Sec. 8-9-8. - Backflow prevention assemblies.
(A) Installation. 1. New installation. (a) New, replacement, or reconditioned backflow prevention assemblies shall be installed in accordance with the currently adopted plumbing code, as amended. (b) Prior to installation, the person must obtain a plumbing permit. (c) Prior to issuance of a certificate of occupancy, a completed test and maintenance report must be submitted to the utility for any connection requiring a testable backflow prevention assembly. Documentation of an approved air gap can be substituted where applicable. 2. High health hazard installations. (a) Only approved air gaps or reduced pressure backflow prevention assemblies can be installed at high health hazard applications. All assemblies must be tested, at a minimum, on an annual basis, or more frequently at the director's discretion. (b) The director may require a secondary device if deemed necessary to protect the public water supply from the failure of or to allow maintenance of the primary cross control device. 3. Other installations. A backflow prevention assembly shall be installed to protect the potable water system from contamination or pollution when such system is connected to any automatic fire protection systems, standpipe systems, or privately owned fire hydrants. (a) A reduced pressure backflow prevention assembly shall be required if chemicals or additives are combined or added to any fire protection system. (b) Installation of a reduced pressure backflow prevention assembly shall be required on temporary water meters connected to the public potable water system unless an approved air gap is authorized. 4. Wholesale customers. Any customer purchasing water for the purpose of resale or distribution shall: (a) Install an air gap separation or a reduced pressure backflow assembly at the service connection, certified for operation upon installation and annually thereafter by a certified backflow prevention assembly technician forwarding the results to the director within ten days; or (b) Implement a plumbing inspection and cross connection control program not less restrictive than that of the City and provide annual program records to the director for review and audit. (c) A reduced pressure backflow prevention assembly shall be required on all carbonating beverage equipment. 5. Government customers. Any premises owned, operated, or occupied by a state, federal, county, city or foreign government or agency refusing to comply with the provisions of this Chapter shall install a reduced pressure backflow prevention assembly at each service connection, being certified and tested for proper operation upon installation and annually thereafter. In those instances where the director deems potential or actual hazard to be deleterious to human health, certified inspections and operational testing shall be required semiannually. 6. Water hauling trucks. Water hauling trucks obtaining water from a connection to the utility's public potable water system shall have an approved air gap separation or a reduced pressure backflow prevention assembly installed permanently on the vehicle and said assembly shall be registered with the utility and certified for operation annually. (B) Existing commercial service connections. 1. The premises owner, customer or the designated representative shall have all testable backflow prevention assemblies which are currently installed certified for operation by a certified backflow prevention technician on an annual basis. If the device has not been certified for operation within the last year, the device must be tested and, if required, repaired, and the documentation submitted to the director within 90 days of the effective date of this Chapter. 2. Any existing connection which meets the definition of high health hazard must be protected by a backflow prevention device as required by (A) of this Section within 180 days of the effective date of this Chapter unless the director determines that circumstances exist which require installation within a shorter timeframe. 3. Installation of backflow prevention devices against nonhigh health hazard cross connections at existing facilities must be provided on a schedule determined by the director.
(Ordinance 7605, sec. 1, adopted 4/22/1997)
Ask a question about Midland law
Corpus searches the Midland sections it holds and shows the ones that match, with their citations. Free, no sign-in.