopted, and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.8.1 and 102.8.2. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the National Electrical Code shall mean the National Electrical Code as adopted. Exception: Where enforcement of a code provision would violate the conditions of the listing of the equipment or appliance, the conditions of the listing and the manufacturer's installation instructions shall apply. 04 | IFGC 105.1.1 Annual Permit. | Delete this section. 05 | IFGC 105.1.2 Annual Permit Records. | Delete this section. 06 | IFGC 105.3.1 Time Limitation of Application. | Amend section in its entirety to read as follows: 105.3.1: Time limitation of application. An application for a permit for any proposed work shall be deemed to have been abandoned 45-days after the date of filing, unless such application has been pursued in good faith or a permit has been issued; except that the Building Official is authorized to grant one or more extensions of time for additional periods not exceeding 45-days each. The extension shall be requested in writing and justifiable cause demonstrated. 07 | IFGC 105.5.3 Expiration. | Amend section in its entirety to read as follows: 105.5.3: Expiration. Every permit issued shall expire and become null and void if (i) the permittee fails to commence work on the site authorized by such permit within 30-days after its issuance, or (ii) the permittee fails to have the work authorized on the site by such permit inspected during any 90-day period after the work has commenced. It shall be unlawful to commence or recommence work after a permit expires without obtaining a new permit or receiving on extension from the Building Official. The Building Official is authorized to grant, in writing, one or more extensions of time, for periods not more than 90-days each. The extension shall be requested in writing and justifiable cause demonstrated. 08 | IFGC 105.5.4 Extension. | Delete this section. 09 | IFGC 105.5.7 Posting of Permit. | Delete this section. 10 | IFGC 108.2 Schedule of Permit Fees. | Amend by adding a sentence [after the first and only sentence of the section] to read as follows: 108.2: Schedule of permit fees. * * * See Mesquite City Code, Appendix D - Comprehensive Fee Schedule, for applicable fees. 11 | IFGC 108.6 Refunds. | Amend section in its entirety to read as follows: 108.6: Refunds. In the case where a fee was paid or collected erroneously, the Building Official shall authorize a one hundred percent (100%) refund of said fee. In the case where a fee was paid or collected and when no work was performed under a permit issued in accordance with this Code, the Building Official shall authorize a partial refund, of not more than eighty percent (80%) of the permit fee, in accordance with this Section. The Building Official shall not authorize refunding of any fee paid except on written request filed by the original permittee not later than 180-days from the date of fee payment. 12 | IFGC Section 112: Appeals. | Amend title and section in its entirety to read as follows: SECTION 112: APPEALS 112.1: General. Except as otherwise provided, any person shall have the right to appeal an administrative decision of the Building Official, Fire Official, or any other City official to the Building Standards Board, when said decision is relative to the application, enforcement, or interpretation of this Code. The Building Standards Board is established in Mesquite City Code, Chapter 20, Article IV, Division 4 (Building Standards Board). The process and procedures for appealing an administrative decision are set forth in Chapter 5, Article XIII (Appeals of Administrative Decisions to Building Standards Board). Appeal of an Administrative Decision relative to a Certificate of Occupancy: When an appeal of an administrative decision is relative to a Certificate of Occupancy the appeal shall be to the Board of Adjustment for its denial, revocation, suspension, or otherwise (in accordance with Mesquite Zoning Ordinance, Part 5, 5-100, Section 5-106 (Certificate of Occupancy)). The process and procedures for appealing an administrative decision relative to a Certificate of Occupancy, or any other administrative decision made under the Mesquite Zoning Ordinance, are set forth in Mesquite Zoning Ordinance, Part 5, 5-200, Section 5-210 (Appeals of Administrative Decisions to Board of Adjustment). 13 | IFGC 113.1 Unlawful Acts. | Amend section in its entirety to read as follows: 113.1: Unlawful acts. It shall be unlawful for any person, firm, corporation, or entity to erect, construct, alter, extend, repair, move, remove, demolish, or occupy any building, structure, or equipment regulated by this code, or cause same to be done, in conflict with, or in violation of, any of the provisions of this code. 14 | IFGC 113.2 Notice of Violation. | Amend section in its entirety to read as follows: 113.2: Notice of violation. The Building Official is authorized to serve a notice of violation or order on the owner of the premises, or any person, firm, corporation, or other entity responsible for the erection, construction, alteration, extension, repair, moving, removal, demolition, or occupancy of a building or structure, in violation of the provisions of this code, or in violation of a permit or certificate issued under the provisions of this code. Such order may direct the discontinuance of the illegal action or condition and the abatement of the violation. 15 | IFGC 113.3 Prosecution of Violation. | Amend section in its entirety to read as follows: 113.3 Prosecution of Violation. Failure to promptly comply with notice of violation issued by the building official shall constitute a separate violation of this code and may be prosecuted as such by the City. This section shall not be construed as requiring notification, or any other condition, to any proceeding seeking to address any violation of the provisions of this code. 16 | IFGC 113.4 Violation Penalties. | Amend section in its entirety to read as follows: 113.4 Violation penalties. Any person who violates a provision of this code, or fails to comply with any of the requirements thereof, or who erects, constructs, alters or repairs a building or structure in violation of the approved construction documents or directive of the building official, or of a permit or certificate issue under the provisions of this code shall be subject to penalties as prescribed by law and herein in this Article. Nothing in this code shall be construed to interfere, inhibit, or otherwise affect the pursuit of legal remedies or proceedings to restrain, correct, abate, or otherwise address any violation of this code, or to remove or terminate unlawful occupancy of a premises in violation of the provisions of this code. 17 | IFGC Section 202: General Definitions | Amend section by changing the definition for "Code Official" to read as follows: CODE OFFICIAL. The Building Official, or other authority designated by the Building Official, charged with the administration and enforcement of this Code. 18 | IFGC 306.3 Appliances In Attics. | Amend section in its entirety to read as follows: 306.3: Appliances in attics. Attics containing appliances shall be provided with an opening and unobstructed passageway large enough to allow removal of the largest appliance. The passageway shall be not less than 30 inches (762 mm) high and 22 inches (599 mm) wide and to more than 20 feet (6096 mm) in length measured along the centerline of the passageway from the opening to the appliance. The passageway shall have continuous solid flooring not less than 24 inches (610 mm) wide. A level service space not less than 30 inches (762 mm) deep and 30 inches (762 mm) wide shall be present at the front or service side of the appliance. The clear access opening dimensions shall be not less than 20 inches by 30 inches (508 mm by 762 mm), and large enough to allow removal of the largest appliance. As a minimum access to the attic space shall be provided by one of the following: 1. A permanent Stair. 2. A pull-down stair with a minimum 300 lb (136 kg) capacity. 3. An access door from an upper floor level. Exceptions: 1.The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening with the approval of the code official. 2.Where the passageway is unobstructed and not less than 6 feet (1829 mm) high and 22 inches (559 mm) wide for its entire length, the passageway shall be not greater than 50 feet (15,250 mm) in length. 19 | IFGC 306.5.1 Sloped roofs | 306.5.1; change to read as follows: [M] 306.5.1: Sloped roofs. Where appliances, equipment, fans or other components that require service are installed on a roof having a slope of 3 units vertical in 12 units horizontal (25-percent slope) or greater and having an edge more than 30 inches (762 mm) above grade at such edge, a catwalk at least 16 inches in width with substantial cleats spaced not more than 16 inches apart shall be provided from the roof access to a level platform at the appliance. The level platform shall be provided on each side of the appliance to which access is required for service, repair or maintenance. The platform shall be not less than 30 inches (762 mm) in any dimension and shall be provided with guards. The guards shall extend not less than 42 inches (1067 mm) above the platform, shall be constructed so as to prevent the passage of a 21-inch-diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the International Building Code. * * * [Remainder of text unchanged]. 20 | IFGC 401.5 Identification. | Amend section by adding a second paragraph to read as follows: 401.5: Identification. * * * Both ends of each section of medium pressure gas piping shall identify its operating gas pressure with an approved tag. The tags are to be composed of aluminum or stainless steel and the following wording shall be stamped into the tag: "WARNING 1/2 to 5 psi gas pressure Do Not Remove" 21 | IFGC 404.12 Minimum Burial Depth. | Amend section in its entirety to read as follows: 404.12: Minimum burial depth. Underground piping systems shall be installed a minimum depth of 18 inches (458 mm) top of pipe below grade. 22 | IFGC 406.4 Test Pressure Measurements. | Amend section in its entirety to read as follows: 406.4: Test pressure measurements. Test pressure shall be measured with a monometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure. Spring type gauges do not meet the requirement of a calibrated gauge. 23 | IFGC 406.4.1 Test pressure. | Amend section in its entirety to read as follows: 406.4.1 Test pressure. The test pressure to be used shall be no less than 3 psig (20 kPa gauge), or at the discretion of the Code Official, the piping and valves may be tested at a pressure of at least six (6) inches (152 mm) of mercury, measured with a manometer or slope gauge, For tests requiring a pressure of 3 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one half inches (3 ½"), a set hand, 1/10 pound incrementation and pressure range not to exceed 15 psi for tests requiring a pressure of 3 psig. For tests requiring a pressure of 10 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one-half inches (3 ½"), a set hand, a minimum of 2/10 pound incrementation and a pressure range not to exceed 50 psi. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa) (1/2 psi) and less than 200 inches of water column pressure (52.2 kPa) (7.5 psi), the test pressure shall not be less than ten (10) pounds per square inch (69.6 kPa). For piping carrying gas at a pressure that exceeds 200 inches of water column (52.2 kPa) (7.5 psi), the test pressure shall be not less than one and one-half times the proposed maximum working pressure. Diaphragm gauges used for testing must display a current calibration and be in good working condition. The appropriate test must be applied to the diaphragm gauge used for testing. 24 | IFGC 409.1.4 Valves in CSST Installations. | Add new section 409.1.4 to read as follows: 409.1.4: Valves in CSST installations. Shutoff valves installed with corrugated stainless steel (CSST) piping systems shall be supported with an approved termination fitting, or equivalent support, suitable for the size of the valves, of adequate strength and quality, and located at intervals so as to prevent or damp out excessive vibration but in no case greater than 12-inches from the center of the valve. Supports shall be installed so as not to interfere with the free expansion and contraction of the system's piping, fittings, and valves between anchors. All valves and supports shall be designed and installed so they will not be disengaged by movement of the supporting piping. 25 | IFGC 410.1 Pressure Regulators. | Add a second paragraph and exception to read as follows: 410.1: Pressure regulators. * * * Access to regulators shall comply with the requirements for access to appliances as specified in Section 306. Exception: A passageway or level service space is not required when the regulator is capable of being serviced and removed through the required attic opening. 26 | IFGC 621.2 Prohibited Use. | Add exception to read as follows: 621.2: Prohibited use. One or more unvented room heaters shall not be used as the sole source of comfort heating in a dwelling unit. Exception: Existing approved unvented heaters may continue to be used in dwelling units, in accordance with the code provisions in effect when installed, when approved by the Code Official unless an unsafe condition is determined to exist as described in Section 108.7.

(Ord. No. 4801, § 2(Exh. I), 9-21-20; Ord. No. 4894, § 7(Exh. F), 9-7-21; Ord. No. 5061, § 3(Exh. B), 9-5-23; Ord. No. 5245, § 2(Exh. A), 5-18-26)

Ask a question about Mesquite law

Corpus searches the Mesquite sections it holds and shows the ones that match, with their citations. Free, no sign-in.