§ 4-2-22 — Wiring methods

Municipal Code of the City of Midland, Texas (Supp. No. 1, Update 2: codified through Ordinance No. 10709, enacted February 10, 2026) · Midland Municipal Code § 4-2-22

Corpus is an independent public-information project, not the official City of Midland website. Stable reference: corpuslaw.us/code/5cbe02da-fc02-4228-badf-8568d0304b65

Sec. 4-2-22. - Wiring methods.

All wiring methods approved by the National Electrical Code are hereby adopted with the following exceptions: (A) No conductor smaller than size number 12 wire shall be permitted in any type of electrical installation that exceeds 100 volts to ground except in control circuits. (B) No aluminum wire conductor smaller than size number one-zero (1/0) shall be used on premises wiring within the corporate limits of the City of Midland, except overhead exterior (aerial) circuits may use aluminum wire conductor that meet National Electrical Code sizing requirements. (C) Branch circuit. All residence branch circuit conductors shall be 20 ampere capacity and shall be protected by 20 ampere circuit breakers or 20 ampere fuses of the tamper-proof type. Larger branch circuit protectors shall be allowed only on special purpose circuits. (D) Future circuits. There shall be a minimum of two three-fourths inch conduit or electrical metallic tubing from lighting panels with 20 or more breaker switches and there shall be a minimum of one three-fourths inch conduit or electrical metallic tubing from lighting panels with less than 20 breaker switches. (E) Residential services. All meter locations shall conform to the latest electric utility provider guidelines and specifications which are hereby adopted, a copy of which is on file with the City Secretary, when such locations are in agreement with the National Electrical Code or the provisions of this Chapter. A single family residential structure and its accessory structures shall be served by a single service. (F) Weather-proof main disconnects shall be installed outside on all new residence and apartments and on service changes to residences and apartments. (G) Not more than six consuming outlets (plugs and lights) on one 20 ampere circuit shall be installed in commercial buildings within the City limits of Midland, except as designed by a State of Texas licensed electrical engineer. Circuits with lighting only shall be installed according to the National Electrical Code. (H) Not less than 24 inches of each conductor shall be left at the service head for connection to the service drops and the neutral conductor shall be permanently identified.

(Ordinance 9926, sec. 1, adopted 5/28/2019)

Ask a question about Midland law

Corpus searches the Midland sections it holds and shows the ones that match, with their citations. Free, no sign-in.