§ 5-831 — Local Amendments to the International Energy Conservation Code, 2024 Edition

Code of the City of Mesquite, Texas (Supp. No. 71: codified through Ordinance No. 5259, enacted July 20, 2026) · Mesquite City Code § 5-831

Corpus is an independent public-information project, not the official City of Mesquite website. Stable reference: corpuslaw.us/code/9aa1a846-f073-433b-8b96-c462d3a594ad

Sec. 5-831. - Local Amendments to the International Energy Conservation Code, 2024 Edition.

(a) Specific code provisions. Amendments included in this section are intended to be specific code provisions. If there is a conflict between a provision in the published International Energy Conservation Code (I.E.C.C.), 2024 Edition, and this section, the specific provisions of this section shall control. (b) Table of the local amendments. The following table contains the local amendments to the I.E.C.C., 2024 Edition. (1) Table Legend. a. Column 1: Item Reference Number b. Column 2: Related I.E.C.C. Code Section Number and Title c. Column 3: Local Amendment to I.E.C.C. d. (…): Dots (…) (i.e., an ellipsis) indicate the omission of intact and unchanged text which has not been reproduced for efficiency purposes. It is intended that the text in the I.E.C.C., not set forth in this section and instead denoted by dots (…), shall remain intact and unchanged from the language existing prior to adoption of this section. e. ( * * * ): Asterisks ( * * * ) indicate the omission of intact and unchanged text which has not been reproduced for efficiency purposes. It is intended that the text in the I.E.C.C., not set forth in this section and instead denoted by asterisks ( * * * ), shall remain intact and unchanged from the language existing prior to adoption of this section. (2) TABLE OF LOCAL AMENDMENTS TO THE 2024 INTERNATIONAL ENERGY CONSERVATION CODE No. | IECC Code Section No. Title | Local Amendment to IECC 01 | IECC Chapter [CE] 1: C101.1 Title. | Amend section in its entirety to read as follows: C101.1: Title. These regulations shall be known as the Energy Conservation Code of the City of Mesquite, Texas, ("Mesquite Energy Conservation Code") and may hereinafter be referred to as "this code." 02 | IECC Chapter [RE] 1: R101.1 Title. | Amend section in its entirety to read as follows: R101.1 Title. These regulations shall be known as the Energy Conservation Code of the City of Mesquite, Texas, ("Mesquite Energy Conservation Code") and may hereinafter be referred to as "this code." 03 | IECC Chapter [CE] 1: C104.1.2 Alternative Compliance. | Add new section C104.1.2 to read as follows: C104.1.2: Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the Code Official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. 04 | IECC Chapter [RE] 1: R104.1.2 (N1101.4.1) Alternative Compliance. | Add new R104.1.2 (N1101.4.1) to read as follows: R104.1.2 (N1101.4.1): Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the Code Official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. Regardless of the program or the path to compliance, each 1- and 2-family dwelling shall be tested for air and duct leakage as prescribed in Section R402.5.1.2 (N1102. 5.1.2) and R403.3.7 (N1103.3.7) respectively. 05 | IECC Chapter [CE] 1: C106.2 Schedule of Permit Fees. | Amend by adding a sentence [after the first and only sentence of the section] to read as follows: C106.2: Schedule of permit fees. * * * See Mesquite City Code, Appendix D - Comprehensive Fee Schedule, for applicable fees. 06 | IECC Chapter [RE] 1: R106.2 Schedule of Permit Fees. | Amend by adding a sentence [after the first and only sentence of the section] to read as follows: R106.2: Schedule of permit fees. * * * See Mesquite City Code, Appendix D - Comprehensive Fee Schedule, for applicable fees. 07 | IECC Chapter [CE] 1: C106.6 Refunds. | Amend section in its entirety to read as follows: C106.6: Refunds. In the case where a fee was paid or collected erroneously, the Building Official shall authorize a one hundred percent (100%) refund of said fee. In the case where a fee was paid or collected and when no work was performed under a permit issued in accordance with this Code, the Building Official Shall authorize a partial refund, of not more than eighty percent (80%) of the permit fee, in accordance with this Section. The Building Official shall not authorize refunding of any fee paid except on written request filed by the original permittee not later than 180-days from the date of fee payment. 08 | IECC Chapter [RE] 1: R106.6 Refunds. | Amend section in its entirety to read as follows: R106.6: Refunds. In the case where a fee was paid or collected erroneously, the Building Official shall authorize a one hundred percent (100%) refund of said fee. In the case where a fee was paid or collected and when no work was performed under a permit issued in accordance with this Code, the Building Official shall authorize a partial refund, of not more than eighty percent (80%) of the permit fee, in accordance with this Section. The Building Official shall not authorize refunding of any fee paid except on written request filed by the original permittee not later than 180-days from the date of fee payment. [The remainder of this page is intentionally left blank.] 09 | IECC Chapter [CE] 1: SECTION C109 Appeals. | Amend title and section in its entirety to read as follows: SECTION C109 APPEALS C109.1: General. Except as otherwise provided, any person shall have the right to appeal an administrative decision of the Building Official, Fire Official, or any other City official to the Building Standards Board, when said decision is relative to the application, enforcement, or interpretation of this Code. The Building Standards Board is established in Mesquite City Code, Chapter 20, Article IV, Division 4 (Building Standards Board). The process and procedures for appealing an administrative decision are set forth in Chapter 5, Article XIII (Appeals of Administrative Decisions to Building Standards Board). Appeal of an Administrative Decision relative to a Certificate of Occupancy: When an appeal of an administrative decision is relative to a Certificate of Occupancy the appeal shall be to the Board of Adjustment for its denial, revocation, suspension, or otherwise (in accordance with Mesquite Zoning Ordinance, Part 5, 5-100, Section 5-106 (Certificate of Occupancy)). The process and procedures for appealing an administrative decision relative to a Certificate of Occupancy, or any other administrative decision made under the Mesquite Zoning Ordinance, are set forth in Mesquite Zoning Ordinance, Part 5, 5-200, Section 5-210 (Appeals of Administrative Decisions to Board of Adjustment). 10 | IECC Chapter [CE] 2: C202 General Definitions. | Amend section by changing the definition for "Code Official" to read as follows: CODE OFFICIAL. The Building Official, or other authority designated by the Building Official, charged with the administration and enforcement of this Code. 11 | IECC Chapter [RE] 1: R202 General Definitions. | Amend section by changing the definition for "Code Official" to read as follows: CODE OFFICIAL. The Building Official, or other authority designated by the Building Official, charged with the administration and enforcement of this Code. [The remainder of this page is intentionally left blank.] 12 | IECC Chapter [CE] 4: C403.7.4.1 Nontransient Dwelling Units. | Amend section and add #5 exceptions to read as follows. C403.7.4.1: Nontransient dwelling units. Nontransient dwelling units shall be provided with outdoor air energy recovery ventilation systems complying with not less than one of the following: 1. The system shall have an enthalpy recovery ratio of not less than 50 percent at cooling design condition and not less than 60 percent at heating design condition. 2. The system shall have a sensible recovery efficiency (SRE) that is not less than 65 percent at 32°F (0°C) and in Climate Zones 0A, 1A, 2A and 3A shall have a net moisture transfer (NMT) that is not less than 40 percent at 95°F (35°C). SRE and NMT shall be determined from a listed value or from interpolation of listed values at an airflow not less than the design airflow, based on testing in accordance with CAN/CSA C439. Exceptions: 1. Nontransient dwelling units in Climate Zone 3C. 2. Nontransient dwelling units with not more than 500 square feet (46 m2) of conditioned floor area in Climate Zones 0, 1, 2, 3, 4C and 5C. 3. Enthalpy recovery ratio requirements at heating design condition in Climate Zones 0, 1 and 2. 4. Enthalpy recovery ratio requirements at cooling design condition in Climate Zones 4, 5, 6, 7 and 8. 5. Dwelling units using ventilation systems per the Fan Efficacy Table in R406, shall be considered in compliance. 13 | IECC Chapter [CE] 4: C405.2.10 Sleeping Unit and Dwelling Unit Lighting and Switched Receptacle Controls. | Delete this section. 14 | IECC Chapter [RE] 1: R105.2.2 Solar Ready System. | Delete this section. 15 | IECC Chapter [RE] 1: R106.3 Permit Valuation. | Delete this section. 16 | IECC Chapter [RE] 2: R202 (N1101.6) General Definitions | Add definition for "Dynamic Glazing" as follows: DYNAMIC GLAZING. Any fenestration product that has the fully reversible ability to change its performance properties, including U-factor, solar heat gain coefficient (SHGC), or visible transmittance (VT). 17 | IECC Chapter [RE] 4: R401.2.1 Prescriptive Compliance Option. | Amend section to delete the reference to R408 to now read as follows: R401.2.1: Prescriptive Compliance Option. The Prescriptive Compliance Option requires compliance with Sections R401 through R404. 18 | IECC Chapter [RE] 4: Table 402.1.2 (1102.1.2) MAXIMUM ASSEMBLY U-FACTOR AND FENESTRATION REQUIREMENTS | Amend table as follows. TABLE R402.1.2 (N1102.1.2) - MAXIMUM ASSEMBLY U-FACTOR AND FENESTRATION REQUIREMENTS. [Portions of table not shown remain unchanged.] [image omitted; see the official code] f. Air-impermeable insulation located at the attic roofline but below the roof deck may be used if mechanical equipment and air distribution system are located entirely within the building thermal envelope. "Air-impermeable" shall be defined as having an air permeance not exceeding 0.02 L/s-m 2 at 75 Pa pressure differential tested according to ASTM E 2178 or ASTM E 283. 19 | IECC Chapter [RE] 4: Table 402.1.3 (1102.1.3) INSULATION MINIMUM R-VALUES AND FENESTRATION REQUIREMENTS BY COMPONENT | Amend table as follows. TABLE R402.1.3 (N1102.1.3) - INSULATION MINIMUM R-VALUES AND FENESTRATION REQUIREMENTS BY COMPONENTa [Portions of table not shown remain unchanged.] [image omitted; see the official code] i. Air-impermeable insulation of R-30&0 or greater located at the attic roofline but below the roof deck may be used if mechanical equipment and air distribution system are located entirely within the building thermal envelope. "Air-impermeable" shall be defined as having an air permeance not exceeding 0.02 L/s-m 2 at 75 Pa pressure differential tested according to ASTM E 2178 or ASTM E 283. 20 | IECC Chapter [RE] 4: R402.2.10 (N1102.2.10) Slab-On-Grade Floors. | Amend section by amending the exception to read as follows: R402.2.10 (N1102.2.10): Slab-on-grade floors. * * * Exception: Slab-edge insulation is not required in jurisdictions designated by the code official as having a moderate to heavy or very heavy termite infestation probability. 21 | IECC Chapter [RE] 4: R402.5.5 (N1102.5.5) Air-Sealed Electrical And Communication Outlet Boxes. | Amend section and add an exception to read as follows: Section R402.5.5 (N1102.5.5): Air-sealed electrical and communication outlet boxes. Air-sealed electrical and communication outlet boxes that penetrated the air barrier of the building thermal envelope shall be caulked, taped, gasketed or otherwise sealed to the air barrier element being penetrated. Air-sealed boxes shall be buried in or surrounded by insulation. Air-sealed boxes shall be tested and marked in accordance with NEMA OS 4. Air-sealed boxes shall be installed in accordance with the manufacturer's instructions. Exception: Boxes may be air-sealed in the field using caulk, tape, gasket or other approved method to prevent air leakage through the box in lieu of NEMA OS 4 boxes. Boxes air-sealed in the field shall be sealed to the air barrier element being penetrated and installed in accordance with manufacturer's instructions. [The remainder of this page is intentionally left blank.] 22 | IECC Chapter [RE] 4: R404.2 (N1104.2) Interior Lighting Controls. | Delete this section. 23 | IECC Chapter [RE] 4: TABLE R405.4.2(1) (N1105.4.2(1)) - SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS | Amend table as follows: TABLE R405.4.2(1) (N1105.4.2(1)) - SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS [image omitted; see the official code] [The remainder of this page is intentionally left blank.] 24 | IECC Chapter [RE] 4: Table R406.5 Maximum Energy Rating Index. | Amend table as follows: TABLE R406.5 (N1106.5) MAXIMUM ENERGY RATING INDEX; amend to read as follows: [image omitted; see the official code]

(Ord. No. 4801, § 2(Exh. K), 9-21-20; Ord. No. 4894, § 7(Exh. F), 9-7-21; Ord. No. 4945, § 2(Exh. A), 3-21-22; Ord. No. 5061, § 3(Exh. B), 9-5-23; Ord. No. 5243, § 2(Exh. A), 5-18-26)

Ask a question about Mesquite law

Corpus searches the Mesquite sections it holds and shows the ones that match, with their citations. Free, no sign-in.