§ 7.5-7 — Service unit determination
Code of the City of Mesquite, Texas (Supp. No. 71: codified through Ordinance No. 5259, enacted July 20, 2026) · Mesquite City Code § 7.5-7
Corpus is an independent public-information project, not the official City of Mesquite website. Stable reference: corpuslaw.us/code/1e0ee24c-3b4a-45ba-b45f-3e34e49e2fd8
Sec. 7.5-7. - Service unit determination.
(a) The number of service units for a new development shall be determined by Table 1, the Service Unit Equivalency Table for Water and Wastewater Facilities, and Table 2, the Land Use/Vehicle Mile Equivalency Table for Roadway Facilities. (b) In determining the number of service units for water and wastewater facilities, the following rules shall apply: (1) Each new freestanding building requires a new water meter, except as provided in Subsection (2). (2) Where a site is redeveloped (clearance and reconstruction), no new LUEs will be attributed to such redevelopment, provided that the water meter is of the same size as the development previously occupying the site. If meter size is increased, the number of LUEs will be based upon the increase in capacity of the meter. (3) Existing buildings or land uses may be expanded using existing meter service. No LUEs will be attributed to such development if the water meter size remains the same. If the meter size is increased, the number of LUEs will be based upon the increase in capacity of the meter. (4) Calculation of the number of service units for water and wastewater impact fees generally shall be the same, except that no LUEs for wastewater impact fees will be attributed to irrigation meters. (5) If an existing structure or use does not require a water meter for water or wastewater service, or does not generate the need for water or wastewater service, no LUEs will be attributable to such use or structure. (6) If a fire demand meter (tap) is purchased for a property, the meter size used to calculate the number of LUEs shall be the dimension of the portion of the fire demand meter which reflects the meter size and would provide only potable service to the property. The reduced meter size shall then be used to calculate the number of LUEs. a. The meter types used to calculate the number of LUEs shall be simple, compound or turbine meters. b. To avoid the use of fire flow volumes for potable usage, the owner of any property for which a fire demand meter is purchased shall be required to execute a restrictive covenant on a form approved by the City Attorney, which covenant shall state that use of the fire demand meter for potable water needs in excess of that determined in establishing the meter size for impact fees shall be cause for collection of additional impact fees up to the actual size of the fire demand meter. Said covenant shall be executed prior to the purchase of the fire demand meter and shall be filed in the deed records of the County. (c) The land use equivalency table may be amended from time to time using the amendment procedure set forth in Section 7.5-17.
(Ord. No. 4366, § 1, 7-6-15; Ord. No. 4756, § 1(Exh. A), 1-21-20)
Ask a question about Mesquite law
Corpus searches the Mesquite sections it holds and shows the ones that match, with their citations. Free, no sign-in.