For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4-9-12 — Safe and sanitary maintenance

Municipal Code of the City of Midland, Texas (Supp. No. 1, Update 2: codified through Ordinance No. 10709, enacted February 10, 2026) · Midland Municipal Code § 4-9-12

Corpus is an independent public-information project, not the official City of Midland website. Stable reference: corpuslaw.us/code/dcd17d2e-af89-41e3-a590-7636f0ae997c

Sec. 4-9-12. - Safe and sanitary maintenance.

Every dwelling and dwelling unit, as hereinafter specified, located within the corporate limits of the City of Midland, Texas, shall comply with the following requirements: 4-9-12.1 Foundations. Every foundation shall be so free of holes, cracks, buckling, crumbling and defects as to support adequately the dwelling structure. 4-9-12.2 Floors, exterior walls and roofs. Every floor, exterior wall and roof shall be so free of holes, cracks, and loose, rotten, warped or protruding boards as to protect the occupants of the dwelling or dwelling unit reasonably from weather elements and from danger of collapse. 4-9-12.3 Interior walls and ceilings. Every interior wall and ceiling shall be so free of holes, cracks, loose plaster, loose and baggy wallpaper, defective materials and structural deterioration as to reasonably serve their purpose and as to protect the occupants of the dwelling or dwelling unit from danger of collapse and of fire. 4-9-12.4 Protection of exterior surfaces. All exterior exposed surfaces shall be repaired, coated, treated or sealed so as to protect them from serious deterioration. 4-9-12.5 Windows and doors. Every window and exterior door shall be reasonably water and weather tight and shall be kept in sound working condition and good repair. 4-9-12.6 Stairways and porches. Every inside and outside stairway shall comply with the provisions pertaining to stairways contained in Chapter 4-1, of the building code of the City of Midland, Texas, and every porch and appurtenance thereto shall be maintained in a manner as to present no danger of collapse or injury to the occupants of a dwelling or dwelling unit or to the public. 4-9-12.7 Supplied facilities. Every supplied facility, piece of equipment or utility which is required under the provisions of this Chapter shall be so designed, constructed and installed according to law that it will function safely and effectively and shall be maintained in a safe and sanitary working condition. 4-9-12.8 Plumbing facilities. Every plumbing fixture and water supply, sewer line and waste disposal system shall be properly installed according to law and maintained in safe and sanitary conditions free from defects, leaks and obstructions. 4-9-12.9 Infestation. Every dwelling, dwelling unit and all dwelling premises shall be free of infestation by rodents or vermin. 4-9-12.10 Dwelling premises and accessory structures. All dwelling premises and accessory structures, including fences, shall be maintained in good repair and sanitary condition. All fences shall be constructed and maintained so as to support their own weight. 4-9-12.11 Vertical structural sections. All buildings, including dwellings or dwelling units, where, on a vertical structural section designed as a gravity member, there occurs a lateral displacement which causes the resultant pressure to fall beyond the middle third of the base of such gravity member, it shall cause said section to be considered unsafe and subject to correction or demolition. 4-9-12.12 Walls, vertical and horizontal structural members. All buildings, including dwellings or dwelling units, whose walls, vertical structural members, or horizontal structural members, other than gravity type walls, list, lean, or buckle from their designed position, or show other visual signs of deterioration to such a degree that, in the opinion of the housing standards inspector, an imminent hazard to the building, dwelling or dwelling unit or its/their occupants is present, shall cause said section to be considered unsafe and subject to correction or demolition. 4-9-12.13 Deteriorated supporting members. All buildings, dwellings, or dwelling units which, exclusive of the foundation, show 33 percent or more of damage or deterioration of the supporting member or members, or 50 percent of damage or deterioration of the non-supporting enclosing or outside walls or covering, are hereby declared unfit for human occupation and in violation of this Chapter. 4-9-12.14 Insufficient structural strength. All buildings, dwellings or dwelling units which have improperly distributed loads upon the floors or roofs or in which the same are overloaded, or which have insufficient strength to be reasonably safe for the purpose, substantially as defined by the building code of the City of Midland, Texas, as amended, are hereby declared unfit for human occupation and in violation of this Chapter. 4-9-12.15 Casualty damage. All buildings, dwellings or dwelling units which have been damaged by fire, explosion, wind, vandalism or elements of nature so as to have become dangerous to life, safety, morals or the general health and welfare of the occupants thereof or the people of the City of Midland are hereby declared unfit for human occupation and in violation of this Chapter.

(Ordinance 4357 adopted 11/10/1967)

Ask a question about Midland law

Corpus searches the Midland sections it holds and shows the ones that match, with their citations. Free, no sign-in.