§ 8-9-5 — Definitions
Municipal Code of the City of Midland, Texas (Supp. No. 1, Update 2: codified through Ordinance No. 10709, enacted February 10, 2026) · Midland Municipal Code § 8-9-5
Corpus is an independent public-information project, not the official City of Midland website. Stable reference: corpuslaw.us/code/fca5065d-c965-473d-9258-1f73df890bd8
Sec. 8-9-5. - Definitions.
For the purpose of this Chapter the following definitions shall apply unless the context clearly indicates or requires a different meaning. If a word or term used in this Chapter is not contained in the following list, its definition shall be as shown in the plumbing code found in Chapter 4-3, of the Midland City Code. Other technical terms used shall have the meanings or definitions listed in the latest edition of the Manual of Cross Connection Control published by the Foundation for Cross Connection Control and Hydraulic Research, University of Southern California. Air gap separation means a physical separation between the free-flowing discharge end of a potable water supply pipeline and an open or nonpressure receiving vessel. An approved air gap separation shall be at least double the diameter of the supply pipe measured vertically above the overflow rim of the vessel, and in no case less than one inch (2.54 cm). Atmospheric vacuum breaker (AVB) means a device consisting of a float check, a check seat, and an air inlet port. A shutoff valve immediately upstream may be an integral part of the assembly. The AVB is designed to allow air to enter the downstream water line to prevent backsiphonage. This unit may never be subjected to a backpressure condition or have a downstream shutoff valve, or be installed where it will be in continuous operation for more than 12 hours. Auxiliary water supply means any water supply on or available to the premises other than the purveyor's approved public water supply. These auxiliary waters may include water from another purveyor's public potable water supply or any natural sources, such as, but not limited to, a well, spring, river, stream, used waters, or industrial fluids. These waters may be contaminated or polluted, or they may be objectionable and constitute an unacceptable water source over which the water purveyor does not have sanitary control. Backflow means the undesirable reversal of flow of water or mixtures of water and other liquids, gases, or other substances into the distribution pipes of a potable water supply from any source(s). Backflow prevention assembly means a device or means to prevent backflow into the potable water system, including reduced pressure backflow assemblies, double checkvalve assemblies, atmospheric vacuum breakers, pressure vacuum breaker assemblies or air gap. Backpressure means a pressure higher than the supply pressure, caused by a pump, elevated tank, boiler, air/stream pressure, or any other means, which may cause backflow. Backsiphonage means a form of backflow due to a reduction in system pressure which causes a negative or sub-atmospheric pressure to exist at a site in the water system. Certified backflow prevention technician means a technician certified in writing by the TNRCC as capable and licensed to check, repair and maintain backflow prevention devices. Commercial establishment means any property or location which is used primarily for the manufacture, production, storage, wholesaling or retailing of any good or ware which is or may be placed in the flow of commerce or any property or location which is used primarily for the provision of any service. Commission means the Texas Natural Resource Conservation Commission (TNRCC). Contamination means an impairment of the quality of the public potable water supply or a private potable water supply by the introduction or admission of any foreign substance that degrades the quality and which creates an actual hazard to the public health through poisoning or through the spread of disease by sewage, industrial fluids, or waste. Cross connection means any actual or potential connection or structural arrangement between a public or private water system through which it is possible to introduce any used water, industrial fluids, gas, or substance other than the intended potable water with which the system is supplied; bypass arrangements, jumper connections, removal sections, swivel or changeover devices and other temporary or permanent devices through which or because of which backflow can or may occur. Cross connection survey means a detailed inspection of a location and disposition of the water lines, including, without limitation, establishing water lines on the premises, the existence of cross connections, the availability of auxiliary or used water supplies, the use of or availability of pollutants, contaminants and other liquid, solid or gaseous substances which may be used for stabilization of water supplies and such other processes necessary to determine the degree of hazard. Customer means the person, company or entity contracting with the City of Midland to receive potable water service. Customer's potable water system means that portion of the privately owned potable water system lying between the point of delivery and the point of use. This system will include all pipes, conduits, tanks, receptacles, fixtures, equipment and appurtenances used to produce, convey, store or utilize the potable water. Degree of hazard means the low or high hazard classification that shall be attached to all actual or potential cross connections. (a) Health hazard means an actual or potential threat of contamination of a physical or toxic nature to the public potable water system or the consumer's potable water system that would be a danger to health. (b) High hazard means the classification assigned to an actual or potential cross connection that potentially could allow a substance that may cause illness or death to backflow into the potable water supply. (c) Low hazard means the classification assigned to an actual or potential cross connection that potentially could allow a substance that may be objectionable but not hazardous to one's health to backflow into the potable water supply. (d) Plumbing hazard means an internal or plumbing-type cross connection in a consumer's potable water system that may be either a pollutional or a contamination-type hazard. (e) Pollutional hazard means an actual or potential threat to the physical properties of the water system or the potability of the public or the consumer's potable water system but which would not constitute a health or system hazard, as defined. The maximum degree of intensity of pollution to which the potable water system could be degraded under this definition would cause a nuisance or be aesthetically objectionable or could cause damage to the system or its appurtenances. (f) System hazard means an actual or potential threat of severe danger to the physical properties of the public or consumer's potable water supply or of a pollution or contamination that would have a detrimental effect on the quality of the potable water in the system. Director means the director of utilities of the City of Midland or his authorized representative or designee. Double checkvalve means an assembly composed of two independently acting approved checkvalves, including tightly closing resilient seated shutoff valves located at each end of the assembly and fitted with properly located resilient seated test cocks. This assembly shall only be used to protect against a non-health hazard (i.e., pollutant). Nonpotable water means water that does not comply with the commission's rules and regulations governing drinking water. Nonresidential use means water used by any person other than a residential customer of the water supply and includes all uses not specifically included in "residential uses." Pollution means an impairment of the quality of the public potable water supply to a degree which does not create a hazard to the public health but does adversely and unreasonably affect the aesthetic qualities of such potable water for domestic use. Potable water or water means water which is satisfactory for drinking, culinary, and domestic purposes and meets the requirements of the commission. Pressure vacuum breaker assembly means an assembly containing an independently operating internally loaded checkvalve and an independently operating loaded air inlet valve located on the discharge side of the checkvalve. The assembly is to be equipped with properly located resilient seated test cocks and tightly closing resilient seated shutoff valves attached at each end of the assembly. Public potable water system means any publicly or privately owned water system operated as a public utility under a health permit to supply water for domestic purposes. This system will include all sources, facilities and appurtenances between the source and the point of delivery such as valves, pumps, pipes, conduits, tanks, receptacles, fixtures, equipment and appurtenances used to produce, convey, treat or store potable water for public consumption or use. Reduced pressure backflow prevention assembly shall consist of two independently acting approved checkvalves together with a hydraulically operating, mechanically independent pressure differential relief valve located between the checkvalves and below the first checkvalve. These units are located between two tightly closing resilient seating shutoff valves and are fitted with properly located resilient seated test cocks. Residential use means water used by any residential customer of the water supply and includes single-family dwellings, duplexes, multiplex housing and apartments where the individual units are each on a separate meter, or, in cases where two or more units are served by one meter, the units are full-time dwellings. Service connection means the terminal end of a service connection from the public potable water system, i.e., where the water purveyor loses jurisdiction and sanitary control of the water at its point of delivery to the consumer's water system. If a meter is installed at the end of the service connection, then the service connection shall mean the downstream end of the meter. Used water means any water supplied by a water purveyor from a public water system to a consumer's water system after it passes through the point of delivery and service connection, and is no longer controlled by the water purveyor. Used water shall not be returned to the public potable water system. Utility means City of Midland utilities department. Water purveyor means the utility, private owner, political subdivision or operator of a potable water system connected to the City of Midland's public water supply and supplying water to other water connections.
(Ordinance 7605, sec. 1, adopted 4/22/1997)
Ask a question about Midland law
Corpus searches the Midland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
