§ 13-4-5 — Development standards
Municipal Code of the City of Midland, Texas (Supp. No. 1, Update 2: codified through Ordinance No. 10709, enacted February 10, 2026) · Midland Municipal Code § 13-4-5
Corpus is an independent public-information project, not the official City of Midland website. Stable reference: corpuslaw.us/code/d36e4402-3282-4e67-bdb8-58f2158c6205
Sec. 13-4-5. - Development standards.
(A) The heliport and helistop and the operation thereof shall comply with all fire safety standards relating to heliports and helistops set out and defined in the National Fire Protection Association Booklet No. 403 (Aircraft Rescue and Fire Fighting Services at Airports and Heliports), published by the National Fire Protection Association, including all subsequent amendments, and as set out and defined in NFPA Booklet Edition 418, "Standard on Rooftop Heliport Construction and Protection," including all subsequent amendments thereto. (B) The use, operation and construction of a heliport or helistop shall comply with the "Heliport Design Guide" No. AC 150/5390-1B, published by the Federal Aviation Administration, dated August 22, 1977, including all subsequent amendments thereto, and with the requirements of FAR Part 77, Section 77.29, "Airport Imaginary Surfaces for Heliports" contained in the Federal Aviation Regulations revised May 16, 1971, including all subsequent amendments thereto. (C) Landing areas shall, as far as practicable, be aligned with regard to prevailing winds and/or air turbulence. (D) The area used for landing shall be surfaced with material that will be free of dust, loose organic or inorganic materials, and particles of concrete which may be blown about by the down-blast of air of the rotor or rotors. (E) Touchdown areas shall be surrounded by a fence or wall at least four feet high and constructed in such a manner as to deflect the horizontal wind velocities caused by the rotation of the rotor blades. (F) In addition, the following safety precautions shall be taken: 1. Rooftop facilities. (a) On all touchdown or landing areas, whether elevated or flush with the roof, provision shall be made for collecting volatile substances which may be spilled in event of any emergency. Separator or clarifier tanks for collecting spilled volatile substances shall be installed under approval and supervision of the Midland fire department. (b) The rooftop shall have at least two conforming exits and they shall be located in such a manner as to permit safe exit from the roof area in the event one of the exits is blocked. (c) A wind-indicating device shall be installed. A flag, banner or similar device shall be acceptable. (d) Two or more wet standpipes shall be provided and equipped with 1½-inch rubber-lined fire hoses not over 100 feet in length. Hoses shall be equipped with combination fog nozzles. Sufficient pressure shall be available to afford a good fog pattern. Hose cabinets or racks shall be located near the separate exits. Standpipe outlets shall be so located that all portions of the roof area shall be within 120 feet of the outlet. (e) Two fire extinguishers of at least 16 BC rating shall be provided, and be located remotely from each other. (f) No rooftop obstructions which may be difficult to see from the air shall be permitted within the required glide slope. (g) Such lights as are installed to illuminate the touchdown pad shall be directed onto the touchdown pad only, and in such a manner that the light rays cannot interfere with the helicopter pilot's vision or with other aircraft flying within the area of the landing facility. (h) No person shall be permitted in the general landing area in any location where any portion of his body will be higher than the touchdown area surface while landing or takeoff operations are underway. (i) An approved means of communication such as a telephone, radio, fire alarm box or signaling device shall be provided adjacent to the landing area. (j) If the roof has no parapet wall, a substantial fence shall be provided around the perimeter of the roof to ensure the safety of all persons. (k) Rooftop facilities shall be built in accordance with the city building code as applicable for structural and fire protective requirements. 2. Ground level helistops and heliports for helicopters. (a) All installed lights shall illuminate and be directed onto the touchdown pad only, and in such a manner that the light rays cannot interfere with the pilot's vision. (b) A wind-indicating device shall be installed. A flag, banner or similar device shall be acceptable. (c) Unauthorized persons shall not be permitted in the general landing area during flight operations. (d) Two fire extinguishers of at least 16 BC rating shall be provided and be located remotely from each other. (e) Where buildings or structures in proximity to the landing area present a fire exposure hazard, there shall be provided at least two 1½-inch wet standpipe outlets equipped with 1½-inch fire hoses, not over 100 feet in length, and a combination fog nozzle. (f) An approved means of communication such as a telephone, radio, fire box or signaling device shall be provided adjacent to the landing area. (G) A detailed site plan shall be submitted showing all safety precautions, parking area layout, landscaping along the street frontages, type and size of aircraft proposed for use and approach and departure lanes. (H) Markings. All markings shall conform to those recommended in said FAA AC 150/5390-1B. (I) Touchdown area. The touchdown area (as opposed to the landing area) for helicopters under 3,500 pounds shall have a minimum dimension of 20 feet by 20 feet. Touchdown areas for helicopters over 3,500 pounds shall be a minimum of 1½ times the diameter of the rotor blades or 40 feet by 40 feet, whichever is greater.
(Ordinance 5801 adopted 8/11/1981)
Ask a question about Midland law
Corpus searches the Midland sections it holds and shows the ones that match, with their citations. Free, no sign-in.