L. - Improvements required prior to acceptance of subdivision by the City.

(1) Survey monuments. Survey monuments as prescribed hereinabove shall be placed at all corners as required hereinabove. (2) Street and alley improvements. (a) The developer shall prepare or have prepared complete engineering plans of streets, alleys, curbs and gutters, storm sewers and drainage structures, water and sanitary sewer improvements for the area covered by the final plat in accordance with the City of Mesquite Engineering Design Manual. After approval of the plat, plans and specifications, the developer shall cause his contractor to install the facilities in accordance with the approved plans and specifications. The developer shall cause his engineer to design, stake and supervise the construction of such improvements and shall cause his contractor to construct the said improvements in accordance with these regulations. The City Engineer shall inspect the installation of the improvements. Acceptance of the completed improvements by the City will be after receipt of a one-year maintenance bond from each separate contractor in the amount of 10 percent of the contract price, "AS BUILT" plans for each project in accordance with the City of Mesquite Engineering Design Manual, and a letter stating the contractor's compliance with these regulations. (b) Streets and alleys shall be paved in compliance with the City of Mesquite Engineering Design Manual and City of Mesquite Thoroughfare Plan. (3) Storm drainage. An adequate storm sewer system shall be installed in accordance with the City of Mesquite Engineering Design Manual and all subsequent revisions. Areas subject to flood conditions as established by the City of Mesquite will not be considered for development until adequate drainage has been provided. (4) Water. All subdivisions shall be provided with an approved water system designed and constructed in accordance with the City's Water Distribution Plan and City of Mesquite Engineering Design Manual and subsequent revisions. In the corporate limits of the City of Mesquite, all subdivisions shall be connected with the City of Mesquite water supply distribution system unless otherwise approved by the City of Mesquite. (5) Sewer improvements. (a) All subdivisions shall be provided with an approved sewage disposal system designed and constructed in accordance with the City's Sewer Plan and City of Mesquite Engineering Design Manual and subsequent revisions. In the corporate limits of the City of Mesquite, all subdivisions shall be connected with the City of Mesquite sanitary sewer system unless otherwise approved by the City of Mesquite. (b) In locations where sanitary sewers are not available and where there is no immediate prospect for installation of sanitary sewers, then septic tanks of approved type may be installed in conformity with the rules, regulations and ordinances of the City of Mesquite pertaining to public health, provided that in no case shall septic tanks be installed without the express approval and inspection of the City of Mesquite. (6) As built plans. The developer or his engineer shall present the City with as built plans for all paving, drainage structures, water mains and sewer mains in accordance with the City of Mesquite Engineering Design Manual. (7) Engineering plan review fees. In order to defray the administrative costs of review, the Developer shall submit plan review fees with the initial and subsequent engineering plan submissions at the time of submission. See Appendix D for applicable fees. (8) Engineering inspection fee. In order to defray the administrative costs of inspection, the Developer shall submit an engineering inspection fee prior to the release of engineering plans in the amount shown in the current fee schedule as adopted by the City Council. The engineering inspection fee shall cover site improvements including but not limited to streets, alleys, median improvements, water lines, fittings, valves, fire hydrants, RPZs, sanitary sewer lines, lift stations, manholes, storm sewer lines, drainage structures, bridges, culverts, screening walls and retaining walls, but excludes work within the building footprint, concrete and asphalt parking lots, sidewalks, barrier-free ramps, private landscaping and irrigation. (9) Expiration of engineering plans. The acceptance of an administratively complete engineering plan submittal application is considered a permit under Texas Local Government Code, Chapter 245. Said permit shall expire two years after acceptance of administratively complete application unless progress is being made toward completion of the project. If the permit expires, a new engineering plan submittal application will be required under current design standards and ordinances, which shall include submission of additional fees.

(Ord. No. 4704, § 1(Exh. C), 8-19-19)

Ask a question about Mesquite law

Corpus searches the Mesquite sections it holds and shows the ones that match, with their citations. Free, no sign-in.