For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-2-16 — Construction and maintenance of physical facilities

Municipal Code of the City of Midland, Texas (Supp. No. 1, Update 2: codified through Ordinance No. 10709, enacted February 10, 2026) · Midland Municipal Code § 8-2-16

Corpus is an independent public-information project, not the official City of Midland website. Stable reference: corpuslaw.us/code/03454755-3d74-4c76-8890-aa55e8405110

Sec. 8-2-16. - Construction and maintenance of physical facilities.

(A) Floor construction. Floors and floor coverings of all food preparation, food service, food storage, and utensil-washing areas, and the floors of all walk-in refrigerating units, dressing rooms, locker rooms, toilet rooms and vestibules shall be constructed of smooth durable material such as stainless steel, terrazzo ceramic or quarry tile, or the equivalent as approved by the Regulatory Authority and shall be maintained in good repair. Sealed concrete and VCT are not acceptable as a floor surface for areas mentioned above. (B) Durable grades of sheet vinyl may be used in dry storage areas. Sealed concrete may be used in walk-in freezer units maintaining a temperature of zero F or below. Nothing in this rule shall prohibit the use of anti-slip floor covering in areas where necessary for safety reason. (C) Floor carpeting. A floor covering such as carpeting or similar material may not be installed as a floor covering in food preparation areas, walk-in refrigerators, warewashing areas, toilet room areas where hand washing lavatories toilets, and urinals are located, refuse storage rooms, or other areas where the floor is subject to grease, moisture, flushing, or spray cleaning methods. If carpeting is installed as a floor covering in areas other than those specified above it shall be: securely attached to the floor with a durable mastic, by using a stretch and tack method, or by another method; and install tightly against the wall under the coving or installed away from the wall with a space between the carpet and the wall and the edges of the carpet secured by metal stripping or some other means. (D) Prohibited floor covering. The use of cardboard, sawdust, wood shavings, peanut hulls, or similar materials as a floor covering is prohibited. (E) Floor drains. Proper installed, trapped floor drains shall be provided in floors that are water flushed for cleaning or that receive discharges of water or other fluid waste from equipment, or in areas where pressure spray methods for cleaning equipment are used. Properly trapped floor drains are required in all restrooms. Such floor drains shall be constructed of stainless steel, terrazzo, ceramic tile, quarry tile or similar material and shall be graded to drain. (F) Mats and duckboards. Mats and duckboards shall be of nonabsorbent, grease resistant materials and of such size, design, and construction as to facilitate their being easily cleaned. Duckboards shall not be used as storage racks. (G) Floor junctures. In all new or extensively remodeled establishments utilizing stainless steel, terrazzo, ceramic tile, quarry tile or similar materials, and where water flush cleaning methods are used, the junctures between walls and floors shall be of the same material. (H) Utility line installation. Exposed utility service lines and pipes shall be installed in a way that does not obstruct or prevent cleaning of the floor. In all new or extensively remodeled establishments, installation of exposed horizontal utility lines and pipes on the floor is prohibited. (I) Maintenance. Walls and ceilings, including doors, windows, skylights and similar closures, shall be maintained clean and in good repair. (J) Construction. The walls, including nonsupporting partitions, wall coverings, and ceilings of walk-in refrigerating units, food preparation areas, dry storage areas, food storage areas, equipment-washing and utensil washing areas, toilet rooms and vestibules shall be light colored, smooth nonabsorbent, and easily cleanable such as FRP (fiberglass reinforced paneling), stainless steel ceramic tile, quarry tile, terrazzo or equivalent approved by the Regulatory Authority. (K) Exposed construction. Studs, joists, and rafters shall not be exposed in those areas listed in paragraph (b) of this subsection. If exposed in other rooms or areas, they shall be finished to provide an easily cleanable surface. (L) Utility line installation. Exposed utility service lines and pipes shall be installed in away that does not obstruct or prevent cleaning of the walls and ceilings. Utility service lines and pipes shall not be unnecessarily exposed on walls or ceilings in those areas listed in paragraph (b) of Sec. 8-7-2 of this rule. (M) Attachments. Light fixtures, vent covers, wall mounted fans, decorative materials, and similar equipment attached to the walls and ceilings shall be easily cleanable and shall be maintained in good repair. (N) Covering material installation. Wall and ceiling materials shall be attached and sealed so as to be easily cleanable.

(Ordinance 7910, sec. 7, adopted 1/11/00)

Ask a question about Midland law

Corpus searches the Midland sections it holds and shows the ones that match, with their citations. Free, no sign-in.