§ 10-3-93 — General design requirement
Code of Ordinances, City of Odessa, Texas (Includes legislation through Ord. No. 2026-22 adopted August 11, 2026) · Odessa City Code § 10-3-93
Corpus is an independent public-information project, not the official City of Odessa website. Stable reference: corpuslaw.us/code/3cf1146d-305e-4941-b23a-95fb6debe639
§ 10-3-93: General design requirement.
(a) The purpose of this section is to establish standard criteria, principles, procedures and practices for design of storm drainage facilities. (1) The design factors, formulas, graphs and procedures presented or referred to herein are intended for use as engineering guides in the design of drainage facilities and in the solution of drainage problems involving the quantity, method of collection, transportation and disposal of stormwater. (2) Methods of design other than those indicated or referred to herein may be considered where experience clearly indicates they are preferable; however, these deviations shall not be attempted until approval has been obtained from the city engineer. (3) The methods outlined or referred to herein include accepted principles of surface drainage engineering and should be a working supplement to basic design information obtainable from textbooks and publications on drainage. (b) Determination of design discharge. The two methods acceptable for use in the city are: (1) Rational method to be used on small watersheds of 1,000 acres or less. (A) Q = CiA, in which: (i) Q is the peak runoff rate in cubic feet per second (cfs). Actually, Q is in units of inches per hour per acre; since this rate is in/hr/ac differs from cfs by less than one percent, the more common cfs is used. (ii) C is a runoff coefficient depending on characteristics of the drainage area. (iii) i is the average rainfall intensity in inches per hour (in/hr). (B) The rational method is based on the following assumptions: (i) The peak rate of runoff at any point is a direct function of the average rainfall intensity during the time of concentration to that point. (ii) The frequency of the peak discharge is the same as the frequency of the average rainfall intensity. (iii) The time of concentration is the time required for runoff to become established and flow from the most remote (remote in time, not necessarily distance) part of the drainage area to the point under design. (2) Unit hydrograph techniques may be used for areas greater than 1,000 acres. The city engineer shall approve the technique and the data to be used for the determination of the design discharge prior to the calculations being completed. A complete set of all detail calculations must be submitted to the city engineer for approval prior to completion of the plans for the drainage system. (c) Drainage area. (1) Area of the watershed shall be determined using approved engineering methods. (2) Outline of drainage areas must follow natural drainage features in nonurbanized areas. Consideration shall be given to man-made features in urbanized areas. (d) Runoff coefficients. (1) Storm drainage shall be designed for ultimate development of the watershed and, therefore, runoff coefficients used shall consider these fully developed conditions. Master plans, zoning maps and land use plans shall be used to determine the ultimate development. (2) Table I gives values for runoff coefficients that shall be used in the determination of stormwater runoff. Table I. Runoff Coefficient “C” Retail or Commercial Areas | 0.90 Industrial Areas | 0.70 Residential Areas | 0.50 Park or Open Space Areas | 0.30 (e) Rainfall intensity - duration - frequency curves for this area have been developed using the most current data available. These curves are as published in the drainage criteria manual for the city, which data is approved and incorporated herein by reference. A copy of these curves is on file with the director of public works and is available for inspection. (f) Roughness coefficients “n” have been determined for the city. table II shall be used when assigning values for “n.” Table II. Computation of Composite Roughness Coefficient For Excavated and Natural ChannelsN = (n0 + n1 + n2 + n3 + n4) m Channel Conditions | Value Material involved - n0 | Earth | 0.020 Rockcut | 0.025 Fine Gravel | 0.024 Coarse Gravel | 0.028 Degree of irregularity - n1 | Smooth | 0.000 Minor | 0.005 Moderate | 0.010 Severe | 0.020 Variation of channel cross section - n2 | Gradual | 0.000 Alternating Occasionally | 0.005 Alternating Frequently | 0.010–0.015 Relative effect of obstructions - n3 | Negligible | 0.000 Minor | 0.010–0.015 Appreciable | 0.020–0.030 Severe | 0.040–0.060 Vegetation - n4 | Low | 0.005–0.010 Medium | 0.010–0.025 High | 0.025–0.050 Very High | 0.050–0.100 Degree of meandering - m | Minor | 1.000–1.200 Appreciable | 1.200–1.500 Severe | 1.500 Roughness Coefficient for Line Channels Concrete - n = 0.017 Rubble Rip Rap - n = 0.022 Open Channel Hydraulics Line - Ven Te Chow, Ph.D. (g) Time of concentration. (1) Time of concentration shall be calculated for the watershed under consideration. (2) No time of concentration less than 15 minutes shall be used.
( Ordinance 2018-20 adopted 5/8/18 )
Ask a question about Odessa law
Corpus searches the Odessa sections it holds and shows the ones that match, with their citations. Free, no sign-in.
